medisana 60065 UHW Air Humidifier
Product Description
- Water tank
- Nebulizer (rotatable)
- ON/OFF switch and nebulizer intensity control dial
- ON/OFF switch for night light
- Float gauge
- Motor opening
- Cleaning brush
- Indicator light
- Ultrasonic transducer (under the perforated ring)
IMPORTANT
Failure to follow these instructions may result in serious injury or damage to
the device. WARNING
These instructions must be followed to prevent possible injury to the user.
CAUTION
These instructions must be followed to prevent possible damage to the device.
NOTE
These instructions provide useful additional information regarding
installation and operation.
Safety Instructions
Please read these instructions for use carefully before using the device, in particular the safety instructions. Keep the instructions in a safe place for future reference. If you give the device away, be sure to include this user manual.
Power Supply
- Before connecting the device to your power supply, ensure that the mains volt-age specified on the type plate corresponds to that of your power supply.
- Only connect the plug to the socket when the device is switched off.
- Never use the power cable to carry, pull or turn the device, and do not pinch the cable.
- Position the power cable so that there is no risk of falling and the risk of strangulation is eliminated.
- Do not handle the plug when standing in water and always handle the plug with dry hands.
Special Persons
- This device may only be used by children over 8 years of age, as well as per-sons with reduced physical, sensory or mental capacities or lack of experience and knowledge, if they are supervised or have been instructed regarding the safe use of the device and understand the hazards resulting from its use.
- Children are not allowed to play with the device.
- In the case of an allergic respiratory illness, consult your doctor before using the device.
- Speak with your doctor if health problems should occur during use. Immediately discontinue use of the device in this case.
Operating the Device
- The device is not intended for commercial use.
- Use the device only for its intended purpose, as directed by the user instructions. In the event of misuse, all guarantees become null and void!
- Do not use the device if the cable or plug are damaged, if it does not work properly, if it has been dropped or dropped into water.
- Keep the device, including the power cable, away from hot surfaces.
- For use, place the device on a solid, flat surface so that it cannot topple over.
- Never attempt to take hold of a device that has fallen into water.
Immediately remove the plug.
- Do not use the device if the water tank is empty or contains insufficient liquid.
- Do not use essential oils (e.g. eucalyptus or menthol) as these can damage the device.
- Keep the ventilation slots on the base of the device free from dust and contaminants.
- Switch off all functions after use and remove the plug from the socket.
For Maintenance and Cleaning
-
You may only clean the device.
In the event of malfunctions, do not proceed with any unauthorized repair of the device. Otherwise, this will render any warranty claims void. Ask your dealer and have repairs done only by medisana services. -
Cleaning and user maintenance must never be carried out by children without supervision.
-
Do not immerse the device into water of other fluids.
-
Should fluid enter the device, immediately remove the plug.
-
Store the device in dry place.
Intended Use
The humidifier serves to increases the relative humidity of a room. The capacity of the device is designed for a room 30 m² in area. The device is only intended for use in the home and not for commercial or medical purposes!
Scope of Delivery
First, check whether the device is complete and is not damaged. If in doubt,
do not operate the device and contact your supplier or service centre.
The contents include:
- 1 medisana air humidifier UHW
- 1 cleaning brush
- 1 instruction manual
The packaging is recyclable or can be recycled back into the raw materials
cycle. Please dispose of unwanted packaging materials properly. If damage
caused during transport is noted while unpacking, please contact your retailer
immediately.
WARNING
Keep packaging away from children! Choking hazard!
Ultrasound Technology
Ambient air which is too dry increases vulnerability to infections and
respiratory diseases and also leads to fatigue as well as lapses in
concentration. Clean air should have a relative humidity of be-tween 40 and
55%. The quiet, energy-saving ultrasonic technology in the humidifier converts
water into a fine mist through vibrations which increases the humidity of the
air. This improves air quality and prevents mucosal membranes and skin from
drying out. The capacity of the device is designed for a room 30 m² in area.
Adjust the humidity level to the size of the room using the nebulizer
intensity control dial 3. Please follow the cleaning and care instructions.
CAUTION
- Excessive intensive use can result in an oversaturation of the ambient air which can precipitate on walls, windows and objects in the room. It is therefore necessary to regularly check using a hygrometer that the relative humidity does not exceed 55%.
- Ensure that the humidifier is secured against toppling over and operated on a moisture-resistant surface. Precipitation/accumulation can occur particularly when using mineral water/aromatic essences. The nebulizer is rotatable. Ensure that the escaping mist is not directed towards other electrical devices, furniture or walls.
Filling and Emptying the Water Tank
Remove the water tank 1 from the device and turn it over. Unscrew the cap.
Rinse out the water tank and then fill it with a maximum 4.2 L of drinking
water. Seal the tank once again by screwing on the cap. Upturn the water tank
and place it back into the device so that it audibly clicks into place. Do not
move the device with a filled water tank. Dispose of the residual water after
use and rinse out the tank with fresh drinking water. Before reusing, fill the
tank with fresh drinking water. If the device is switched off and not used for
a long period, remove the water tank from the device and drain it.
CAUTION
Only use fresh drinking water when using the device. With hard, calcareous
water you can also use demineralized water. Regularly clean the device and
keep free of lime and other contaminants in order to maintain the
functionality of the device.
Switching On and Off
Insert the plug into a properly installed mains socket.
Switch the humidifier on by initially pushing the ON/OFF switch and nebulizer
intensity control dial 3 from OFF to ON. The integrated indicator light (LED)
8 underneath the water tank illuminates green. The light illuminates red when
the water tank is empty.
Continually adjust the connected device, depending on the room requirements,
from the position (lowest fan intensity) to the maximum position (highest fan
intensity). After a few seconds the escaping mist will be visible over the
outlet 2. Switch the device off after use or if only a small amount of water
remains in the tank (the indicator light illuminates red) by setting the
ON/OFF switch and nebulizer intensity control dial 3 to OFF. The device
automatically turns off nebulization when the water tank is empty. The device
is equipped with a blue night light. When the device is switched on, press the
night light ON/OFF button 4. Press the button 4 once again to turn the night
light off.
Operating Period
At maximum setting (300 ml/h) and with a tank filled with 4200 ml of water, the period of operation will last approximately 14 hours.
Troubleshooting
- Device cannot be switched on. (LED not illuminated): Connect plug; check the circuit, socket and fuse.
- There is no mist (LED illuminated red): Fill the water tank.
- There is no mist, but the tank is full: Set the control dial 3 to the maximum position; place the device on an even surface; clean the nebulizer and transducer with the brush supplied and fill the tank with clean water; rinse the device with clean water.
- White deposits: Use clean water or at least 1/2 distilled water / 1/2 fresh tap water. If a fault of the type described cannot be resolved, please contact your service centre.
Cleaning and Care
- With daily use we recommend that the device should be thoroughly cleaned at least every three days. Also clean the device before and after long periods of storage.
- Before cleaning the device, ensure that the device is switched off and the mains plug is disconnected from the socket.
- Remove the water tank from the device and empty out the contents.
- Clean the outside of the device with a damp, soft cloth.
- Do not use any aggressive substances such as, for example, a scouring agent or other cleaning products. This could damage the surface and reduce nebulization.
- The water tank can be thoroughly rinsed out with warm water (>65 °C) or with at least 75% alcohol solution. Clean the nebulizing chamber using an alcohol-soaked cloth and a cotton swab. Ensure that water does not get inside the device.
- The ultrasonic transducer is the most sensitive component in the device. It is important that it is clean and handled with care. Use the supplied brush to free the outlets of debris and particles of dirt. Under no circumstances must metal-lic equipment be used to clean the ultrasonic transducer.
- If the device is not used for a long time, drain the residual water from the water tank and dry the device.
- Lime residue can be removed using a mild descaling agent, e.g. citric acid.
- Store the device in a cool, dry place; ideally in the original packaging.
- Keep the sealing cap from the bottom of the water tank loose to avoid sticking or fixation of the sealing collar.
- To prevent contamination/algae growth from the outset, drain the device and tank prior to long periods of decommission. Disinfect the tank now and then with alcohol solution.
Descaling
When using hard and mineral-rich water, the device must be descaled
regularly. Please only descale using pure citric acid (powder preparation from
the pharmacy)! (No liquid descaling agent! No descaling tablets! No vinegar!)
-
Completely drain the device (tank and base). Ensure that no liquid enters the motor opening via the ventilator
-
Add 4 tablespoons (approx. 100g) of pure citric acid into the tank and top up with 2000ml of 60 °C water. Screw down the tank and gently shake until the citric acid powder has dissolved.
-
Place the tank onto the base. DO NOT SWITCH THE DEVICE ON!
-
Allow the descaling solution to cool in the tank/device (at least 3 hours)
-
Remove the tank and wipe the inside and nebulizer shaft with the appropriate brush (bottle brush, or similar). Pour out the contents of the tank and rinse well.
-
Empty out the base. Ensure that no liquid enters the motor opening 6. Wipe away persistent limescale with the brush provided, a cloth or cotton swabs. Take care around the ultrasonic transducer!
(For light cleaning the perforated ring covering the ultrasonic transducer can be removed and subsequently replaced) -
Rinse the base well (ensure that no liquid enters the motor opening 6)
Disposal
Do not throw this device away in ordinary household waste. Consumers are legally obliged to bring all used batteries, rechargeable or otherwise, whether they contain harmful substances or not, to a collection site in their community so that they can be transferred to the proper channels for disposal. Remove the battery before you dispose of the device. Do not dispose of spent batteries in domestic waste, but in special waste or at a battery collection point at your retailer! Contact your local author-ity or dealer for disposal.
Technical Data
- Name and model: medisana Ultrasound Air Humidifier
- Power supply: 220-240 V~ 50/60 Hz
- Power: approx. 30 W
- Tank capacity: 4,2 L
- Nebulizer capacity: maximum approx. 300 ml/h
- Dimensions: approx. 26.5 x 33 x 20 cm
- Weight: approx. 1.46 kg
- Storage conditions: clean and dry
- Item number: 60065
- EAN number: 40 15588 60065 4
In the interest of continued product improvement, we reserve the right to make
technical and design changes.
The current version of these user instructions can be found at
www.medisana.com
Warranty and Repair Conditions
In case of warranty please contact your specialist shop or the service centre
directly. Should you have to return the device, please state the defect and
enclose a copy of the purchase receipt or invoice.
The following warranty conditions apply:
- All medisana products are guaranteed for 3 years from the date of purchase. In case of a warranty claim, the purchase receipt or invoice must be provided as proof of purchase date.
- Faults due to material or manufacturing defects will be rectified free of charge within the warranty period.
- A warranty service does not extend the warranty period for either the equipment or for replacement components.
- The following are excluded from the warranty:
- any damage caused by improper use, e.g. not following the user instructions.
- damage caused by repair or intervention by the purchaser or unauthorized third parties.
- transport damage that has occurred on the way from the manufacturer to the consumer or has arisen during transit to the service point.
- spare parts that are subject to normal wear and tear.
- Liability for direct or indirect consequential damages caused by the device is also excluded if the damage to the device is recognised as a warranty claim.