PARRY GDFP Double Pedestal Gas Fryer User Manual
- June 10, 2024
- PARRY
Table of Contents
- GDFP Double Pedestal Gas Fryer
- Product Overview
- Safety Instructions
- Installation Instructions
- Technical Data
- Operating Instructions
- Cleaning Instructions
- Maintenance Instructions
- Fault Finding
- Service Information
- Warranty Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PRODUCT INSTRUCTIONS
Double Pedestal Gas Fryer
GDF/GDFP
British Built for Purpose.
GDFP Double Pedestal Gas Fryer
Welcome to Parry at
Parry ie one of the UK’s foramost manufacturers of high-quality Stainless
Steel Fabricated Products with a 40-year heritage rooted in British
craftsmanship.
At Parry, quality and service are second nature. Striving to exceed our
customers’ expectations is not just our motto; it’s the very heartbeat of our
business. Our commitment to our customers is reflected in the Parry 4E
Standard Inspection Body stating that all our products are:Our ranges of Stainless Steel
Products have been specifically designed with the consumer in mind and are
tailored and compliant to your specific industry sector. All our products are
4E Compliant and meet EU & UK regulations, where applicable. The Parry brand
stands for quality, reliability and value.
Our British designed products have been created by our expert in-house
development team and manutactured to exacting standards using Industry
specified grade of European stainless steel and holding relevant EU & UK
certification for all product.
1$09001 certification and continual investrnent in the training and
development of our highly skilled, artisan workforce means that our clients
have genuine peace of mind that they are buying hand crafted, quality products
supported by five-star customer service. All Parry products meet EU
regulations for their respective sector.
We are LEAN manufacturers, minimising waste, maximising productivity. We are
proud to run an operation that is committed to minimising our impact on the
environment.
Our equipment and fumiture are manufactured in our 45,000 sq ft manufacturing
facility in Draycott, Derbyshire in England’s industrial heartland. Products
are made to order if not available in our stocked items which means you can
choose from 600 products, offering over 3,500 variants, with short lead times
to suit your specific needs. That means you get exactly what you need when you
nead it. Our product information can be found here, in our brochure or on our
website www.parry.co.uk. You have my personal
commitment that Parry will exceed your expectations. Should you have any
questions please contact your distributor. Alternatively, our customer
services team will be happy to help you on 01332 875544. Mark Banton MBA
Managing Director Parry Catering Equipment (Midlands) Ltd, Town End Road,
Draycott, Derby, DE72 3PT.
Sales Tel: 01332 875544
Product Overview
The Parry GDF gas double pedestal fryer is the ideal choice for commercial caterers looking for a robust, reliable and easy-to-use solution. The freestanding fryer features two large baskets and powerful burners, making it perfect for frying fish, chicken, chips and doughnuts in takeaways, restaurants or other professional catering establishments.
It leads the industry in:
Design and aesthetic appeal
Performance
Power
Functionality
After sales support
Features | GDF/P |
---|---|
Unpacked weight (kg) | 110 |
Packed Weight (kg) | 130 |
Dimensions (w x d x h) mm | 600 x 790 x 970 |
KW — Natural KW — Propane | 19.05 |
20.93
BTU — Natural BTU — Propane| 91,100
94,618
Input Gas Connection
GAS INPUT PRESSURE — Natural GAS INPUT PRESSURE – Propane| 1/4″ BSP Female
20 mbar
37 mbar
Can be converted using conversiones| Yes
Warranty| 2 years
Safety Instructions
IMPORTANT
PLEASE READ INSTRUCTIONS FULLY BEFORE USE INSTALLATION INSTRUCTIONS
IMPORTANT- YOUR ATTENTION IS DRAWN TO THE GAS SAFETY REGULATIONS. THIS
APPLIANCE MUST ONLY BE USED IN A WELL VENTILATED AREA. IT IS RECOMMENDED THAT
A MINIMUM AREA OF 450mm² PER 1 Kw (3400 Btu/HR) OF TOTAL INPUT MUST BE
ALLOWED. PARTICULAR ATTENTION SHOULD BE PAID TO THE SUPPLY OF CLEAN FRESH AIR
AT LOW LEVEL TO THE APPLIANCE.
Attention is drawn to the requirement of the fryer to be fixed to the floor by
means of fixing holes in the flanged feet.
The data plate on the rear of the appliance must be checked to ensure the
appliance is suitable for the gas supply available. This appliance must be
installed in accordance with the rules in force.
Read the user instructions, read the installation instructions and ensure the
correct ventilation requirements are met. Attention should also be drawn to
the need for regular
servicing.
In normal use parts of the catering equipment may become hot, suitable
precautions must be taken to avoid accidental burns, therefore the appliance
should be positioned to
minimise the risk of accidental touching. It is the responsibility of
supervisors to warn users of this and ensure the operators of this equipment
are trained in safe operation of this appliance. It is recommended the
appliance be fitted below a ventilating hood, preferably of the extractor
type, incorporating a grease filter.
All commercial gas catering equipment is recommended to be mounted below an
extraction canopy. Please consult a ventilation engineer or refer to
Guidelines DW172 to calculate the ventilation requirements for cooking areas
containing different pieces of gas catering equipment.
Installation Instructions
POSITIONING
The appliance must not be installed on or against combustible surfaces –
minimum clearances must be:
Rear 150mm (6”)
Sides 150mm (6”) FROM ANY ADJACENT WALL
It is recommended that the appliance be sited below a ventilating hood
preferably of the extractor type incorporating a grease filter.
The minimum distance between the top of the appliance and any over shelf or
ceiling constructed of combustible material must be 1525mm (60”). All local
fire regulations must be observed before the appliance is commissioned the gas
safety regulations require that all gas connections on the gas line are tested
for gas soundness between the gas meter and the appliance. All packing and
protective film must be removed from the panels etc. prior to commissioning
the appliance.
GAS CONNECTION
The gas connection is ½” B.S.P.T. on the left hand side rear of the fryer. The
supply pipe must not be less than ½”, an easily accessible isolation cock
should be fitted in the pipework as close as possible to the fryer. An
approved flex may be used in conjunction with a straining cable.
Gas hoses used to connect the appliance to the gas supply must be of the
correct specification for the gas and pressure of the appliance. The gas hose
must comply with the
national requirements in force, and be CE marked, of a metal braided
construction suitable for commercial catering equipment. The hoses should be
periodically examined and replaced as necessary The tube or hose shall be
fitted such that there are no sharp bends or torsional strain which may cause
damage or failure of the tube or hose, especially near the end fittings.
Torsional strain can be prevented by the use of internal unions, swivel
joints, etc. The bend radius should not exceed that stated by the
Manufacturer. The hose should not touch the ground and should be no longer
than 1.5m long.
A manual valve should be positioned upstream of the tube or hose unless the
connection fitting incorporates a self-sealing quick release coupling. Where a
quick release coupling is used for horizontal travel such as in commercial
catering appliances it is advisable that the coupling is facing downwards to
prevent the ingress of debris and ensure the hose is formed in to a smooth
curve. All units should have a restraining cable fitted preventing the unit
from being pulled away from the wall and causing the gas hose to become
disconnected accident
Technical Data
TEST DATA GDF FRYER
GAS | TOTAL HEAT INPUT (NETT) | TOTAL GAS RATE |
---|---|---|
NATURAL GAS G20 @ 20mbar | 19.05 kW | 2.02 M3 /hr |
PROPANE GAS G31 @ 37mbar | 20.97 kW | 0.86 M3 /hr |
GAS | INJECTOR | PILOT INJECTORS |
NATURAL GAS G20 @ 20mbar | INJECT0230 | PINJ76378 |
PROPANE GAS G31 @ 37mbar | INJECT0160 | PINJ76371 |
GAS | PILOT RATE (Per Side) | FULL RATE (Per Side) |
NATURAL GAS G20 @ 20mbar | 0.055 M³/HR | 1.008 M³/HR |
PROPANE GAS G31 @ 37mbar | 0.015 M³/HR | 0.429 M³/HR |
Operating Instructions
USER INSTRUCTIONS
The attention of the user is drawn to the current Gas Safety (Instructions and
Use) Regulations in force. This appliance must be used in accordance with
these, also the need
for regular servicing which must be carried out by a competent and qualified
person.
SAFETY NOTE
Some parts and surfaces of this appliance can get hot in use. It is the
responsibility of the Kitchen Supervisor to inform and warn every user of this
and to ensure the user wears any necessary protective clothing when operating
the fryer.
LIGHTING INSTRUCTIONS
WARNING: DO NOT LIGHT BURNERS WHEN THE PAN IS EMPTY
- Open the compartment door, ensure the drain valves are closed and check the level of cooking oil (between maximum and minimum markings). The oil required to fill the pan to the correct level is 12 litres per pan.
- Turn on the gas supply.
- Turn the thermostat to position 1.
- Turn top control knob anticlockwise until stops, Press control knob in and turn anticlockwise to Ignite pilot. If pilot fails to ignite, repeat the procedure until pilot is lit. Hold knob in for 20-30 seconds to ensure pilot flame is fully established.
- Release the knob and turn fully anticlockwise to main burner position.
- Turn the thermostat dial to theappropriate setting (Please note if using solidified oil or fat follow the steps below)
NOTE: LIDS SHOULD NOT BE USED WHILST FRYING
SHUT DOWN OF THE FRYER
- When appliance is not required for cooking, turn control knob clockwise to the pilot setting this will leave the fryer ready for the next time. Turn back to main burner setting once required and adjust thermostat to the required setting.
- To turn the unit off completely, turn the control knob clockwise to the off position and turn off gas supply.
USE OF SOLIDIFIED OIL OR FAT
-
In an empty pan
IMPORTANT: If solidified oil or fat is to be used, remove the grid from the bottom of the pan, break the solidified oil or fat into small pieces and fill the V shaped bottom of the pan. Light the appliance and turn the thermostat knob to 130˚C (Setting 2). Continue to add pieces of fat into the pan until the V shaped bottom is filled with the molten fat. If the fat appears to be overheating, turn the thermostat OFF, continue to add fat and turn the thermostat ON when the fat has cooled.
Refit the grid and put the remaining oil or fat into the pan until the level is up to the mark. Allow to heat up slowly until all the fat has melted, then turn the thermostat knob to the required cooking temperature. -
Already solidified in the pan
Light the appliance and turn the thermostat ON for approximately 5-10 seconds, and then turn OFF again. Leave it for 30 seconds before repeating the 5-10 seconds cycle. Continue to repeat until the fat has melted so that any remaining un-melted pieces are free floating, then turn the thermostat to the required temperature.
COOKING INSTRUCTIONS
With the thermostat knob turned to the required cooking temperature, allow
the oil or fat to heat up for about 20 minutes before starting to cook. After
each load is removed from the fryer always allow 2½ minutes for the
temperature of the oil to recover before the next load is put into the oil.
THE FRYING MEDIUM
Ensure oil is always maintained at the level indicated. Good quality vegetable
oil is recommended. The life expectancy of oils will be lengthened if they are
filtered regularly –
food particles not removed turn rancid and reduce oil quality. The life of the
oil will also be extended if the temperature is turned down when the fryer is
not is use.
“Please note also, using old oil will reduce the flash point and therefore
present a greater fire hazard and be more prone to surge boiling. Attention
should also be drawn to the effect of over-wet food and too large a charge on
surge boiling”.
Chip Frying
The recommended load for each batch is 1.4 kg (3 lbs) for each basket. This
will fill the basket about 2/3 rdfull and it is important that this load
should not be exceeded.
Fish Frying
Cook fish by free floating them. Four or five 100g pieces may be cooked at one
time. Slide the fish into the pan slowly to avoid splashing of the oil or fat
and prevent the fish sinking and sticking to the base of the pan.
Cooking Chart – the following chart is for guidance only.
Maximum basket load not to exceed 3 lbs
Food | Time | Temperature |
---|---|---|
Chicken pieces | 5-8 mins | 175°C |
Chipped potatoes (Blanched) | 3 mins | 165°C |
Chipped potatoes (Browning) | 1-2 mins | 190°C |
Chipped Potatoes (Raw) | 4-5 mins | 190°C |
Doughnuts | 3-4 mins | 170°C |
Fish fillets | 5-7 mins | 175°C |
Fritters | 3-4 mins | 175°C |
Potato Chips | 2 mins | 190°C |
Scampi | 3-4 mins | 175°C |
Temperature Settings
STAT No. | Temperature |
---|---|
1 | 120°C |
2 | 135°C |
3 | 145°C |
4 | 160°C |
5 | 175°C |
6 | 185°C |
7 | 195°C |
ALL THE ABOVE ARE +/- 5°C
To Obtain Best Results
- Keep the pan clean
- Use good quality oil or fat which has high breakdown temperature
- Use only clean oil or fat and strain daily.
- Maintain the oil or fat at the correct level
- Do not start to fry until the oil has reached the correct temperature
- Do not exceed the temperature of the oil or fat as recommended by the supplier.
- Do not overload the fryer.
- Remove the crumbs or pieces floating on the surface of the oil.
- When using frozen foods follow the food manufacturers cooking instructions carefully
- To conserve energy, turn the thermostat knob to the OFF position during breaks in frying.
Cleaning Instructions
Drainage
- Always allow the oil to cool to a maximum 55˚C before draining.
- Remove the blanking nut from drain tap, fit discharge pipe into tap, drain oil into suitable receptacle, taking care not to overfill so that it is not difficult to handle.
- Excess oil in the base of the tank can be removed with kitchen paper.
- For best results oil should be drained and filtered every day the fryer had been used.
- This will prolong the life of the oil.
Cleaning – The appliance should be cleaned after every use
- Isolate the appliance from the gas supply.
- Allow oil to cool to maximum 55˚C.
- Drain as per instructions for draining.
- Wash tank and top surface of the fryer body.
- Clean the drain tube assembly, using a tube or flue brush suitable for 15mm tube, with the drain tap in the open position. Clean by inserting brush into inlet and outlet of drain tube.
- Wash all parts thoroughly.
- Ensure all parts are thoroughly rinsed and dried. To ensure there is no water left in the drain tube, flush with a small amount of clean cooking oil.
- Re-assembly in reverse order.
- Stainless steel cleaners maybe used on the exterior of the unit and cleaning instructions on the product must be adhered to.
- Never clean the unit with water jets.
Maintenance Instructions
Ensure the appliance is isolated from the power supply before installing,
cleaning or maintaining the appliance.
Maintenance and service must only be undertaken by a qualified
electrician.
Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts. For more information on buying spares visit: www.parry.co.uk/parry-commercial-catering-spares
ROUTINE MAINTENANCE
To be done by engineer
- Ensure fryer is filled with oil.
- Fit pressure gauge to multifunction valve and go through lighting procedure, check flame failure device opens in no more than 30 seconds.
- Turn thermostat to 150°C and check that the pressure at the test point is:
NATURAL GAS
20mb ( 8” W.G.)
PROPANE GAS
37mb (14” W.G.)
Adjust governor if necessary.
Only leave burner on for a minimum amount of time to ensure fryer does not get
too hot.
- Turn the thermostat to off and ensure the burner has extinguished completely within 3-4 seconds
- Turn the thermostat on again to 150°C and ensure the burner cross lights smoothly from the pilot.
- Check burner flames are uniform and there is no spillage of the flames away from the heat exchanger.
- Turn the thermostat off and blow out the pilot. Check that the flame failure valve closes within 60 seconds. This can be done by feel or sound.
- Turn off the gas, remove pilot and withdraw burner assembly, clean the burner parts and ensure the injectors are clear.
- Reassemble the pilot and main burners.
- Go through the lighting up procedure, turn the thermostat to 150°C and allow to heat up. Check the thermostat cuts out the gas, turn the thermostat to 190°C, allow to heat up and note the oil temperature is 190°C+5°C.
Fault Finding
Malfunction 1 | Test and Probable Cause | Solution |
---|---|---|
Piezo Ignitor not sparking | Piezo Ignitor not sparking | Replace Lead |
Fractured Electrode Insulator | Replace Electrode | |
No spark being generated at all. | Replace Piezo | |
Pilot burner will not light or stay lit | Thermocouple / interrupter | |
connections not secure | Tighten Connection |
TEST: Is there gas at the point when holding the control knob in the pilot
position:|
Yes| Check over temperature stat for
open circuit and then check thermocouple voltage (min. 15mv)
Yes, Very Little| Check supply, then check pilot jet for blockages and clean
if necessary.
No| Check Supply.
If all the above are ON| control valve is faulty
Over temperature stat operates| Check if the temperature is over 220°C| If
not’ Control Stat
TEST: Check if the control stat operates on temp. rise when set point is low /
100°C|
If yes, check calibration of the control stat. (See Installation instructions
for details)| Manually reset over temperature stat
If not working| Replace Control stat then
manually reset over temperature stat.
Service Information
This appliance should be routinely serviced to prolong its lifetime. Parry
recommends that the appliance is serviced every 12 months by a Parry
authorised engineer. Failure to service your product within the initial 12
month warranty period will cause the 24 month warranty to become void.
If the supply cord becomes damaged, it must be replaced by the manufacturer,
it’s service agent, or a similarly qualified person.
Enhanced 2 Years Warranty
Parry Catering (Midlands) Ltd offer an enhanced warranty of two years
(including parts and labour) on all of the Parry manufactured products. To
take advantage of this you should register you warranty by logging onto the
company website and filling out our simple form. www.parry.co.uk/the-parry-
warranty
If you have any issues with your product and wish to request a warranty call
you can contact our friendly team who will organize a Parry approved service
engineer to attend and fix your problem.
All warranty requests can be sent to
warranty@parry.co.uk alternatively call our
warranty department for technical assistance on 01332 875544
Exploded View
Parts List
Main Assembly
Part Number | Description | Code |
---|---|---|
1 | Bottom LH Hinge | ULT6BOHINGEBL |
2 | Hinge Pin Bush | ULTHINGEBUSH |
3 | Hinge Pin Bush | ULTHINGEBUSH |
4 | Top LH Hinge | ULT6BOHINGETL |
5 | Gland Nipple | NIPP67061 |
6 | Gland Disc | DISC67061 |
7 | Graphite Seal | SEAL07000 |
8 | *Body | *NO CODE |
9 | *Batter Plate | *NO CODE |
10 | Fryer Basket | BASKETGFR |
11 | Plastic Handle | HANDLBASK |
12 | *Lid | *NO CODE |
13 | Tee Knob | TEEKNOB |
14 | *Flue Cover | *NO CODE |
15 | *Inner Flue | *NO CODE |
16 | 12mm Equal Tee | FRYERTE12 From April 2021 use GDFGASRAIL |
16a | 12mm Equal Elbow | GDF12ELBOW From April 2021 use GDFGASRAIL |
17 | 12mm Inlet Pipe | NEWFRYERPIPE From April 2021 use GDFGASRAIL |
18 | 15mm – 12mm Reducing Set | REDS1512F From April 2021 use GDFGASRAIL |
19 | 15mm x ½” BSP Connector | CONNECT15 From April 2021 use GDFGASRAIL |
16, 16a, 17, 18, 19 | Gas Rail Assembly | GDFGASRAIL |
20 | Leg Plate | LEGPLATE |
21 | Adjuster Boss | ADJM12 |
22 | Hex Leg | LEG50-100HEX |
23 | Drain Valve | ULTVALVE1 |
24 | Drain Valve Cap | ULTFRYBLANK |
25 | *Drip Guard | *NO CODE |
26 | Roller Catch Bracket | LCPP4BODOORKEEP |
27 | Roller Catch Assembly | *NO CODE |
28 | Door Handle | GB6HANDLE |
29 | *LH Door Assembly | *NO CODE |
Parts List
Burner Assembly
Part Number | Description | Code |
---|---|---|
1 | 15mm x 3/8 BSPT | GDF15ADAPT |
la | 15mm — 12mm Reducing Set | REDS1512F |
2 | 8mm x”/. Tapper Compression | |
Coupling | COUPLE8MM | |
3 | Manifold Strap (Part of | |
MANIFOLD1) | ||
4 | Injector Manifold | MANIFOLD1 |
5 | Burner Injector | NAT Gas = INJECT0230 |
LPG Gas = INJECT0160
6| Over Temperature Thermostat| TMST07000
7| Burner| BURNR7000
8| Universal Thermocouple| THCP900MM
9| Pilot Assembly cw Electrode & Pilot
Injector| Setup for LPG gas PILOT7000ADJ-LPG Setup for NAT gas PILOT7000ADJ-
NAT
10| Pilot Injector
(If required without pilot assembly)| NAT Gas = PIN176378
LPG Gas = PINJ76371
11| Pilot Bracket| NO CODE
12| Burner Carriage| NO CODE
13| GV30 Gas Valve| VALVEGDSF
14| 8mm x 3/8 BSPT| GDFSADAPT
15| 6mm Pilot Shear Nut| VALVEGDFFITT
16| Interrupter| VALVETHCINT
16a| Interrupter Lead| GDSFINTLEAD
17| 6mm Pilot Pipe| GFPILOTPIPE
18| 8mm Burner Pipe| GFBURNERPIPE
| GV30 Gas valve Blanking Plugs| VALVEGDFPLUG
*Metalwork components
Replacement Parts
REPLACEMENT OF ALL PARTS SHOULD BE CARRIED OUT BY A QUALIFIED ENGINEER
PILOT JET AND ELECTRODE
Undo pilot feed from gas valve, undo thermocouple from valve, remove screw
from pilot bracket, pilot assembly, c/w thermocouple and ignitor can now be
removed.
THERMOCOUPLE
Undo thermocouple from gas valve; release probe end from the bracket on the
pilot assembly. Fit new in reverse order.
CONTROL THERMOSTAT
- Drain fryer
- Remove screws from mounting bracket
- Remove the thermostat gland nut
- Release thermostat phial from clip inside tank
- Pull stat through tank, there will be some resistance felt due to the packing gland being compacted.
- Re-assemble in reverse order
CONTROL VALVE
- Disconnect the gas supply pipe work and pipe to burners.
- See previous notes for removal of pilot/thermocouple assembly, also thermostat assembly.
- Remove screws securing valve to bracket.
- Remove fittings from valve to fit into replacement valves, as these are not supplied with new valve.
- Refit in reverse order.
SAFETY THERMOSTAT
- Drain fryer
- Remove spade connections on thermostat
- Remove the two screws securing thermostat to bracket
- Undo the gland nut on the tank and withdraw thermostat phial from bracket, through the wall of the tank.
- Fit new thermostat in reverse order.
Warranty Information
The manufacturer’s warranty is only valid in the UK mainland. Northern
Ireland, Western Isles, Inner Hebrides and Islands are parts only warranty.
Please be aware that the warranty starts from the date of purchase from Parry
and not the sale or installation date of the equipment.
To be eligible for a 2 year warranty, products must be serviced at least once
within the first 12 months of purchase.
All service calls will be carried out between 8am and 5pm, Monday to Friday.
Your warranty is invalid if your equipment has not been installed in
accordance with the manufacturer’s instructions. The misuse, alteration or
unauthorised repairs of the equipment will also invalidate the warranty.
During the warranty period it is at Parry’s discretion whether to repair or
replace the equipment.
The warranty only applies if the equipment has been used in a professional
manner following the manufacturer’s instructions and maintenance guidelines.
The warranty covers defects in the material and component failure only. We are
not liable for trading loss, loss of perishable items, water damage or loss
due to injury or fire damage.
Please ensure you have referred to the manufacturer’s instruction before
placing a warranty call.
Contact our warranty department on 01332 875544 for technical assistance.
Please have your model number ready before calling.
All warranty requests must be submitted to
warranty@parry.co.uk.
Failure to pay any warranty charges will result in your warranty being put on
hold until the bill has been settled. Any issues regarding the raised charges
should be put in writing to our warranty department for further investigation.
Register your product by visiting our website
www.parry.co.uk
Not covered under warranty
- Fault due to incorrect installation, poor maintenance or equipment abuse.
- Resetting of equipment or circuit breakers.
- Faulty electrics – e.g. customer’s plug socket, plug, wiring, junction box fault, wrong fuse.
- Products must be serviced within the first 12 months to be eligible for the 2 year warranty
- Product not covered by warranty if combustible materials have been used, e.g. plastic trays.
- Foil used on racks, blockages and lime scale issues.
- Failure to grant access for pre-arranged service call.
- Equipment that has been set up or used incorrectly e.g. dishwasher detergents, levelling and setting up of doors on a six burner cooker.
- Excessive carbon build-up on griddle plates or overuse of lava rock on chargrills. (Recommended use by Parry no more than 2kg.)
- All of the above points are not covered by warranty and any costs incurred, because of the above, will be forwarded to the parties responsiblefor placing the call.
Disposal & Recycling
The packaging should be disposed of in accordance with the regulations in
force.
Parry-British Built for Purpose
IN274-4
References
- Commercial Catering Equipment & Clinical Equipment | Parry
- Parry Commercial Catering Spares - Parry
- Warranty Claim Page - Parry