The viveroo free is a flush-mount box designed to hold various models of iPad, including iPad mini, iPad 9.7 inch, Air (before 2020), iPad Air 2, iPad Pro 9.7 inch, iPad 10.2 inch, Pro 10.5 inch, iPad Pro 11 inch, Air (from 2020), and iPad Pro 12.9 inch (from 2018). It comes with an installation guide Inwall, free flush-mount box with installation disc, incl. integrated level, a power supply unit (IN: 100-240 Vac, 50/60 Hz, OUT: 5,2 Vdc) or USB Power Adapter USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W, and an elongated hole of 68x139mm. The electrical operation of the viveroo free is only permitted in connection with the viveroo free MountingSet and power supply and cable included in the MountingSet.

Product Usage Instructions

Before installing the viveroo free, it is important to read the assembly instructions included carefully. Also, read the user manual completely before using your viveroo free. The viveroo free and all mounting sets are intended for use in enclosed and dry living spaces without extensive dust, etc. Installation, service or repairs, if necessary, may only be performed by authorized persons.
The maximum altitude is 2.000m.

The installer is responsible for selecting the proper mounting location and safe installation of viveroo free. This also applies to installation in movable parts such as doors. The installer is responsible for performing and documenting all necessary safety tests. All electrical installation work may only be conducted by authorized, trained electricians, always adhering to the general rules and regulations applying to electrical installation.

Should it become apparent that safe operation of viveroo free is not assured, then viveroo free must immediately be taken out of service and secured against potential misuse. If the viveroo free functions are limited, blocked or disabled, if an unusual odor is present, if noises such as scratching are audible or damage is visible, safe operation can no longer be guaranteed.

To install the viveroo free, follow the below steps:

  • Step 1: The viveroo free can be installed either in portrait or landscape position. It is your choice.
  • Step 2: Follow the instructions and recommendations to ensure proper use and maximum enjoyment. The installer is responsible for performing and documenting all necessary safety tests.

Installation guide

MountingSet Inwall, free

Safety information

Important

Please read the assembly instructions included carefully before installing the MountingSet. Please also read the free user manual completely before using your free. Please follow the instructions and recommendations to ensure proper use and maximum enjoyment.

Safety information

free and all free mounting sets are intended for use in enclosed and dry living spaces.
The following conditions must be provided:

  • Operating temperature between 0° C (32° F) and 35° C (95° F).
  • Relative humidity (during use): 20 % to 90 %, non-condensing.
  • No external environmental influences such as oil, chemicals, salt, extensive dust, etc.

Installation, service or repairs, if necessary, may only be performed by authorized persons.
The maximum altitude is 2.000m.
The installer is responsible for selecting the proper mounting location and safe installation of free. This also applies to installation in movable parts, such as doors. The installer is responsible for performing and documenting all necessary safety tests.
All electrical installation work may only be conducted by authorized, trained electricians, always adhering to the general rules and regulations applying to electrical installation.
Should it become apparent that safe operation of free is not assured, then free must immediately be taken out of service and secured against potential misuse. If the free functions are limited, blocked or disabled, if an unusual odor is present, if noises such as scratching are audible or damage is visible, safe operation can no longer be guaranteed.

Technical Data

Product contents

  • Installation guide Inwall
  • free flush-mount box with installation disc, incl. integrated level
  • Power supply unit (IN: 100-240 Vac, 50/60 Hz, OUT: 5,2 Vdc) or USB Power Adapter USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W

Compatability

Electrical operation of free is permitted only in connection with free MountingSet and power supply and cable included in the MountingSet. Operation of free without a MountingSet will lead to immediate loss of guarantee and warranty

Measurements in millimeter

Measurements design cover free for …

  • … iPad mini 223 x 134
  • … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 267 x 164
  • … iPad 10.2 inch, Pro 10.5 inch 277 x 173
  • … iPad Pro 11 inch, Air (from 2020) 275 x 178
  • … iPad Pro 12.9 inch (from 2018) 332 x 214
    Depth free 16
    Size of opening
    (for flush-mounted box) elongated hole 68×139
    Installation depth
    (for flush-mounted box) 75

Weight in gram

free for …

  • … iPad mini 876
  • … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 924
  • … iPad 10.2 inch, Pro 10.5 inch 952
  • … iPad Pro 11 inch, Air (from 2020) 993
  • … iPad Pro 12.9 inch (from 2018) 1.110

Electrical connections

  • Power supply 100-240 Vac 50-60 Hz
  • Power consumption 12,5Watt – 18Watt, depending on iPad and power supply

Removal from power supply

free may be removed from the power supply via the circuit breaker in the respective rooms.

Technical changes and mistakes are excepted.
Apple, iPad and Lightning are registered trademarks of Apple Inc.

Installation flush-mount box

Step 1

free can be installed either in portrait or landscape position, it is your choice.
For installation in landscape position:
Make an elongated hole in the wall (68mmx139mm). Use a holesaw (two holes next to each other with 68mm diameter, center distance 71mm).
For installation in portrait position:
Use a holesaw and make two holes among each other with 68mm diameter, center distance 71mm.
The backside of the flush-mount box can be used as a template. The depth should be approximately 75mm.
Important: This installation guide shows the installation process for a drywall. Here free is installed in landscape position.

Step 2

Cut a hole for the cable in the flush-mount box. Use the diagonal surfaces of the box for the cut. (See photo.) Cut the hole from the back side of the box. Make the hole correspond to the size needed for the cable.
If needed please prepare a second hole for the network LAN cable, please see
LAN/Ethernet extension module
Supplementary set for cable bound connection to home network. Please note that this set is a factory installed hardware.

Step 3

Insert the flush-mount box with the pre-installed installation disc into the opening in the wall. Pull
10-15 cm of the power cable through the opening.
For free in landscape position:
The integrated level will show you the 12 o’clock “UP” position. Adjust the flush mount box according to the level. (Final adjustments can be made at a later time.)
For free in portrait position:
The integrated level is in 3 o’clock position. Use an external level to align the box vertically.

Step 4

For drywall installation:
Fasten the flush-mount box to the wall.
For stone or solid wall installation:
Let the black installation disc mounted so that the flush mounted box is not deformed in any way.

! IMPORTANT: During installation, pay attention that the flush mount box is fastened parallel to the surface and is not shifted or offset in the wall.
! IMPORTANT: It is important that the flush mounted box is not deformed in any way. Do not use any foaming installation materials that may put pressure on the box and deform it.

Step 5

Remove the installation disc by loosening the screws.

Step 6

Now connect the connecting terminal with the current-carrying conductors (L, N) and the protective conductor.
Important: Make sure that the power supply cord is unplugged during the entire installation and cannot be turned on accidentally.
Note: Illustration is an example. Depending on the iPad and USB port, another power adapter can be supplied. Step 7

Re-insert the installation disc with the three screws
Important: Make sure that no cables are jammed between the flush mounting box and the installation disc. After completing installation, please make sure that the free is solidly secured to the wall.
Now you can install free. Please see the corresponding user manual.

Technical drawing

side view
from left to right: Flush mount box, wall, mounting plate, freeVIVeroo-
Mounting-Set-Inwall-Free-FIG 9

back view

Attention: Measurements show free for iPad mini 4. Measurements for other generation on previous page.
The size of free varies depending on the iPad generation. Mounting plate is always the same, it allows you to change iPad generation easily.VIVeroo-
Mounting-Set-Inwall-Free-FIG 10

MountingSet Furniture, free

VIVeroo-Mounting-Set-Inwall-Free-FIG
11

Safety information

Warning

Please read the assembly instructions included carefully. Please read this free user manual completely before using your free. Please follow the instructions and recommendations to ensure proper use and maximum enjoyment.

Safety information

free and all free mounting sets are intended for use in enclosed and dry living spaces.
The following conditions must be provided:

  • Ambient temperature: Usage: between 0° C (32° F) and 35° C (95° F), storage: between -10° C (14° F) and 50° C (122° F).
  • Relative humidity (during use): 20 % to 90 %, non-condensing.
  • No external environmental influences such as oil, chemicals, salt, extensive dust, etc.

Installation, service or repairs, if necessary, may only be performed by authorized persons.
The installer is responsible for selecting the proper mounting location and safe installation of free. This also applies to installation in movable parts, such as doors. The installer is responsible for performing and documenting all necessary safety tests.
All electrical installation work may only be conducted by authorized, trained electricians, always adhering to the general rules and regulations applying to electrical installation.
Should it become apparent that safe operation of free is not assured, then free must immediately be taken out of service and secured against potential misuse. If the free functions are limited, blocked or disabled, if an unusual odor is present, if noises such as scratching are audible or damage is visible, safe operation can no longer be guaranteed.

Technical Data

Product contents

  • Installation guide Furniture
  • USB Power Adapter
    (For USB-A: 100-240Vac, 50/60Hz, 12,5W, For USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W)

Compatability

Electrical operation of free is permitted only in connection with free MountingSet and power supply and cable included in the MountingSet. Operation of free without a MountingSet will lead to immediate loss of guarantee and warranty.

Measurements in millimeter

Measurements design cover free for …

  • … iPad mini 223 x 134
  • … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 267 x 164
  • … iPad 10.2 inch, Pro 10.5 inch 277 x 173
  • … iPad Pro 11 inch, Air (from 2020) 275 x 178
  • … iPad Pro 12.9 inch (from 2018) 307 x 215
  • Depth free 16
  • Size of opening (for furniture installation) Round hole, 50mm to put the connector through.
  • Installation depth (for furniture) 30

Weight in gram free for …

  • … iPad mini 876
  • … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 924
  • … iPad 10.2 inch, Pro 10.5 inch  952
  • … iPad Pro 11 inch, Air (from 2020) 993
  • … iPad Pro 12.9 inch (from 2018) 1.110

Electrical connections

  • Input voltage 200-240 Vac, 50/60 Hz via
  • Output voltage Europlug 5Vdc, 9Vdc or 12Vdc depending on iPad and USB connector

Removal from power supply

free may be removed from the power supply via the circuit breaker in the respective rooms.

Technical drawing

side view
from left to right: Wall, mounting plate, free.
Please note: Use holesaw ∅50mm to put the connector through.VIVeroo-
Mounting-Set-Inwall-Free-FIG 12

back view

Attention: Measurements show free for iPad mini 4. Measurements for other generations on the following page.
The size of free varies depending on the iPad generation. Mounting plate is always the same, it allows you to change iPad generation easily.VIVeroo-
Mounting-Set-Inwall-Free-FIG 13

MountingSet PoE / MontageSet PoE

Place the PoE adapter built into the bracket in the mounting box of the PoE mounting set. A PoE switch or an injector with the 802.3at standard is also required for the power supply.
The assembly set PoE is installed according to steps 1 to 4 on page 4 of these instructions.VIVeroo-Mounting-Set-Inwall-Free-FIG 14VIVeroo-Mounting-Set-Inwall-Free-FIG 15

free

  • viveroo GmbH
  • Wewelsburger Straße 4 33154 Salzkotten
  • Germany
  • www.viveroo.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals