Carrier 42TVAB016 Series Air Conditioner Owner’s Manual
- June 9, 2024
- Carrier
Table of Contents
42TVAB016 Series Air Conditioner
Product Information
This is an air conditioner (split type) with an indoor unit
42TVAB016 Series and an outdoor unit 38TVAB016-I. The appliance is
filled with R32 refrigerant. The precautions for safety are
classified as DANGER, WARNING, and CAUTION. The appliance is
intended to be used by expert or trained users in shops, in light
industry and on farms, or for commercial use by lay persons.
Product Usage Instructions
-
Read the precautions in the manual carefully before operating
the unit. -
The appliance shall be installed in accordance with national
wiring regulation. -
Do not install, repair, open or remove the cover. It may expose
you to dangerous voltages. Ask the dealer or specialist to do
this. -
Do not expose your body directly to cool or warm air for a long
time. -
When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the
breaker. -
The air conditioner must be installed, maintained, repaired,
and removed by a qualified installer or qualified service
person. -
Do not use any refrigerant different from the one specified
(R32) for the appliance.
OWNER’S MANUAL
ENGLISH
FRANÇAIS
FRANÇAIS ITALIANO DEUTSCH
PORTUGUÊS POLSKI CESKY
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit 42TVAB016 Series
Outdoor unit 38TVAB016-I
1126250236
PRECAUTIONS FOR SAFETY
Read the precautions in this manual carefully before operating the unit.
This appliance is filled with R32.
Warning indications on the air conditioner unit
Warning indication
Description
CAUTION CAUTION
BURST HAZARD Open the service valves before the operation, otherwise there might be the burst.
BURST HAZARD Open the service valves before the operation, otherwise there might be the burst.
Keep this manual where the operator can easily find it. Read the precautions
in this manual carefully before operating the unit. This appliance is intended
to be used by expert or trained users in shops, in light
industry and on farms, or for commercial use by lay persons. The precautions
described herein are classified as DANGER, WARNING and
CAUTION. They both contain important information regarding safety. Be sure to
observe all precautions without fail.
DANGER
Do not install, repair, open or remove the cover. It may expose you to
dangerous voltages. Ask the dealer or the specialist to do this.
Turning off the power supply will not prevent potential electric shock. The
appliance shall be installed in accordance with national wiring regulation.
Means for disconnection from the supply having a contact separation of at
least
3 mm in all poles must be incorporated in the fixed wiring. The appliance must
be stored in a room without continuously operating ignition
sources (for example, open flames, an operating gas appliance or an operating
electric heater). In order to avoid fire, explosion or injury, do not operate
the unit when harmful gases (e.g. flammable or corrosive) are detected near
the unit.
WARNING
Do not expose your body directly to cool or warm air for a long time. Do not
insert your finger or any article into the air inlet/outlet. When an
abnormality (burning smell, etc.) occurs, stop the air conditioner and
disconnect the power supply or turn off the breaker. This appliance can be
used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
1
PRECAUTIONS FOR SAFETY
This appliance is not intended for use by person (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. The air conditioner must be installed, maintained, repaired and removed by a
EN
qualified installer or qualified service person. When any of these jobs is to be
done, ask a qualified installer or qualified service person to do them for you.
Children should be supervised to ensure that they do not play with the
appliance.
Do not use any refrigerant different from the one specified (R32) for
complement or replacement. Otherwise, abnormally high pressure may be
generated in the refrigeration cycle, which may result in a failure or explosion of
the product or an injury to your body.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
Be aware that refrigerants may not contain an odour.
Do not pierce or burn as the appliance is pressurized. Do not expose the
appliance to heat, flames, sparks, or other sources or ignition. Else, it may
explode and cause injury or death.
CAUTION
Do not wash the unit with water. It may cause an electric shock. Do not use
this air conditioner for other purposes such as preserving food,
breeding animal, etc. Do not step or put anything on the indoor/outdoor unit.
It may cause an injury or
damage the unit. Do not touch aluminium fin because it may cause an injury.
Before cleaning the unit, turn off the main switch or the circuit breaker.
When the unit won’t be used for a long time, turn off the main switch or the
circuit breaker. It is recommended that maintenance be performed by a
specialist when the unit
has been operated for a long time. The manufacturer shall not assume any
liability for the damage caused by not
observing the description of this manual.
2
1 INDOOR UNIT DISPLAY
1 Wi-Fi 2 ECO 3 PURE 4 Timer 5 Operation Mode
Display brightness can be adjusted, follow procedure on 9.
2 PREPARATION BEFORE USE
Preparing Filters 1. Open the air inlet grille and remove the air filters. 2.
Attach the filters. (see detail in the Installation Manual).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover. 2. Insert 2 new batteries (AAA type)
following the (+) and () positions.
Remote Control Reset 1. Remove the batteries.
2. Press
.
3. Insert the batteries.
3 AIR FLOW DIRECTION
1
Press
FIX : Move the
louver in the desired vertical
direction.
2
Press
FIX : Move the
louver in the desired horizontal
direction.
SWING operation can be selected from MENU button
MENU
Vertical (Up-Down) swing
Swing off
V
Vertical
(Up-Down) Swing
Horizontal (Left-Right) swing
Horizontal
3
H
(Left-Right) Swing
V
Vertical and
H
Horizontal Swing
HADA Care flow
HADA CARE FLOW
H.DA
Note:
Do not move the louver manually by others. The louver may automation
positioning by some operation mode.
4 REMOTE CONTROL
1 Infrared signal emitter
1
2 Start/Stop button
3 Mode select button
4 Temperature button
5 Fan speed button
6 Menu select button
7 Set louver Up-Down button
8 Set louver Left-Right button
9 Check button*
*Check button under battery cover
2
4
9
3
MODE
5
FAN MENU
6
7
FIX FIX
8
5 COOLING / FAN ONLY / OPERATION
1. Press MODE : Select Cool , or Fan only .
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
Fan Only: No temperature indication
3. Press MED+
FAN : Select AUTO, LOW , LOW+ , MED ,
, HIGH
or Quiet
6 AUTOMATIC OPERATION
To automatically select cooling or fan only operation 1. Press MODE : Select Auto A.
2. Press
3. Press MED+
: Set the desired temperature. Min. 17°C, Max. 30°C.
FAN : Select AUTO, LOW , LOW+ , MED ,
, HIGH
or Quiet
7 DRY OPERATION
For dehumidification, a moderate cooling performance is controlled
automatically.
1. Press MODE : Select Dry .
2. Press
: Set the desired temperature. Min. 17°C, Max. 30°C.
Note: DRY mode fan speed is set to Auto only.
3
8 MENU SETUP
For select more setting of Air conditioner such as Louver select Hi Power, OFF
Timer and other use MENU button
MENU ,
8.1 LOUVER SWING and HADA CARE FLOW OPERATION
Comfortable air flow can select from feature.
Louver swing opearation:
To distribute air flow in both vertical and horizontal by swing the louver
automatically.
HADA care flow operation: Air flow upward to the ceiling, provide Indirect air
flow to body and
homogenize room temperature. Note:
During HADA CARE FLOW mode, FIX button cannot active.
Louver Swing and HADA Care Flow Operation Setting
1. Press MENU button for enter menu selection
MENU
Blink
°C
During triangle mark blink can select menu by press TEMP. button.
EN
MODE FAN MENU FIX FIX
2. Enter Louver set by press MENU button again. triangle mark will stop blink and setting feature will be blink instead.
MENU
Blink
°C 3. Select Louver swing or HADA CARE FLOW by press TEMP. button.
°C
Swing off
V
Vertical
(Up-Down) Swing
V
Vertical and
H
H Horizontal
Swing
Horizontal (Left-Right)
Swing
HADA CARE FLOW
H.DA
4. Confirm selected feature by press MENU button again. MENU
°C
When feature had selected will return to menu selection display triangle mark
will blink . 5. Leave from menu setting display by select exit and press menu
button
MENU
°C
°C Leave from menu setting to normal display (no triangle and feature blink).
4
8.2 SILENT OPERATION (Outdoor Unit)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the cooling capacity
will be optimized to deliver such silent experience. The silent operation can
be selected from one of two purposes (Silent 1 and Silent 2). There are three
setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Cooling capacity is still prioritized to ensure
having sufficient comfort inside the room.
This setting is a perfect balance between the Cooling capacity and the Sound
level of outdoor unit.
Silent 2:
Compromising the Cooling capacity to the Sound level in any circumstance where
the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit.
Note: While activating of Silent operation, inadequate cooling capacity may
occur.
Silent Operation Setting 1. Press MENU button for enter menu selection
MENU
Blink
8.3 Hi POWER OPERATION
Hi-P
To automatically control room temperature and airflow for faster cooling
operation (except in DRY and FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to select
Hi POWER
MENU
Blink both triangle and °C feature mark Feature not
yet set
2. Confirm selected feature by press MENU button again.
MENU
Blink only triangle Feature
°C
already set
3. Leave from menu setting display by select EXIT.
°C
°C
During triangle mark blink
can select menu by press TEMP. button.
Blink both triangle and
feature mark Feature not
°C
yet set
2. Enter SILENT set by press MENU button. triangle mark will stop blink and
setting feature will be blink instead.
MENU
°C 3. Select SILENT operation by press TEMP. button.
°C
SILENT#1
SILENT#2
None
8.4 ECO OPERATION
ECO
To automatically control room temperature to save energy (except in DRY and
FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to select
ECO
MENU
Blink both triangle and
°C
feature mark Feature not
yet set
2. Confirm selected feature by press MENU button again.
MENU
Blink only triangle Feature °C already set
3. Leave from menu setting display by select EXIT.
MENU
°C
Note: Cooling operation; the set temperture will increase automatically 1
degree/hour for 2 hours (maximum 2 degrees increase).
4. Confirm selected feature by press MENU button again. MENU
Blink only triangle Feature already set °C
When feature had selected will return to menu selection display triangle mark
will blink 5. Leave from menu setting display by select EXIT.
MENU
°C
5
8.5 TIMER OFF OPERATION To set the timer OFF when the air conditioner is
operating. 1. Press MENU button for enter menu setting and press TEMP. button
to
select TIMER OFF.
MENU
Blink both triangle and feature mark Feature not °C yet set
2. Enter TIMER set by press MENU button. triangle mark will stop blink and
setting feature will be blink instead.
MENU
3. Select TIMER OFF by press TEMP. button. Can select TIMER OFF from 0.5 –
12hrs.
8.6 PLASMA ION OPERATION
PURE
Capture efficiency of floating impurities in the air is accelerated by plasma
ion contaminates such as bacteria, odor, smoke, dust and virus are caught and
deactivated by Plasma Ion.
1. Press MENU button for enter menu setting and press TEMP. button to select
PURE
MENU
Blink both triangle and
°C
feature mark Feature not
yet set
2. Confirm selected feature by press MENU button again.
MENU
EN
°C
Blink only triangle Feature
already set
3. Leave from menu setting display by select EXIT.
MENU
4. Confirm TIMER OFF by press MENU button.
MENU
Blink only triangle Feature already set °C
5. Leave from menu setting display by select EXIT.
MENU
°C
Note: Plasma Ion operation dose not remove harmful substances from cigarette
smoke (carbon monoxide etc.). Open a window occasionally for ventilation.
8.7 POWER-SELECTION OPERATION
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%, 75%,
or 50% and can be implemented by POWER-SELECTION. The lower percentage, the
higher saving and also longer compressor lifetime. Due to the reason that
POWER-SELECTION function limits the maximum
current, inadequate cooling capacity may occur. 1. Press MENU button for enter
menu setting and press TEMP. button to select
POWER-SEL
MENU
°C
Note: The setting will be saved for the next same operation.
Cancel TIMER OFF 6. During TIMER OFF already set (no.5) press MENU button and
press
TEMP. button to select TIMER OFF.
MENU
Blink only triangle Feature already set °C
7. Press MENU button again will cancel TIMER OFF.
MENU
Blink both triangle and feature mark Feature not yet set °C
8. Leave from menu setting display by select EXIT.
MENU
°C
°C Blink only triangle
2. Enter POWER-SEL setting by press MENU button again.
MENU
°C 3. Select POWER-SEL level by press TEMP. button.
°C
100%
75%
50%
4. Confirm POWER-SEL level by press MENU button.
MENU
°C 5. Leave from menu setting display by select EXIT.
MENU
°C
6
9 DISPLAY LAMP BRIGHTNESS ADJUSTMENT
To decrease the display lamp brightness or turn it off.
1. Press and hold
FAN for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press
Remote control LCD
Rise or
Decrease
to adjust brightness in 4 levels.
Operation display
Brightness
Lamp illuminates full brightness.
100%
50% Lamp illuminates 50% brightness.
50% Lamp illuminates 50% brightness and the operation lamp is turned off.
All lamps are turned off.
All turned off
In the examples of and , the lamp illuminates for 5 seconds before going off.
13 REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly. Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON. 2.
Point the remote control at the indoor unit. 3. Push and hold button on the
back side of Remote Control “00” will be
shown on the display. (Picture 1) 4. Press MODE during pushing . “B” will show
on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote Control
B is memorized. (Picture 2) Note: 1. Repeat above step to reset Remote Control
to be A. 2. Remote Control A has not “A” display. 3. Default setting of Remote
Control from factory is A.
1
2
10 AUTO RESTART FUNCTION SETTING
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position. Turn it
OFF if this function is not required.
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep
sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds (3 beep
sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note : In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
11
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the 30 seconds.
more 2 times within
12 TEMPORARY OPERATION
In case of the misplaced or discharged remote control Pressing the RESET
button, the unit can start or stop without using the remote control. Operation
mode is set on AUTOMATIC operation, preset temperature is 24°C and fan
operation is automatic speed.
14 OPERATION AND PERFORMANCE
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of plastic.
Air conditioner operating conditions
Operation Cooling Dry
Temp. Outdoor Temperature
10°C ~ 46°C 10°C ~ 46°C
Room Temperature
21°C ~ 32°C 17°C ~ 32°C
15 MAINTENANCE
Firstly, turn off the circuit breaker. Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when needed.
No benzine, thinner, polishing powder or chemically-treated duster. Air
filters Clean every 2 weeks.
1. Open the air inlet grille. 2. Remove the air filters. 3. Vacuum or wash
and then dry them. 4. Reinstall the air filters and close the air inlet
grille.
16 TROUBLESHOOTING (CHECK POINT)
The unit does not operate. Cooling or Heating is abnormally low.
The power main switch is turned off.
The circuit breaker is activated
to cut off the power supply. Stoppage of electric current ON timer is set.
The filters are blocked with dust. The temperature has been set improperly.
The windows or doors are opened. The air inlet or outlet of the outdoor
unit is blocked. The fan speed is too low. The operation mode is FAN or DRY.
POWER SELECTION function is
set 75% or 50% (This function is depend on remote controller).
7
R32
TH
CAUTION
BURST HAZARD Open the service valves before the operation, otherwise there
might be the burst.
3 .
(
)
)
( )
1
8
(R32) ( )
2
1
1 Wi-Fi 2 ECO 3 PURE 4 5
9
2
1. 2. ()
() 1. 2. 2 ( AAA) (+) (-)
1. 2. 3.
3
FIX : 1
FIX : 2
(-) MENU
V
(-)
(-)
H
(-)
3
V
–
H
–
H.DA
:
4
1
2 –
3
4
5
6
7 –
8 –
9 *
2
- 3
9
5
7
1
MODE FAN MENU FIX FIX
TH
4
6 8
5 /
1. MODE :
: 17°C 30°C
:
3. FAN : AUTO, LOW , LOW+ , MED ,
MED+ , HIGH
Quiet
6
, 1. MODE : Auto A
2. 3.
MED+
: 17°C 30°C
FAN : AUTO, LOW , LOW+ , MED ,
, HIGH
Quiet
7
1. MODE :
: 17°C 30°C
: AUTO
3
8
(Hi Power) MENU
H.DA 1. (MENU)
MENU
°C
(TEMP)
2. (MENU) (Louver set) (Setting feature)
MENU
°C
3. (TEMP) H.DA
MODE
FAN MENU
FIX FIX
8.1 H.DA : (V) (H) H.DA: : FIX H.DA
°C
V
(-)
V H
–
– H
(-)
H.DA
4. (MENU)
MENU
°C
5. “EXIT”
MENU
°C
°C
( )
4
8.2 () () (Two purpose) ( 1 2) : > 1 > 2 1 :
() 2 : () : 1. (MENU)
MENU
°C
(TEMP)
°C
2. (MENU) (SILENT)
(Setting feature)
MENU
°C
3. (TEMP)
°C
5. “EXIT”
MENU
°C
8.3
Hi-P
TH
(Faster cooling operation) ( (DRY and FAN ONLY) ) 1. (MENU)
(Hi POWER)
MENU
°C
2. (MENU)
MENU
°C 3. “EXIT”
°C
8.4
ECO
( (DRY and FAN ONLY) ) 1. (MENU) (TEMP)
(ECO)
MENU
°C
2. (MENU)
MENU
°C 3. “EXIT”
MENU
1 #2
4. (MENU)
MENU
°C
: : 1 / 2 ( 2 )
°C
5
8.5 1. (MENU)
MENU
°C
2. (MENU) (TIMER)
(Setting feature)
MENU
3. (TEMP) 0.5 12
8.6
PURE
(Odor) 1. (MENU) (TEMP)
(PURE)
MENU
°C
2. (MENU)
MENU
°C
3. “EXIT”
MENU
4. (MENU)
MENU
°C 5. “EXIT”
MENU
°C
: 6. ( 5.) (MENU) (TEMP)
MENU
°C 7. (MENU)
MENU
°C
8. “EXIT”
MENU
°C
: ( ) 8.7
100%, 75% 50% POWER-SELECTION
1. (MENU) (TEMP)
MENU
°C
2. (MENU)
MENU
°C
3. (TEMP)
°C
100%
75%
50%
°C
6
4. (MENU)
MENU
°C
5. “EXIT”
MENU
°C
9
1. FAN 3 ( , ,
)
4
LCD
12
RESET AUTO 24°C
13 A-B TH
B
1. RESET 2. 3. “00”
( 1) 4. MODE “B”
“00” B ( 2) : 1. A
2. A “A” 3. A
100%
50% 50%
1
2
50%
50%
5
10
()
Auto Restart ON
Auto Restart [Operation] 3
( 3 Operation )
Auto Restart [Operation] 3
( 3 Operation 5 5 ) : AUTO RESTART
14
1. 2.
3:ON3
/
(Cool)
-10°C ~ 46°C -10°C ~ 46°C
21°C ~ 32°C 17°C ~ 32°C
15
2
1. 2. 3. 4.
16 ()
11 ( )
“”
“” 30
2
30
7
(OFF)
FAN DRY POWER SELECTION
75% 50% ( )
1126250236