Thank you for purchasing a Concept product. We hope you will be satisfied with our product throughout its service life. Please read carefully the whole instruction manual before you use the appliance for the first time; after reading, store and keep the instruction manual in a safe and handy place. Make sure that all other persons using the appliance know the contents of the instruction manual.
5&$)/*$”- 1″3″.&5&34
Voltage| 230 V ~ 50 Hz
Power input| 210 W
Version| Chimney
“44&.#-:| Wall
Width| 595 mm
Depth| 480 mm
Height| 640 – 970 mm
Output piping diameter| 150 mm
/VNCFS PG GBOT| 1
/VNCFS PG GBO QPXFS MFWFMT| 3
Capacity| max 550 m3/h
/VNCFS PG GBU mMUFST| 2
Mode| Airing or re-circulation
-JHIUJOH| 2x 28W Halogen
Weight| 10 Kg
Noise level, airing/re-circulation| < 68 dB (A)
The manufacturer reserves the right to perform technical modifications, and the possible occurrence of print errors and differences in the figures provided without previous notice.
IMPORTANT NOTICES
On appliance delivery
- Check the package and unit immediately after delivery for any damage that may have occurred during shipping.
- If the unit is damaged, do not operate it. Contact the supplier as soon as possible.
- Remove all packing and marketing material from the appliance before you use it for the first time.
- Dispose of the packaging material properly
During installation
- The unit is designed to be assembled under the upper cupboard of a kitchen set.
- Follow the instructions for the appliance connection and installation.
- The unit has to be disconnected from the power outlet during installation.
- Prior to the first operation of the appliance make sure that your local connection is earthed and compliant with all applicable safety regulations.
- Make sure the mains voltage and current protection correspond to the values on the rating plate. Use earthed wall outlets only.
- After installation of the appliance, the plug or circuit breaker must be freely accessible.
- Only a properly authorised technician must install and connect your appliance.
- The appliance incorrectly connected or operated after an incompetent installation may cause serious injury or death to persons.
- The manufacturer takes no responsibility for any damage incurred due to improper installation or use.
In regular operation
- Do not use the appliance differently than described in this manual.
- Use the appliance only in a household, solely for the purpose of absorbing vapor created during cooking, or re-circulation and absorption of odours created during cooking.
- Install the appliance at least 650 mm above the electric stove (or hotplate), and at least 750 mm above the gas stove (or gas hotplate).
- Do not touch the appliance with moist or wet hands.
- In case of any failure, and prior to maintenance and cleaning, turn off the appliance and disconnect the plug from the mains outlet, or switch off the circuit breaker.
- Never hold the supply cable when disconnecting the appliance from the electric voltage socket by pulling; hold the plug instead.
- Regularly check the appliance and the supply cable for any damage. Never turn the appliance on when damaged.
- Do not immerse the power cord or plug in water or any other liquid.
- Make sure that all controls are in the OFF position when the appliance is not in use.
- Do not handle an open flame under the unit (e.g. flaming)! If you remove a cooking vessel from the gas stove, turn down the flame to the minimum, or turn it off!
- Make sure the diameter of the burner of the gas stove or gas hotplate corresponds to the cooking kitchenware used. When using smaller than recommended vessels, the flames could touch the sides, and plastic handles could be scorched risk of fire!
- When you deep-fry or fry food, keep it under continuous supervision. When oil is overheated, there is a risk of fire!
- Keep the intervals for replacement and cleaning of the filters (every 2 months at minimum). If these instructions are not followed, there is a risk of fire due to fat sediments in the filters!
- Taking off the exhausted air must observe all the applicable standards and regulations.
- In the airing mode, the exhaust duct diameter should be approximately the same as the vapor absorber’s output piping.
- The air must not be exhausted through a chimney used for combustion gases, or in a shaft used for airing rooms where combustion chambers are installed.
- During the operation in airing mode, a sufficient opening for inlet air must be made; its size should be] approximately the same as or bigger than the hole for exhausting air.
- During simultaneous operation of the appliance in the airing mode and the stove, the under-pressure in the room must not exceed 4 Pa (0.04 bar).
- Do not use any other accessories except those recommended by the manufacturer.
Children in the household
- Do not allow children or irresponsible people to handle the appliance. Use the appliance out of the reach of these persons.
- Handicapped persons, persons with impaired sensation, or mental capabilities, or persons not familiar with the appliance operation are only allowed to use it when supervised by responsible knowledgeable persons.
- Take extra care when using the appliance near children.
- Do not allow the appliance to be used as a toy.
PRODUCT DESCRIPTION
- Upper chimney cover
- Body of the unit
- Control panel
DESCRIPTION OF THE CONTROL PANEL
- Fan power level switch
- Lighting switch
OPERATING INSTRUCTIONS
Prior to first use
- Prior to operating a new appliance for the first time, wipe it with a wet and then a dry cloth.
- Prior to switching the appliance on for the first time, check whether the textile fat retention filter is fixed properly.
Airing mode
In this mode, the exhausted vapors are ventilated through the output pipe into the airing shaft and out of the room. If the carbon filter is installed in the appliance, remove it (Refer to the Cleaning and Maintenance chapter).
- Using the fan power level adjustment switch (1) select the fan power required (1-3).
- After you stop using it, turn off the appliance by setting the fan power level adjustment switch (1) to the,0″ position (Turned off).
Re-circulation mode
If you have no possibility to exhaust the air out of the room, the re- circulation mode can be selected. In this mode, the vapors exhausted are filtered through the fat retention filter and the carbon filter. The active carbon present in this filter absorbs odors, and the cleaned air flows back into the room. For this mode, you have to buy and mount a corresponding carbon filter (Refer to the Cleaning and Maintenance chapter), blind the output opening, and switch the air output clack (Refer to the Appliance Installation chapter).
- Using the fan power level adjustment switch (1) select the fan power required (1 – 3).
- After you stop using it, turn off the appliance by setting the fan power level adjustment switch (1) to the,0″ position (Turned off).
Lighting on/off switching
- Press the switch (2) to turn the light on or off.
CLEANING AND MAINTENANCE
- Before any maintenance and cleaning, disconnect the power cord from the mains or switch off the circuit breaker of the appliance mains outlet.
- Do not immerse the supply cable, the plug, or the appliance itself in water or any other liquid. Set all controls in the OFF position.
- Clean the outer surface of the appliance with a wet cloth, or use a neutral cleaning agent.
- Do not use steel wool, coarse sponges, abrasive cleaners, solvents or aggressive cleaning agents.
- Do not use an autoclave to clean the appliance
CLEANING AND REPLACING THE FILTER
Metallic fat filters
Under normal use the metallic fat filters should be cleaned every 2 months. In
case of more frequent frying or deep frying make the interval shorter.
Do not use the unit without properly mounted metallic fat filters!
- Remove the metallic filters (Fig. 1). In case there are carbon filters mounted, remove them.
- Put the metallic filters in warm water with a detergent. Clean them with a soft brush, rinse with clean water and let dry.
- Remount completely dry filters following the reverse steps.
- Carbon filter (must be separately bought) his filter is used only in the re-circulation mode.
- The iter contains active carbon that absorbs the ventilated odors. After a while, the active carbon is saturated and loses its absorption ability. The filter can’t be washed or otherwise cleaned.
- Under regular use, the carbon filter should be replaced every 2 months. In case of more frequent frying or deep frying, shorten the replacement interval.
APPLIANCE INSTALLATION
- Only an authorized professional can install the appliance power connection!
- Only the customer, not the manufacturer, is responsible for the appliance installation.
- Defects caused by the incorrect installation are not covered by the warranty.
- Remove all packing and marketing material from the appliance before you use it for the first time.
- We recommend that you let a specialized company perform the installation.
- The manufacturer bears no responsibility for damage caused to people, animals or objects as a result of incorrect installation.
Follow the installation instructions below:
- Remove the fat retention (or also the carbon) filter.
- Put the appliance on the lower edge of the upper cupboard of the kitchen set.
- Check the minimum required height according to Fig. 3 (650 mm for electric, and 750 mm for gas hotplates).
- You will see the fixed hanging holes through the lower opening in the appliance.
- Mark the positions of these holes on the wall and the cupboard bottom side.
- Mark the position and diameter of the hole for the output piping. Drill the fixing holes in the wall, possibly also for the output piping.
- Fix the appliance to the wall using the wall plugs and screws (Fig. 4).
- 8. Fix the appliance to the cupboard bottom side using the screws.
- Mount the clack valve on the fan output hole selected, and connect the fan output hole to the hole in the wall using a flexible pipe.
- Note: Flexible piping is not part of delivery.
- In the recirculation mode, the output air will be blown through the holes in the appliance’s upper front panel. The following adjustment must be made for the re-circulation mode:
- Place the fat retention (or also the carbon) filter.
- Plug the supply cable into the wall outlet.
Disassembly: Prior to disassembly, disconnect the power cable from the wall outlet; follow the reverse steps to remove the single parts of the appliance.
SERVICING
Bulb replacement
Before replacement, let the bulb cool down. Burn danger!
For the replacement, proceed as follows:
- Pull the power cord out of the mains outlet or switch off the circuit breaker of the appliance’s mains outlet.
- Demount the protection glass and replace the bulb for a new one of the same type (Max. 40 W)!
- Remount the covering protection glass.
Note: You can also demount the bulb after demounting the appliance bottom metal cover.
ENVIRONMENTAL PROTECTION
- Packaging materials and obsolete appliances should be recycled.
- The transport box may be disposed of as sorted waste.
- Polyethylene bags shall be handed over for recycling.
Appliance recycling at the end of its service life:
- A symbol on the product or its packaging indicates that this product should not go into household waste.
- It must be taken to the collection point of an electric and electronic equipment recycling facility.
- By making sure this product is disposed of properly, you will help prevent the negative effects on the environment and human health that would otherwise result from inappropriate disposal of this product
- You can learn more about recycling this product from your local authorities, a household waste disposal service, or in the shop where you bought this product.
Elko Valenta Polska Sp. Z. o. o.
- AD: strowskiego 30, 53-238 Wroclaw
- Tel: +48 71 339 04 44, Fax: 71 339 04 14
- www.my-concept.pl
References
- Concept – chytře vymyšleno pro život
- Domena Concept.pl jest na sprzedaż - SklepDomeny.pl
- Luxury Architecture, Concept Architects, Bratislava
- Online software pre autoservis | servis.sk
- Tech.sk | Všetko o informačných technológiáchTech.sk | Magazín o internete a technológiách
- Concept
- Concept – chytře vymyšleno pro život
- Concept innowacje w Twoim życiu!
- www.my-concept.sk | vymyslené pre život
- Verners
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>