FEATURES

  • A very compact but powerful “ALL-IN-1” white LED profile with:
  • Integrated manual 25° ~ 50° zoom.
  • 4-blade shutter framing system to make sharp beam cuts.
  • The included gobo holder guarantees crisp gobo projections.
  • High-quality white with extremely high CRI > 96
  • Based on a 150watt WHITE LED 3200K
  • Very silent operation with low noise cooling fan and different presets (live, studio, …)
  • Can be used in full standalone mode without any need for DMX (museums, exhibition booths, …)
  • DMX-controlled: 3 different channel modes for maximum flexibility
  • RDM-functionality for easy remote setup: DMX addressing, channel mode, …
  • Flicker-free TV recordings thanks to the adjustable high LED refresh rate!
  • Four dimmer settings with different behavior & speed.
  • Manual control for dimming, strobe & zoom.
  • OLED display to navigate easily through the setup menu!
  • In case of DMX failure, you can choose between blackout and freeze mode.
  • Lock function to avoid unwanted altering of the settings.
  • Lightweight but rugged housing.
  • 5pin DMX in/outputs + PowerCON TRUE1 compatible in/outputs for easy daisy chaining.

BEFORE USE

  • Before you start using this unit, please check if there’s no transportation damage. Should there be any, do not use the device and consult your dealer first.
  • Important: This device left our factory in perfect condition and well-packaged. It is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual.
  • Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user manual.

Check the contents:
Check that the carton contains the following items:

  • BT-PROFILE WW
  • GOBO HOLDER
  • Power cable
  • Safety cable
  • English operating instructions, other languages can be downloaded from our website.

SAFETY INSTRUCTIONS

The lightning flash with the arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance.
This symbol means: indoor use only
This symbol means: Read instructions
This symbol determines the minimum distance from lighted objects. The minimum distance between light output and the illuminated surface must be more than 1 meters

CAUTION: Do not stare at the operating lamp. May be harmful to the eyes.

  • To protect the environment, please try to recycle the packing material as much as possible.
  • To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
  • To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages.
  • This unit is for indoor use only.
  • Don’t place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign object enters the unit, immediately disconnect the mains power.
  • Locate the fixture in a well-ventilated spot, away from any flammable materials and/or liquids. The fixture must be fixed at least 50cm from surrounding walls.
  • Don’t cover any ventilation openings as this may result in overheating.
  • Prevent use in dusty environments and clean the unit regularly.
  • Keep the unit away from children.
  • Inexperienced persons should not operate this device.
  • Maximum safe ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures.
  • Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
  • Allow the device about 10 minutes to cool down before to start servicing.
  • Always unplug the unit when it is not used for a longer time or before to start servicing.
  • The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country.
  • Check that the available voltage is not higher than the one stated on the unit.
  • The power cord should always be in perfect condition. Switch the unit immediately off when the power cord is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Never let the power cord come into contact with other cables!
  • This fixture must be earthed in order to comply with safety regulations.
  • Don’t connect the unit to any dimmer pack.
  • Always use an appropriate and certified safety cable when installing the unit.
  • In order to prevent electric shock, do not open the cover. Apart from the mains fuse there are no user-serviceable parts inside.
  • Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same type and electrical specifications!
  • In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
  • The housing and the lenses must be replaced if they are visibly damaged.
  • Please use the original packing when the device is to be transported.
  •  Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
    Important: Never look directly into the light source! Don’t use the effect in the presence of persons suffering from epilepsy.

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and/or damage to property. Overhead rigging requires extensive experience! Working load limits should be respected, certified installation materials should be used, the installed device should be inspected regularly for safety.

  • Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
  • Locate the fixture in a well-ventilated spot, far away from any flammable materials and/or liquids. The fixture must be fixed at least 50cm from surrounding walls.
  • The device should be installed out of reach of people and outside areas where persons may walk by or be seated.
  • Before rigging make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
  • Always use a certified safety cable that can hold 12times the weight of the device when installing the unit. This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails.
  • The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
  • Don’t cover any ventilation openings as this may result in overheating.
  • The operator has to make sure that the safety-relating and machine-technical installations are approved by an expert before using them for the first time. The installations should be inspected every year by a skilled person to be sure that safety is still optimal.

DESCRIPTION

  1. MAINS INPUT: equipped with PowerCON® TRUE1 compatible connectors. Connect the supplied mains cable or any PowerCON® extension cable here.

  2. MAINS OUTPUT: used to daisy chain the power to several other projectors. Always pay attention to the maximum load while adding projectors! Special Multi cables (PowerCON® TRUE1 + DMX XLR combined cables are optionally available: see our website!)

  3. VOLTAGE SELECTOR: used to select between 110Vac and 230Vac, please check this switch before the projector is switched on.

  4. MAINS FUSE: protects the unit in case of electrical problems, always use the prescribed fuse!

  5. DMX IN/OUT: 5pin in/outputs are available to daisy chain the projector with other units that will be controlled by a DMX controller.

  6. DISPLAY: shows the various menus and the selected functions.

  7. CONTROL buttons: used to navigate the setup menu to adapt settings and values. If the setup menu is locked, press the following button combination to unlock: ▲, ▼, ▲, ▼, [ENTER]

  8. ZOOM KNOB: used to adjust the size of the light beam or projected gobo, please secure it after use.

  9. FOCUS KNOW: used to focus the beam / projected gobo after the size was adjusted, secure it after use.

  10. FRAMING SHUTTERS: a set of 4 shutter blades that can be used to manually define the shape of the beam.

  11. GOBO HOLDER: to install a standard or custom-made gobo. Open the gobo holder gently and slide the gobo inside. The gobo should have an
    outside diameter of 60mm, while the maximum pattern size can be 55mm. The gobo holder is inserted on the top of the projector, just in front of the upper shutter blade.

  12. HANGING BRACKET: with a knob on both sides to fasten the unit in the desired position. You can use the holes of the bracket to fix a hook or truss clamp.

  13. SAFETY EYE: used to attach a safety cable when the unit is rigged, see paragraph “overhead rigging”.

SETUP MENU / HOW TO SETUP

With the setup menu you can fully configure the projector. All settings are preserved when the unit is disconnected from the mains.
■ [MENU] button: press to enter/leave the setup menu.
► [ENTER] button: press to select/confirm or store the current menu option or value.
▲/▼ [UP/DOWN] button: press to navigate the setup menu or change a value.

MAIN MENU SUB MENU VALUES REMARKS
STATIC WHITE 0 → 255 Master dimmer while working in STATIC mode

(0 → 255)
STROBE| 0 → 25| Set the value of the [STROBE] (0 → 25Hz).
ADDRESS| | 001 – 512| Set the DMX ADDRESS (default 001)

RUN MODE

| DMX| | Sets the mode to DMX control (default mode)
STATIC| | Projector in Stand-alone mode: use the settings in STATIC
SLAVE| | Sets the mode to master/slave
DIMMER PACK| | The projector can be dimmed using an external dimmer pack
AUTO DIM/DMX| | Automatically chooses between DIMMER PACK and DMX

PERSONALITY

| UNO| | 1CH-mode: 8bit dimmer
DOS| | 2CH-mode: 16bit dimmer
STD. P| | 4CH-mode: 16bit dimer + strobe + control channel

SETTING

| RESET| [PASSWORD]| Restore factory settings (extra password to confirm)

DIMMER

| DIM4|

Dimming curves OFF(fast) to DIM4(slow) (DIM4 = default)

DIM3
DIM2
DIM1
OFF
DMX ERROR| FREEZE| Hold after loss of DMX signal (default)
BLACKOUT| Blackout after loss of DMX signal

PWM_RATE

| 1200Hz|

Sets the PWM frequency (1200Hz = default)

2400Hz
4000Hz
6000Hz
25000Hz

FAN MODE

| LIVE| Fan speed is temperature controlled (default)
POWER| Fast fan rotation for maximum light output
STUDIO| Lowest fan noises, output reduced with high temperature.
DISP LOCK| ON| Locks ALL setup menus (default)
OFF| Only the SETTINGS menu (SUB MENU 2) is locked

DISP TIME

| ON| Display backlight always on
10s| Turns off display backlight after 10s
30s| Turns off display backlight after 30s (default)
2min| Turns off display backlight after 120s (default)

INFO

| FIXTURE HOURS| HOURS| Shows the number of hours the fixture was used.
VERSION*| V..    20--| Software version + date of publication
RDM UID| 0x2122004Bxxxx| Check fixture’s ID
RDM LABEL**| BT-PROFILE-WW| Check fixture’s LABEL
All passwords of this product are: , ,, ,

ELECTRICAL INSTALLATION

Important: The electrical installation should be carried out by qualified personnel only, according to the regulations for electrical and mechanical safety in your country.

Electrical installation for two or more units in DMX mode:

  • The DMX protocol is a widely used high-speed signal to control intelligent light equipment. You need to “daisy chain” your DMX controller and all the connected units.
  • Pin layout XLR-3pin: Pin1 = GND ~ Pin2 = Negative signal (-) ~ Pin3 = Positive signal (+)
  •  To prevent strange behavior of the light effects, due to interferences, you must use a 90Ω to 120Ω terminator at the end of the chain. Never use Y-splitter cables, this simply won’t work!
  • Make sure that all units are connected to the mains.
  • Each unit in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode.

USE IN STAND-ALONE (STATIC) MODE

The projector can be used without the need for a DMX controller. The last used setting is preserved when the
projector is switched off.

  • In the setup menu: select [RUN MODE] and choose the option [STATIC]
  • Now you can set the desired output manually.
  • Choose the option [DIMMER] and set the desired light output.
  • If needed, you can also adapt the strobe speeds, leave it to zero if no strobe is needed.

RDM FUNCTIONS / REMOTE SETUP

RDM means “Remote Device Management”. This projector works with a brief set of RDM functions which
means that it can setup a bi-directional communication with an RDM-compatible DMX-controller. Some of
these functions are briefly explained below, others will be added in the future.

  • The DMX-controller sends out a “discovery command”, all RDM devices respond and send their unique device ID.

  • The DMX-controller asks each RDM device for some basic data so it knows which devices are connected.
    The projector will respond:

  • Device name: BT-PROFILE WW

  • Manufacturer: Briteq®

  • Category: LED Dimmer

  • Device name: BT-PROFILE WW

  • Manufacturer: Briteq®

  • Category: LED Dimmer

  • Firmware: x.x.x (firmware version of the projector)

  • DMX address: xxx (current DMX start address of the projector)

  • DMX footprint: xx (number of DMX-channels used by the projector)

  • Personality: xx (current personality [or DMX-working mode] used by the projectors)

  • The DMX-controller can send certain commands to each RDM device which allow remote setup of the Thanks to this the projector can be setup remotely.
    No more need to take a ladder and set all units one by one!

  • DMX START ADDRESS: The start address can be set remotely from 001 to xxx.

  • PERSONALITY: The DMX working mode (DMX-chart) can be set remotely.

  • DIMMER CURVE: choose DIM4 (slow) or ODD (fast)

  • PWM FREQ: choose the desired refresh rate for the LED
    These functions make it possible to prepare a complete DMX-patch of all projectors on the DMX-controller
    and send these data to all projectors at once. More functions will be added later.
    Also the LED temperature can be monitored through RDM.

DMX CHARTS

UNO DOS STD.P Value Function
1 1 1 000-255 DIMMER
2 2 000-255 DIMMER FINE
__

__

3

| | STROBE
000-009| NO FUNCTION
010-099| STROBE FROM (SLOD TO FAST, 0-25Hz)
100-109| NO FUNCTION
110-179| LIGHTNING STROBE
180-189| NO FUNCTION
190-255| RANDOM STROBE
| | __

__

__

__

__

__

4

| | CONTROL (3s before activation)
000-010| NO FUNCTION
011-060| RESERVED
061-070| LIVE
071-080| STUDIO
081-090| POWER
091-100| RESERVED
101-110| DIMMER OFF (fast)
111-120| DIMMER DIM4 (slow)
121-150| RESERVED
151-160| PWM: 1200Hz
161-170| PWM: 2400Hz
171-180| PWM: 4000Hz
181-190| PWM: 6000Hz
191-200| PWM: 25000Hz
201-210| ALL RESET
211-255| RESERVED

MAINTENANCE

  • Make sure the area below the installation place is free from unwanted persons during servicing.

  • Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
    During inspection, the following points should be checked:

  • All screws used for installing the device and any of its parts should be tightly fastened and may not be corroded.

  • Housings, fixations and installation spots (ceiling, truss, suspensions) should be totally free from any deformation.

  • When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.

  • The main cables must be in impeccable condition and should be replaced immediately when even a small problem is detected.

  • In order to protect the device from overheating the cooling fans (if any) and ventilation openings should be cleaned monthly.

  • The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.

  • The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.

  • Clean with a soft cloth using normal glass cleaning products.

  • Always dry the parts carefully.
    Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!

SPECIFICATIONS

This unit is radio-interference suppressed. This product meets the requirements of the current European and national guidelines. Conformity has been established and the relevant statements and documents have been deposited by the manufacturer.

  • Mains Input: AC 100 – 240V, 50/60Hz
  • Fuse: T3.15A / 250V (20x5mm)
  • Power consumption (max): 170 Watts
  • Power connections: PowerCON TRUE1 compatible connector, input / output
  • Power Linking capacity: 10A @ 240V
  • DMX connections: 5 pin-XLR male / female inputs + outputs
  • Lamp: WHITE LED 170W
  • Color Temperature: 3200K
  • CRI: >96
  • Beam Angle: manual zoom 25° ~ 50°
  • IP-Rating: IP20
  • Operating Temperature: 0°C – 45°C
  • Size: See drawing
  • Weight: 6,2 kg