Features
  • 1-channel
  • Output Ex ia
  • Installation in suitable enclosures in Zone 1
  • Module can be exchanged under voltage (hot swap)
  • Analog output module for 0/4 mA … 20 mA
  • HART communication via field bus or service bus
  • Simulation mode for service operations (forcing)
  • Line fault detection (LFD)
  • Permanently self-monitoring

Icons

Function

The device drives positioners, proportional valves, I/P converters, or local indicators.
Open and short-circuit line faults are detected.
The output is galvanically isolated from the bus and the power supply.

Connection

Connection

Technical Data

Slots

  • Occupied slots 1

Supply

  • Connection: backplane bus
  • Rated voltage: Ur 12 V DC , only in connection with the power supplies FB92**
  • Power dissipation: 0.8 W
  • Power consumption: 0.95 W

Internal bus

  • Connection: backplane bus
  • Interface: manufacturer-specific bus to standard com unit

Analog output

  • Number of channels: 1

Suitable field devices

  • Field device: Proportional Valve
  • Field device [2]: I/P converters
  • Field device [3]: on-site display
  • Connection: channel I: 2/3+, 4/5-
  • Current: 0 … 25 mA short-circuit protected
  • Line fault detection: can be switched on/off for each channel via configuration tool , configurable via configuration tool
    • Short-circuit: No
    • Open-circuit: deviation of preset output value > 0.5 mA
  • Load: 750 Ω max.
  • HART communication: yes
  • HART secondary variable: MODBUS: yes; all other bus systems: no
  • Watchdog: within 0.5 s the device goes in safe state, e.g. after loss of communication

Transfer characteristics

Deviation

  • After calibration: 0.1 % of the signal range at 20 °C (68 °F)
  • Influence of ambient temperature: 0.1 %/10 K of the signal range
  • Refresh time: 100 ms

Indicators/settings

  • LED indication:
    Power LED (P) green:
    supply
    Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit
    Status LED (1) red: line fault (lead breakage or short circuit)

  • Coding: optional mechanical coding via front socket

Directive conformity

  • Electromagnetic compatibility
  • Directive 2014/30/EU: EN 61326-1:2013

Conformity

  • Electromagnetic compatibility: NE 21:2007
  • Degree of protection: IEC 60529:2000
  • Environmental test: EN 60068-2-14:2009
  • Shock resistance: EN 60068-2-27:2009
  • Vibration resistance: EN 60068-2-6:2008
  • Damaging gas: EN 60068-2-42:2003
  • Relative humidity: EN 60068-2-78:2001

Ambient conditions

  • Ambient temperature: -20 … 60 °C (-4 … 140 °F)

  • Storage temperature: -25 … 85 °C (-13 … 185 °F)

  • Relative humidity: 95 % non-condensing

  • Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18

  • Vibration resistance:
    frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance

  • Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

  • Degree of protection: IP20 (module) , a separate housing is required acc. to the system description
  • Connection: removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 … 1.5 mm2 ) or screw terminals (0.08 … 1.5 mm2)
  • Mass: approx. 350 g
  • Dimensions: 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch)

Data for application in connection with hazardous areas

  • EU-type examination certificate: BVS 12 ATEX E 015 X
  • Marking
    1 II 2(1) G Ex d [ia Ga] IIC T4 Gb
    1 II (1) D [Ex ia Da] IIIC

Output

  • Voltage: Uo 27 V
  • Current: Io 87 mA
  • Power: Po 575 mW (linear characteristic)

Galvanic isolation

  • Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11:2007 , voltage peak value 375 V

Directive conformity

  • Directive 2014/34/EU
    EN IEC 60079-0:2018+AC:2020
    EN 60079-1:2014
    EN 60079-11:2012

International approvals

  • ATEX approval: BVS 12 ATEX E 015 X

General information

  • System information
    The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.

  • Supplementary information
    EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Assembly

Assembly Instructions

Refer to “General Notes Relating to Pepperl+Fuchs Product Information”

Pepperl+Fuchs Group
www.pepperl-fuchs.com

USA: +1 330 486 0002
pa-info@us.pepperl-fuchs.com

Germany: +49 621 776 2222
pa-info@de.pepperl-fuchs.com

Singapore: +65 6779 9091
pa-info@sg.pepperl-fuchs.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pepperl Fuchs User Manuals

Related Manuals