ENERGETIC E5SLB Series LED Strip Light Instruction Manual

June 9, 2024
energetic

LED Strip Light
Installation Instructions
Model # E5SLB seriesENERGETIC E5SLB Series LED Strip Light
-

ATTACH YOUR RECEIPT HERE

Item Number
Purchase Date

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-492-6566.

PACKAGE CONTENTS

ENERGETIC E5SLB Series LED Strip Light - PACKAGE
CONTENTS

Part Item Name Qty.
A LED cover assembly 1
B Housing base 1

HARDWARE CONTENTS

ENERGETIC E5SLB Series LED Strip Light - HARDWARE
CONTENTS.

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product. Failure to do so could lead to electric shock, fire or other injuries that could be hazardous or even fatal.

  • Be sure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • This product must be installed in accordance with local, state and national electrical codes.
  • Installation work shall be completed by a licensed installer that is familiar with the construction and operations of the product.

CAUTION:

  • This product is dimmable with 0-10v dimming systems only.
  • Units configured with battery backup systems contain a rechargeable LiFePO4 type battery and must be recycled or disposed of properly according to local jurisdictions.

NOTICE

  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTICE:

  • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
    – Reorient or relocate the receiving antenna.
    – Increase the separation between the equipment and the receiver.
    – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    – Consult the dealer or an experienced radio/TV technician for help.

  • This Class B digital apparatus complies with Canadian ICES-003.

INSTALLATION INSTRUCTIONS

The below steps outline the surface mounting method, where fixture body is fastened directly to the mounting surface. Alternate mounting methods are outlined in the steps on

  1. Gently press housing base (B) near one end of the fixture while pulling the metal part of the LED cover assembly (A) so that housing separates at the seam as shown.ENERGETIC E5SLB Series LED Strip Light - LED cover

  2. There is no need to disconnect the two halves of the fixture body. Support cables will support the weight of the LED cover assembly (A) during positioning of the hosuing base (B) up again the mounting surface.ENERGETIC E5SLB Series LED Strip Light - during positioning

  3. Align knockout hole with the supply wire location on junction box, adjust the fixture to the desired mounting angle and mark the mounting holes through the keyhole slots at both ends of the strip fixture housing base (B).

  4. DRYWALL MOUNTING: If the mounting holes go through drywall without a stud, drill two small pilot holes using a 3/16-in. drill bit (not included), and install drywall anchors (AA) into the holes with a hammer (not included).
    CEILING STUD MOUNTING: If the mounting holes go through ceiling studs, drill four small pilot holes using a 5/32-in. drill bit (not included) for the wood screws (BB).
    NOTE: Install Wood screws (BB) but leave about 1/2-in. of space between the screw head and mounting surface.

  5. Feed the supply wires from the mounting surface through the knockout hole on the housing base (B).
    Guide the heads of the two wood screws into the keyhole slots and slide the housing base (B) in the direction such that the wood screw heads rest over the narrow part of the keyhole slot. Ensure that the fixture is supported and tighten the two wood screws (DD) until the fixture is secured to the mounting surface.

  6. a. If the fixture is equipped with an emergency battery backup system, proceed to step 6b, for fixtures without the battery backup system, proceed with 6a below: Connect the fixture wires to the supply wires — black to black, white to white, and green to copper/bare. WARNING: If there is no ground supply wire, stop installation and consult a qualified electrician.
    NOTE: If 0-10v dimming system is available, connect the purple and gray wires to the corresponding purple and gray wires in the building dimming system.
    Once wire connections are made, secure each with a wire nut (CC). 6b. If the fixture is configured with an emergency battery back-up system:
    Connect neutral supply line to white, and ground supply line to green. Note that there are two line (hot) leads, labelled as “switched” and “unswitched”, ensure that the “unswitched” lead is connected to constant building power (this lead senses the presence of a power outage); the “switched” lead is connected to the hot lead of a wall switch or control relay to turn fixture off without triggering the EM battery.
    NOTE: Connect the two loose connector leads to enable the battery backup system.
    If 0-10v dimming system is available, connect the purple and gray wires to the corresponding purple and gray wires in the building dimming system.

  7. Tuck all loose wires and cables into the housing base (B). Gently press housing base (B) near one end of the fixture while securing the LED cover assembly (A) until all latches securly engages with the housing base (B).

Alternate Mounting Method A: Chain suspension
A. Two slots on both ends of the fixture base (B) can be used to suspend the fixture using the optional hook and chain kit. Insert the “S” hook into the slots as shown, and suspend the other end of the chain to a secure hook location, or use the provided hooks after screwing into a wood mounting surface.ENERGETIC E5SLB Series LED Strip Light - Chain
suspension

Alternate Mounting Method B: Snap clips
B. Align the junction box supply wires to the intended knockout location on the housing base (B), mark off the two locations where the mounting clips should be mounted to the surface to the respective catch locations. Secure the two mounting clips to the intended surface using the supplied wood screws and anchor (if necessary). Snap the fixture body to the mounting clips to secure the fixture and complete the wiring as needed in the prior steps above.ENERGETIC E5SLB Series LED Strip Light - wires to the
intended

Alternate Mounting Method C: Junction Box Cover Plate
C. If the width of the fixture body fails to cover the junction box opening, a junction box cover plate can be used between the fixture and junction box. Mount the JBox cover plate (DD) over the junction box in the intended mounting surface, using the included screws. Ensure that all supply wires have been routed through the center opening.ENERGETIC E5SLB Series LED Strip Light -
Cover Plate

BIR810-B-D Dip Switch Installation Instructions

Parameter Setting By Dip Switch
A. Consider the picture: 1,2 set sensitivity; 3,4 set hold time; 5,6 set the lux; 7,8 stand-by light level; 9,10 set stand-by time.

ENERGETIC E5SLB Series LED Strip Light - Dip Switch

Detection range setting (Sensitivity)
A. Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 8-20ft, pull switch to the ON position as “ ↑”, pull switch to the off position as “ ↓ ”, switch location and detection range of the corresponding table (A)

Sensitivity: Sets the sensitivity of the motion sensor to vary the detection trigger. Reduce sensitivity value to reduce false triggers and filter out negligible motion.

Hold Time setting (Sensitivity)
B. The light can be set to stay ON for an period of time between approx. 10sec and a maximum of 15min. Any movement detected before this time elapse will restart the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test. Pull switch to the ON position as “ ↑ ”, pull switch to the OFF position “ ↓ ”, switch location and detection range of the corresponding table is as seen in Fig. B

Hold-time: Sets the time fixture is to remain in Occupancy-detected state (Lights on) after no motion has been detected.

ZUV700A001 Remote for Occupancy Sensor configuration

Energetic Lighting’s ZUV700A001 remote will configure the occupancy sensors to operate at either a bi-level or tri-level state. Each operational stage can be configured to various light levels as well as desired time durations. Ambient light can also be factored in for daylight harvesting applications. Four custom memory slots are available to store
specific configuration settings for instant upload of new settings.
*Note: The E5SLB series fixtures cannot set the STANDBY DIM level to 10%, and will instead drop the light level to 0% with this setting configured.

Specifications

Stand-by power: <0.5 W
Detection range options: 20%, 50%, 75%, 100%
Persistent on-time duration (hold time): 10sec, 1min, 5min, 10min, 15min,

20min, 30min, 60min
Stand-by period (tri-level on duration):| 1min, 30min, 60min, (bi-level mode)
Stand-by period dimmed state levels:| 10%, 20%, 30%
Ambient light harvestthreashold:| 10 Lux, 30 Lux, 50 Lux, (disabled /always on), active sample
Sensor Type:| High frequency (microwave)
Sensor Frequency:| 5.8 GHz (± 75 MHz)
Maximum Detection Range:| 26-ft x 50-ft (lateral radius x height)
Detection angle:| 30° – 150°
Maximum Mounting Height:| 50-ft
Operating Temperature:| -40°F to 158°F

Detection range profile plot
Please note that the detection profile is symmetrical vertically, and a full 360° overhead.

ENERGETIC E5SLB Series LED Strip Light - profile plot

Operation mode states

ENERGETIC E5SLB Series LED Strip Light - mode states

Remote Controller Operation

ENERGETIC E5SLB Series LED Strip Light - Controller
Operation

BIR810-B-D Dip Switch line up for Remote Control

ENERGETIC E5SLB Series LED Strip Light - Remote
Control

Light Control Setting
C. The Cosen light response threshold can be infinitely from approx. 10-50lux, Pull switch to the ON position as “ ↓”, pull switch to the OFF position as “ ↑ ”, switch location and light-control of the corresponding table is as seen in Fig. C

Daylight Sensor: Sets the minimum lux threshold needed to disable light activation. Ambient light above this threashold value will keep fixture in no- occupancy state (lowest level) regardless of motion detected by sensor. Pressing the button will button will sample the current lux level and set the minimum lux threashold to this level, or set to10, 30, or 50 lux.
Select the button to disable daylight sensor (default). Daylight sensor upper threashold is enabled after pressing the key and choosing between 100, 300, or 500 lux.

ENERGETIC E5SLB Series LED Strip Light - can be
infinitely

Stand-by Lighting Level Setting
D. switch to the ON position as “ ↑ ”, pull switch to the off position as “ ↓ ”, switch location and detection range of the corresponding table (D)

Stand-by period: (Tri-level configuration) DIM: Sets the dimmed light % when no motion is detected, Select 0% for Bi-level configuration

Stand-by Time setting
E. File of switch location and detection distance as follow: file of switch location and detection distance as seen in Fig. E

TIME: Sets the time duration to keep fixture in a dimmed Stand-by state after the no-motion hold time has expired.

CARE AND MAINTENANCE

Clean with a mild, non-abrasive glass cleaner and soft cloth. Do NOT use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure the power is turned off, and any liquid spray should be applied to the cleaning cloth and not sprayed directly onto the fixture itself.

TROUBLESHOOTING

Problem Possible Solution Corrective Action
Fixture does not light. 1. Power is off.

2. Incorrect wire connection.
3. Defective wall switch.| 1. Check circuit breaker or wall switch.
2. Check wire splices.
3. Replace switch.
Circuit breaker trips when light is turned on.| Crossed wires or power wire is grounded out.| Verify wires are correctly connected.

WARRANTY

This fixture is warranted to perform free from defects for five (5) years. If it fails to do so, you may return it with proof of purchase to 13445 12th St., Chino, CA 91710 for replacement.

Printed in China
www.energeticlighting.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

energetic User Manuals

Related Manuals