VIVeroo MountingSet Inwall Free Installation Guide
- June 11, 2024
- viveroo
Table of Contents
VIVeroo MountingSet Inwall Free
Product Information
The viveroo free is a flush-mount box designed to hold various models of iPad, including iPad mini, iPad 9.7 inch, Air (before 2020), iPad Air 2, iPad Pro 9.7 inch, iPad 10.2 inch, Pro 10.5 inch, iPad Pro 11 inch, Air (from 2020), and iPad Pro 12.9 inch (from 2018). It comes with an installation guide Inwall, free flush-mount box with installation disc, incl. integrated level, a power supply unit (IN: 100-240 Vac, 50/60 Hz, OUT: 5,2 Vdc) or USB Power Adapter USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W, and an elongated hole of 68x139mm. The electrical operation of the viveroo free is only permitted in connection with the viveroo free MountingSet and power supply and cable included in the MountingSet.
Product Usage Instructions
Before installing the viveroo free, it is important to read the assembly
instructions included carefully. Also, read the user manual completely before
using your viveroo free. The viveroo free and all mounting sets are intended
for use in enclosed and dry living spaces without extensive dust, etc.
Installation, service or repairs, if necessary, may only be performed by
authorized persons.
The maximum altitude is 2.000m.
The installer is responsible for selecting the proper mounting location and safe installation of viveroo free. This also applies to installation in movable parts such as doors. The installer is responsible for performing and documenting all necessary safety tests. All electrical installation work may only be conducted by authorized, trained electricians, always adhering to the general rules and regulations applying to electrical installation.
Should it become apparent that safe operation of viveroo free is not assured, then viveroo free must immediately be taken out of service and secured against potential misuse. If the viveroo free functions are limited, blocked or disabled, if an unusual odor is present, if noises such as scratching are audible or damage is visible, safe operation can no longer be guaranteed.
To install the viveroo free, follow the below steps:
- Step 1: The viveroo free can be installed either in portrait or landscape position. It is your choice.
- Step 2: Follow the instructions and recommendations to ensure proper use and maximum enjoyment. The installer is responsible for performing and documenting all necessary safety tests.
Installation guide
MountingSet Inwall, free
Safety information
Important
Please read the assembly instructions included carefully before installing the MountingSet. Please also read the free user manual completely before using your free. Please follow the instructions and recommendations to ensure proper use and maximum enjoyment.
Safety information
free and all free mounting sets are intended for use in enclosed and dry
living spaces.
The following conditions must be provided:
- Operating temperature between 0° C (32° F) and 35° C (95° F).
- Relative humidity (during use): 20 % to 90 %, non-condensing.
- No external environmental influences such as oil, chemicals, salt, extensive dust, etc.
Installation, service or repairs, if necessary, may only be performed by
authorized persons.
The maximum altitude is 2.000m.
The installer is responsible for selecting the proper mounting location and
safe installation of free. This also applies to installation in movable parts,
such as doors. The installer is responsible for performing and documenting all
necessary safety tests.
All electrical installation work may only be conducted by authorized, trained
electricians, always adhering to the general rules and regulations applying to
electrical installation.
Should it become apparent that safe operation of free is not assured, then
free must immediately be taken out of service and secured against potential
misuse. If the free functions are limited, blocked or disabled, if an unusual
odor is present, if noises such as scratching are audible or damage is
visible, safe operation can no longer be guaranteed.
Technical Data
Product contents
- Installation guide Inwall
- free flush-mount box with installation disc, incl. integrated level
- Power supply unit (IN: 100-240 Vac, 50/60 Hz, OUT: 5,2 Vdc) or USB Power Adapter USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W
Compatability
Electrical operation of free is permitted only in connection with free MountingSet and power supply and cable included in the MountingSet. Operation of free without a MountingSet will lead to immediate loss of guarantee and warranty
Measurements in millimeter
Measurements design cover free for …
- … iPad mini 223 x 134
- … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 267 x 164
- … iPad 10.2 inch, Pro 10.5 inch 277 x 173
- … iPad Pro 11 inch, Air (from 2020) 275 x 178
- … iPad Pro 12.9 inch (from 2018) 332 x 214
Depth free 16
Size of opening
(for flush-mounted box) elongated hole 68×139
Installation depth
(for flush-mounted box) 75
Weight in gram
free for …
- … iPad mini 876
- … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 924
- … iPad 10.2 inch, Pro 10.5 inch 952
- … iPad Pro 11 inch, Air (from 2020) 993
- … iPad Pro 12.9 inch (from 2018) 1.110
Electrical connections
- Power supply 100-240 Vac 50-60 Hz
- Power consumption 12,5Watt – 18Watt, depending on iPad and power supply
Removal from power supply
free may be removed from the power supply via the circuit breaker in the respective rooms.
Technical changes and mistakes are excepted.
Apple, iPad and Lightning are registered trademarks of Apple Inc.
Installation flush-mount box
Step 1
free can be installed either in portrait or landscape position, it is your
choice.
For installation in landscape position:
Make an elongated hole in the wall (68mmx139mm). Use a holesaw (two holes next
to each other with 68mm diameter, center distance 71mm).
For installation in portrait position:
Use a holesaw and make two holes among each other with 68mm diameter, center
distance 71mm.
The backside of the flush-mount box can be used as a template. The depth
should be approximately 75mm.
Important: This installation guide shows the installation process for a
drywall. Here free is installed in landscape position.
Step 2
Cut a hole for the cable in the flush-mount box. Use the diagonal surfaces of
the box for the cut. (See photo.) Cut the hole from the back side of the box.
Make the hole correspond to the size needed for the cable.
If needed please prepare a second hole for the network LAN cable, please see
LAN/Ethernet extension module
Supplementary set for cable bound connection to home network. Please note that
this set is a factory installed hardware.
Step 3
Insert the flush-mount box with the pre-installed installation disc into the
opening in the wall. Pull
10-15 cm of the power cable through the opening.
For free in landscape position:
The integrated level will show you the 12 o’clock “UP” position. Adjust the
flush mount box according to the level. (Final adjustments can be made at a
later time.)
For free in portrait position:
The integrated level is in 3 o’clock position. Use an external level to align
the box vertically.
Step 4
For drywall installation:
Fasten the flush-mount box to the wall.
For stone or solid wall installation:
Let the black installation disc mounted so that the flush mounted box is not
deformed in any way.
! IMPORTANT: During installation, pay attention that the flush mount box
is fastened parallel to the surface and is not shifted or offset in the wall.
! IMPORTANT: It is important that the flush mounted box is not deformed
in any way. Do not use any foaming installation materials that may put
pressure on the box and deform it.
Step 5
Remove the installation disc by loosening the screws.
Step 6
Now connect the connecting terminal with the current-carrying conductors (L,
N) and the protective conductor.
Important: Make sure that the power supply cord is unplugged during the
entire installation and cannot be turned on accidentally.
Note: Illustration is an example. Depending on the iPad and USB port,
another power adapter can be supplied. Step 7
Re-insert the installation disc with the three screws
Important: Make sure that no cables are jammed between the flush mounting
box and the installation disc. After completing installation, please make sure
that the free is solidly secured to the wall.
Now you can install free. Please see the corresponding user manual.
Technical drawing
side view
from left to right: Flush mount box, wall, mounting plate, free
back view
Attention: Measurements show free for iPad mini 4. Measurements for other
generation on previous page.
The size of free varies depending on the iPad generation. Mounting plate is
always the same, it allows you to change iPad generation easily.
MountingSet Furniture, free
Safety information
Warning
Please read the assembly instructions included carefully. Please read this free user manual completely before using your free. Please follow the instructions and recommendations to ensure proper use and maximum enjoyment.
Safety information
free and all free mounting sets are intended for use in enclosed and dry
living spaces.
The following conditions must be provided:
- Ambient temperature: Usage: between 0° C (32° F) and 35° C (95° F), storage: between -10° C (14° F) and 50° C (122° F).
- Relative humidity (during use): 20 % to 90 %, non-condensing.
- No external environmental influences such as oil, chemicals, salt, extensive dust, etc.
Installation, service or repairs, if necessary, may only be performed by
authorized persons.
The installer is responsible for selecting the proper mounting location and
safe installation of free. This also applies to installation in movable parts,
such as doors. The installer is responsible for performing and documenting all
necessary safety tests.
All electrical installation work may only be conducted by authorized, trained
electricians, always adhering to the general rules and regulations applying to
electrical installation.
Should it become apparent that safe operation of free is not assured, then
free must immediately be taken out of service and secured against potential
misuse. If the free functions are limited, blocked or disabled, if an unusual
odor is present, if noises such as scratching are audible or damage is
visible, safe operation can no longer be guaranteed.
Technical Data
Product contents
- Installation guide Furniture
- USB Power Adapter
(For USB-A: 100-240Vac, 50/60Hz, 12,5W, For USB-C: 100-240Vac, 50/60Hz, PD 3.0, up to 18W)
Compatability
Electrical operation of free is permitted only in connection with free MountingSet and power supply and cable included in the MountingSet. Operation of free without a MountingSet will lead to immediate loss of guarantee and warranty.
Measurements in millimeter
Measurements design cover free for …
- … iPad mini 223 x 134
- … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 267 x 164
- … iPad 10.2 inch, Pro 10.5 inch 277 x 173
- … iPad Pro 11 inch, Air (from 2020) 275 x 178
- … iPad Pro 12.9 inch (from 2018) 307 x 215
- Depth free 16
- Size of opening (for furniture installation) Round hole, 50mm to put the connector through.
- Installation depth (for furniture) 30
Weight in gram free for …
- … iPad mini 876
- … iPad 9.7 inch, Air (before 2020) iPad Air 2, iPad Pro 9.7 inch 924
- … iPad 10.2 inch, Pro 10.5 inch 952
- … iPad Pro 11 inch, Air (from 2020) 993
- … iPad Pro 12.9 inch (from 2018) 1.110
Electrical connections
- Input voltage 200-240 Vac, 50/60 Hz via
- Output voltage Europlug 5Vdc, 9Vdc or 12Vdc depending on iPad and USB connector
Removal from power supply
free may be removed from the power supply via the circuit breaker in the respective rooms.
Technical drawing
side view
from left to right: Wall, mounting plate, free.
Please note: Use holesaw ∅50mm to put the connector through.
back view
Attention: Measurements show free for iPad mini 4. Measurements for other
generations on the following page.
The size of free varies depending on the iPad generation. Mounting plate is
always the same, it allows you to change iPad generation easily.
MountingSet PoE / MontageSet PoE
Place the PoE adapter built into the bracket in the mounting box of the PoE
mounting set. A PoE switch or an injector with the 802.3at standard is also
required for the power supply.
The assembly set PoE is installed according to steps 1 to 4 on page 4 of these
instructions.
free
- viveroo GmbH
- Wewelsburger Straße 4 33154 Salzkotten
- Germany
- www.viveroo.com