viveroo REV20170624 MountingSet Inwall Loop Installation Guide
- June 9, 2024
- viveroo
Table of Contents
Installation guide
MountingSet Inwall, loop
Safety information
!ATTENTION
Please read the assembly instructions included carefully before installing the
MountingSet. Please also read the loop user manual completely before using
your loop. Please follow the instructions and recommendations to ensure proper
use and maximum enjoyment.
Safety information
loop and all loop mounting sets are intended for use in enclosed and dry
living spaces.
The following conditions must be provided:
– Operating temperature between 0° C (32° F) and 35° C (95° F).
– Relative humidity (during use): 20 % to 90 %, non-condensing.
– No external environmental influences such as oil, chemicals, salt, extensive
dust, etc.
The maximum altitude is 2.000m.
Installation, service or repairs, if necessary, may only be performed by
authorized persons.
The installer is responsible for selecting the proper mounting location and
safe installation of loop. This also applies to installation in movable parts,
such as doors. The installer is responsible for performing and documenting all
necessary safety tests.
All electrical installation work may only be conducted by authorized, trained
electricians, always adhering to the general rules and regulations applying to
electrical installation. Wire end sleeves and ferrules must be used for
flexible cables. Should it become apparent that safe operation of loop is not
assured, then loop must immediately be taken out of service and secured
against potential misuse. If the loop functions are limited, blocked or
disabled, if an unusual odor is present, if noises such as scratching are
audible or damage is visible, safe operation can no longer be guaranteed.
Technical Data
Product contents
– Installation guide Inwall
– loop flush mounting box with installation disc (rotating disc), incl.
integrated level
– Power supply (IN 100-240 Vac, 50-60 Hz, OUT 12 Vdc) with pre-installed loop
power cable (including usage guidelines and installation guide)
– Fastening screw packet (for attaching loop) with various length screws (see
„Installation“ section)
Compatability
Electrical operation of loop is permitted only in connection with loop
Mounting Set and power supply and cable included in the Mounting Set.
Operation of loop without a Mounting Set will lead to immediate loss of
guarantee and warranty.
Measurements in mm | Diameter design cover | 385 |
---|---|---|
Depth loop | 39 | |
Diameter opening (for flush-mounted box) | 363 – 365 | |
Installation depth loop (for flush mounting) | 66 | |
4,8 | ||
Weight in kg | loop | 4,8 |
Electrical connections | (Power supply is provided in MountingSet) | 100-240 Vac |
50 – 60 Hz
Power consumption| 18 Watt
Removal from power supply
loop may be removed from the power supply via the circuit breaker in the
respective rooms.
Circuit Breaker
16A (EU) , 20A (USA/Canada)
Overvoltage category
OVC II
Wire crosssection
The permitted conductive cross-section is between 0.75mm² and 2.5mm².
*) Technical changes and mistakes are excepted.
iPad is a registered trademark of Apple Inc.
Installation Flush Mount Box
Step 1
Make an round opening in the wall. The diameter should be between 363 and 365
mm, the depth should be approximately 70 mm.
Step 2
Insert the flush mount box with the pre-installed rotating disc into the
opening in the wall. Pull 20-25 cm of the power cable through the opening. The
integrated level will show you the “UP” position. (The 12:00 o’clock position)
Adjust the flush mount box according to the level. (Final adjustments can be
made at a later time.)
! IMPORTANT: During installation, pay attention that the flush mount box
is fastened parallel to the surface and is not shifted or offset in the wall.
! IMPORTANT: It is important that the flush mounted box is not deformed in
any way. Do not use any foaming installation materials that may put pressure
on the box and deform it.
! WARNING: Make sure that the power supply cord is unplugged during the
entire installation and cannot be turned on accidentally.
Step 3
Remove the three screws in the rotating disc. Plug the power cord into the
3-pin device connecting terminal (N, L, PE).
Step 4
Re-insert the rotating disc. Make sure that the loop connecting cable is
inserted from the front through the opening in the rotating disc.
Attach the rotating disc with the three screws and make fine adjustments using
the integrated level.
! ATTENTION: Make sure that no cables are jammed between the flush
mounting box and the rotating disc.
Step 5
Now the loop can be connected and inserted. Please refer to the loop user
manual for instructions on proper installation of the loop.
! IMPORTANT for
cavity wall installation: Please use the shorter screws when fastening the
rotating disc to the flush mounted box.
! IMPORTANT for brick-wall installation: Please use the shorter screws
when fastening the rotating disc to the flush mounted box. Should these be too
short, please use the
longer screws.
! ATTENTION: After completing installation, please make sure that the loop
is solidly secured to the wall as well as secure electrical
connection/function.
Technical Details
loop
Measurements for installation in solid, concrete and hollow walls (with
wall case), in mm
Installation
Use the three inner holes to screw the mounting plate to the wall!
Short or long screw
Short or long screw:
The shorter screws are good for cavity walls. If the flush mounted box is
installed under the plaster on thebrick wall, use the longer screws. Always
start with the shorter screws!
Cutting measurements for solid, concrete and hollow walls, (for the wall case), in mm
MountingSet Inwall zero loop
Incl. MountingSet Inwall + flush mount frame with reinforcing grid REV20180809
Safety informaion
!! Important:
Before installing this MountingSystem please read the following information.
Follow the instructions and recommendations described.
General conditions:
The MountingSet Inwall zero is an extension of MountingSet Inwall.
Accordingly, it is assumed that both products are built in combination.
The following embedding materials are approved for the attachment and
incorporation of MountginSet Inwall zero: mineral plaster, polymer modified
adhesive and reinforcement cement.
The MountingSet is designed for installation in dry and closed living spaces.
The following environmental conditions are ensured:
Ambient temperature 0 °C to 35 °C
No environmental influences, such as oil, chemicals, salt and comparable
No direct sunlight
The MountingSet must be processed and installed only by authorized personnel.
This includes the proper installation of electrical connections. The
responsibility for proper installation and safe installation of the
MountingSet is only with the processor. Basically, the user has to make and
certify all safety checks.
Delivery contents
– Installation guide, flush-plastered MountingSet Inwall zero
– Flush mount frame with reinforcing grid
Installation in hollow walls (plasterboard)
Bring Circular hole with a diameter of 365mm in the gypsum board. Provide a
mounting depth of 70 mm in the cavity wall. Place the power cable.
Clean the surface of the gypsum board thoroughly and fix the flush mount frame
on the gypsum fibreboard -concentric with the hole.
!! Important: The gypsum fibreboard must provide a very smooth, surface
adhesion for the flush mount frame, stress- and distortion-free!
Incorporate the flush mount frame with approved embedding material (see
above). To do this, prepare the surface according to VOB, Section C, DIN
18363, DIN 18350 or BFS notices. Then apply the embedding material evenly to
the gypsum fibreboard according to the manufacturer’s instructions. Embed the
reinforcement fabric of the frame in the wet coating without any creases.
After that apply embedding material again evenly, so that the grid is no
longer visible.
Depending on the design ideas the flush mount frame can be plastered up to the
upper edge.
After the embedding material has perfectly dried out, please clean the inner
surfaces of the frame and insert the wall case / flush mount box. Please
follow the installation guide for the MountingSet Inwall.
!! Attention: Install the flush box so deep that it rests firmly on the
inner ring of the frame.
!! Attention: Screw the wall case / flush mount box so tight that it
stabilizes the frame.
Installation in brick walls and concrete walls (shell)
Bring Circular hole with a diameter of 365 mm in wall. Provide a mounting
depth of 70 mm in the cavity wall. Place the power cable.
Apply subsoil / substrate plaster to the wall and fix the flush mount frame –
concentric with the hole for the wall case / flush mount box.
!! Important: The subsoil / substrate plaster must provide a very smooth,
surface adhesion for the flush mount frame, stress- and distortion-free!
Incorporate the flush mount frame with approved embedding material (see
above). To do this, prepare the surface according to VOB, Section C, DIN
18363, DIN 18350 or BFS notices. Then apply the embedding material evenly to
the gypsum fibreboard according to the manufacturer’s instructions. Embed the
reinforcement fabric of the frame in the wet coating without any creases.
After that apply embedding material again evenly, so that the grid is no
longer visible. Depending on the design ideas the flush mount frame can be
plastered up to the upper edge.
After the embedding material has perfectly dried out, please clean the inner
surfaces of the frame. Insert the wall case / flush mount box and fix it with
fastening material such as plaster or mortar or cement – Please follow the
installation guide for the MountingSet Inwall.
!! Attention: Install the flush box so deep that it rests firmly on the inner
ring of the frame.
!! Attention: Screw the wall case / flush mount box so tight that it
stabilizes the frame.
Images for illustration
Information:
Follow sequence: 1. Flush mount frame , 2. flush mount box , 3. loop
Install the flush box so deep that it rests firmly on the inner ring of the frame.
Information
When installed, the loop forms a flat surface with the wall. There is a 1mm
wide shadow gap (red) around the loop.
Sectional drawing
Installation guide
MountingSet Furniture for loop and square
viveroo GmbH
Wewelsburger Straße 4
33154 Salzkotten
Germany
www.viveroo.de
Safety information
!ATTENTION
Please read the assembly instructions included carefully before installing the
MountingSet. Please also read the loop user manual completely before using
your loop. Please follow the instructions and recommendations to ensure proper
use and maximum enjoyment.
Safety information
loop and all loop mounting sets are intended for use in enclosed and dry
living spaces.
The following conditions must be provided:
– Operating temperature between 0° C (32° F) and 35° C (95° F).
– Relative humidity (during use): 20 % to 90 %, non-condensing.
– No external environmental influences such as oil, chemicals, salt, extensive
dust, etc.
The maximum altitude is 2.000m.
Installation, service or repairs, if necessary, may only be performed by
authorized persons.
The installer is responsible for selecting the proper mounting location and
safe installation of loop. This also applies to installation in movable parts,
such as doors. The installer is responsible for performing and documenting all
necessary safety tests.
All electrical installation work may only be conducted by authorized, trained
electricians, always adhering to the general rules and regulations applying to
electrical installation. Wire end sleeves and ferrules must be used for
flexible cables. Should it become apparent that safe operation of loop is not
assured, then loop must immediately be taken out of service and secured
against potential misuse. If the loop functions are limited, blocked or
disabled, if an unusual odor is present, if noises such as scratching are
audible or damage is visible, safe operation can no longer be guaranteed.
Technical data
Product contents
– Installation guide MountingSet Furniture
– Power supply (IN 200-240 Vac, 50 Hz, OUT 12 Vdc) especially for furniture
mounting, incl. seperate installation guide
– 1m cable (to connect power supply to loop or square)
– 1m power cord (to connect power supply to wall socket)
– screw set: 4 pieces 3x25mm and 4 pieces 3,5x25mm
Compatability
Electrical operation of loop is permitted only in connection with loop
Mounting Set and power supply and cable included in the Mounting Set.
Operation of loop without a Mounting Set will lead to immediate loss of
guarantee and warranty.
Electrical connections| Netzspannung| 200-240 Vac
50 Hz
---|---|---
Power consumption.
!! Attention: Please also the manual provided twith the power supply.| 15 Watt
Removal from power supply
loop may be removed from the power supply via the circuit breaker in the
respective rooms.
*) Technical changes and mistakes are exceptediPad is a registered trademark of Apple Inc.
Technical Details
loop
Measurements for installation in furniture, cabinets, wooden materials, in
mm
Cutting measurements for wood, in mm
a = 9mm for flush-mounted installation
a = 0mm for overlying mounting (not flush)
Do it right!
-
!! Important for loop for square Use included screws only!
Why? The screw head must be extremely flat.
Special screws of assorted diameters are included. The choice is yours.
For square use the 4 inner screw holes.
For loop use the 3 outer screw holes.
Installation guide for loop. Inwall, Zero and furniture -
!! Important for loop
viveroo GmbH
Wewelsburger Straße 4
33154 Salzkotten
Germany
www.viveroo.com
References
- iPad Halterung - iPad Wandhalterung und iPad Ständer | viveroo
- iPad Halterung - iPad Wandhalterung und iPad Ständer | viveroo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>