PARRY PGF600G Propane Gas Griddle Instructions
- June 4, 2024
- PARRY
Table of Contents
- PGF600G Propane Gas Griddle
- Product Overview
- Safety Instructions
- Installation Instructions
- Operating Instructions
- Cleaning Instructions
- Maintenance Instructions
- Conversion Instructions
- Technical Details
- Fault Finding
- Service Information
- Exploded View
- Parts List
- Warranty Information
- Disposal & Recycling
- Documents / Resources
PRODUCT INSTRUCTIONS LPG Gas Griddles
PGF600G/PGF800G/PGF1000G
British Built for Purpose.
PGF600G Propane Gas Griddle
Welcome to Parry
Parry is one of the UK’s foremost manufacturers of high-quality Stainless
Stee! Fabricated Products with a 40-year heritage rooted in British
craftsmanship.
At Parry, quality and service are second nature. Striving to exceed our
customers’ expectations is not just our motto; it’s the very heartbeat of our
business. Our commitment to our customers is reflected in the Parry 4E
Standard Inspection Body stating that all our products are:Our ranges of Stainless Steel
Products have been specifically designed with the consumer in mind and are
tailored and compliant to your specific industry sector. All our products are
4E Compliant and meet EU & UK regulations, where applicable. The Parry brand
stands for quality, reliability and value.
Our British-designed products have been created by our expert in-house
development team and manufactured to exacting standards using Industry
specified grades of European stainless steel and holding relevant EU & UK
certifications for all products.
1809001 certification and continual investment in the training and development
of our highly skilled, artisan workforce means that our clients have genuine
peace of mind that they are buying hand-crafted, quality products supported by
five-star customer service. All Parry products meet EU regulations for their
respective sector.
We are LEAN manufacturers, minimizing waste, and maximizing productivity. We
are proud to run an operation that is committed to minimizing our impact on
the environment.
Our equipment and furniture are manufactured in our 45,000 sq ft manufacturing
facility in Draycott.
Derbyshire in England’s industrial heartland. Products are made to order if
not available in our stocked items which means you can choose from 600
products. offering over 3.500 variants, with short lead times to suit your
specific needs. That means you get exactly what you need when you need it.
Our product information can be found here, in our brochure or on our website
www.parry.co.uk.
You have my personal commitment that Parry will exceed your expectations.
Should you have
any questions please contact your distributor. Alternatively, our customer
services team
will be happy to help you on 01332 875544.
Mark Banton MBA
Managing Director
Product Overview
The stainless steel Parry LPG Gas Griddle range feature superior quality
stainless steel burners and a natural gas conversion kit, making the range
ideal for mobile catering use.
The units are exceptionally easy to clean thanks to a drip tray included with
all models. Please note that the gas hose and regulator not included.
| PGF600G| PGF800G| PGF1000G
---|---|---|---
Unpacked weight (kg)| 22.5| 29| 35
Packed weight (kg)| 25| 32| 57
Dimensions (w x d x h) mm| 620 x 470 x 200| 820 x 470 x 200| 1020 x 470 x 200
Warranty| 2 years| 2 years| 2 years
KW – Natural KW – Propane/Butane| n/a 5.5| n/a 8.25| n/a 9.3
BTU – Natural BTU – Propane/Butane| n/a 18,766| n/a 28,149| n/a 31,732
Input Gas Connection| ½” BSP Male| ½” BSP Male| ½” BSP Male
GAS INPUT PRESSURE – Natural GAS INPUT PRESSURE – Propane GAS INPUT PRESSURE –
Propane/Butane| 20bar 37bar 28bar| 20bar 37bar 28mbar| 20bar 37bar 28mbar
Can the unit be converted using a conversion kit| Yes| Yes| Yes
The units lead the industry in:
Design and aesthetic appeal
Performance
Power
Functionality
After-sales support
Safety Instructions
SAFETY INSTRUCTIONS
IMPORTANT, PLEASE READ THE INSTRUCTIONS FULLY BEFORE USING THIS APPLIANCE
IS ONLY FOR PROFESSIONAL USE AND MUST ONLY BE USED BY QUALIFIED PEOPLE.
Attention should be drawn to the fact that parts of this unit by necessity,
will get VERY HOT, and will cause burns if touched accidentally. Therefore, it
is the responsibility of the supervisor or equivalent to provide SUITABLE
PROTECTIVE CLOTHING for the user. THIS APPLIANCE MUST BE FITTED AND TESTED BY
A REGISTERED FITTER BEFORE USE. The unit should be installed in compliance
with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force at
the time. Particular attention should be paid to the Gas Safety (Installation
and Use) Regulations and the Health and Safety at Work Act. Each appliance
requires a flow of fresh air for combustion. Under no circumstances should air
vents on the appliances, or air vents installed by the fitter in the room of
the appliance to supply combustion air, be altered or omitted in any way. To
prevent shocks, all appliances whether gas or electric, must be earthed. ANY
GAS CONVERSIONS NEEDED TO BE MADE TO THE PRODUCT MUST BE CARRIED OUT BY A GAS
SAFE REGISTERED ENGINEER To avoid scratching the highly polished exterior
surface of this equipment whilst in transit, the protective film on the
exterior surfaces has NOT been removed. It is IMPORTANT that the protective
film is removed from the unit prior to use.
Installation Instructions
THIS APPLIANCE MUST BE FITTED AND TESTED BY A REGISTERED FITTER IN ACCORDANCE
WITH CURRENT REGULATIONS EACH APPLIANCE REQUIRES A FLOW OF FRESH AIR FOR
COMBUSTION, UNDER NO CIRCUMSTANCES SHOULD AIR VENTS ON THE APPLIANCES, OR AIR
VENTS INSTALLED BY THE FITTER IN THE ROOM OF THE APPLIANCES TO SUPPLY
COMBUSTION AIR, BE ALTERED OR OMITTED IN ANY WAY.
All appliances are supplied for use on L.P.G gas (conversion to NAT is
possible with a conversion kit available). Working pressures and heat inputs
are listed in the Technical Details.
Appliances must not be installed on or against any combustible surface.
Clearances are appliances must be:
CEILING/SHELF 900mm
REAR 150mm
SIDES 150mm
During installation provision must be made for combustion air supply to the
appliance, which enters the appliance through the base and rear of the
appliance,
this should not be blocked at any time. SEE TECHNICAL DETAILS.
Appliances are designed to be installed, on Parry Catering Equipment for
stability, if they are fitted on any other surface they should be suitably
secured, to prevent excessive movement.
Connection to the appliance is by ½” BSPT at the left-hand side of the
appliance. The pressure test point is located underneath the appliance – it is
located on the tap rail.
low rate is factory set for LPG gas, and only requires adjustment when
converting from LPG to NAT Gases.
Remove all protective film before use.
Ensure whoever is operating the appliance is fully conversant with its
operation and aware of the dangers involved in the incorrect operation and
cleaning, especially the danger of burns and scolds from the cooking medium
and hot surfaces of working areas.
- The appliance must be placed in a well-ventilated location, underneath a suction fan with a suction capacity of at least 1500m3/h
- The griddle must be secured by placing four M10-sized screws with at At least 15mm of thread is available.
- In the shape of a rectangle, holes should be drilled on the work surface for the location of where the feet will sit
- Screws will be placed through the work surface so the feet of the appliance can sit directly on top of the screws so the appliance can not move
- Sizes required : GGP6.4 295mm x 332mm
- Sizes required : GGP6.6 295mm x 532mm
- Sizes required : GGP6.8 295mm x 732mm
- Sizes required : GGP6.10 295mm x 932mm
IMPORTANT: After installing the appliance, make sure that it has a downward inclination (higher on the back), so that all the juices are drained into the drip tray.
Operating Instructions
FOR FITTING INSTRUCTIONS SEE THE INSTALLATION SECTION.
ALL GRIDDLES ARE FITTED WITH A FLAME FAILURE DEVICE FOR SAFETY AND SPARK
IGNITION FOR EASE OF LIGHTING
TO LIGHT BURNER:
Turn the knob to position
Push the knob in and ignite gas by pressing the ignition button to left of the
on/off knob.
Keep the ON/OFF knob pressed in for 15-20 seconds. Check gas is lit by looking
through the gap between the plate and the front panel of the appliance.
Release the ON/OFF knob, gas should stay lit, if gas goes out repeat (2) the
burner is now on.
If the unit fails to light within 1 minute, abort the lighting process for at
least 2 minutes to allow gas to disperse.
Turn the knob anti-clockwise to obtain the main gas
The lowest setting has been set at the factory and sealed. This must not be
adjusted by the user.
To turn the burner off, turn the knob in a clockwise direction all the way
round to We advise that the appliance should not be left unattended when
switched on.
The appliances are designed for professional use by qualified people only.
There are no user-serviceable parts.
It is recommended that Griddles be run on full gas after ignition for 10
minutes, then adjust as necessary to obtain correct cooking temperature.
To remove any residue, use a scraper several times a day after cooking.
Scaling will result if this is not done. Empty the fat drawer and clean every
day.
Cleaning Instructions
The appliance should be cleaned after every use.
Allow unit to cool down before cleaning
Always clean the griddle plate and fat drawer after use.
Wipe down the machine with hot soapy water using a soft cloth, do not use
abrasive materials.
Cleaning of the griddle plate it may be necessary to use a griddle stone to
remove carbon build up. Once this has been done seasoning of the plate will be
necessary.
Stainless steel cleaners maybe used on the exterior and cleaning instructions
on the product must be adhered to.
Never clean the unit with water jets.
Maintenance Instructions
Ensure the appliance is isolated from the power supply before installing,
cleaning or maintaining the appliance.
Maintenance and service must only be undertaken by a qualified electrician/gas
engineer.Parry
Catering provides a complete after-sales service by offering the sales of
spare parts directly to customers. Buying spares straight from the
manufacturer allows customers to experience exceptional value and speedy
delivery on all spare parts.
For more information on buying spares visit: www.parry.co.uk/parry-
commercial-catering-spares
In order to clean or replace the burner, loosen the nut that connects the
(8mm) gas pipe to the aluminum part;
Loosen the nut that connects the thermocouple to the aluminum part and
disconnect the piezo ignitor
In case there a tap malfunction, you should replace and there should be no
attempt to oil it.
YOU MUST CLEAN THE COMPONENTS OF THE UNIT AT LEAST ONCE A YEAR
Conversion Instructions
Close the gas supply valve.
Disconnect the inlet gas supply.
To replace the burner, push it a bit to the back of the equipment and this
loosens the burner from the aluminum part. Replace the old burner with a new
one or replace the injector in case of a change of gas type. To loosen the
injector, one must use an adequate nut driver. Attention: Keep in mind the
relation between the diameter of the injector’s hole and the type of gas.
To replace the thermocouple and the electrode it is necessary to take out the
front panel. To do so, loosen the screws that attach the side panels’ corners.
This way the
whole assembly; front panel and corners will come out together.
The thermocouple and the electrode are attached to the aluminum part, which is
attached to the burner support. In order to take out the aluminum part, it’s
necessary
to unscrew the pipe that links the tap to the burner and the 2 screws that
hold the burner frontal support.
The minimum setting is regulated with the burner on turned to the minimum
setting.
Remove the black knob from the gas tap and regulate the frontal screw which is
located below the shaft of the tap.
Adjust the flame to a desired low setting that will have enough heat to keep
the thermocouple hot and keep the flame burning.
Wait for a couple of minutes to make sure that the flame doesn’t go out.
Technical Details
PGF600G (GGP6.6)
Total Unit
GAS | OPERATING PRESSURE | TOTAL HEAT INPUT |
---|---|---|
NATURAL G20 | 20mb/8” W.G. | 5.500 KW = 18767 Btu/h |
BUTANE G30 | 29mb/11.2” W.G. | 5.500 KW = 18767 Btu/h |
PROPANE G31 | 37mb/14.8” W.G. | 5.500 KW = 18767 Btu/h |
G25 | 25mb/10” W.G. | 5.000 KW = 17061 Btu/h |
GAS RATE | M³/HR | FT³/HR |
--- | --- | --- |
NATURAL G20 | 0.582 M³/HR | 20.553 FT³/HR |
BUTANE G30 | 0.184 M³/HR | 6.505 FT³/HR |
PROPANE G31 | 0.243 M³/HR | 8.565 FT³/HR |
G25 @ 25mb | 0.615 M³/HR | 21.719 FT³/HR |
INJECTORS
Natural G20 = INJECT 115
Butane G30 = INJECT 85
Propane G31 = INJECT 85
G25 @ 25mb = INJECT 115
PGF800G (GGP6.8)
Total Unit
GAS | OPERATING PRESSURE | TOTAL HEAT INPUT |
---|---|---|
NATURAL G20 | 20mb/8” W.G. | 8.250 KW = 28150 Btu/h |
BUTANE G30 | 29mb/11.2” W.G. | 8.250 KW = 28150 Btu/h |
PROPANE G31 | 37mb/14.8” W.G. | 8.250 KW = 28150 Btu/h |
G25 | 25mb/10” W.G. | 7.500 KW = 25591 Btu/h |
GAS RATE | M³/HR | FT³/HR |
--- | --- | --- |
NATURAL G20 | 0.872 M³/HR | 30.794 FT³/HR |
BUTANE G30 | 0.276 M³/HR | 9.747 FT³/HR |
PROPANE G31 | 0.364 M³/HR | 12.864 FT³/HR |
G25 @ 25mb | 0.922 M³/HR | 32.560 FT³/HR |
INJECTORS
Natural G20 = INJECT 115
Butane G30 = INJECT 85
Propane G31 = INJECT 85
G25 @ 25mb = INJECT 115
GAS | OPERATING PRESSURE | TOTAL HEAT INPUT |
---|---|---|
NATURAL G20 | 20mb/8” W.G. | 9.300 KW = 31733 Btu/h |
BUTANE G30 | 29mb/11.2” W.G. | 9.300 KW = 31733 Btu/h |
PROPANE G31 | 37mb/14.8” W.G. | 9.300 KW = 31733 Btu/h |
G25 | 25mb/10” W.G. | 8.700 KW = 29686 Btu/h |
GAS RATE | M³/HR | FT³/HR |
--- | --- | --- |
NATURAL G20 | 0.990 M³/HR | 34.962 FT³/HR |
BUTANE G30 | 0.303 M³/HR | 10.692 FT³/HR |
PROPANE G31 | 0.399 M³/HR | 14.142 FT³/HR |
G25 @ 25mb | 1.050 M³/HR | 37.080 FT³/HR |
INJECTORS
Natural G20 = INJECT 125
Butane G30 = INJECT 93
Propane G31 = INJECT 93
G25 @ 25mb = INJECT 125
Fault Finding
Fault | Check | Solution |
---|---|---|
Unit will not light | Check gas supply | Ensure gas supply is turned ON to |
appliance.
| Check to see if a spark is being generated when piezo is pressed.| If piezo
is faulty, contact your distributor.
Unit lights but will not stay lit| Ensure you press and hold the control
knob in for around 10 seconds.| If the problem still persists, please contact
the distributor.
Service Information
This appliance should be routinely serviced to prolong its lifetime. Parry
recommends that the appliance is serviced every 12 months by a Parry
authorized engineer. Failure to service your product within the initial
12-month warranty period will cause the 24-month warranty to become void.
If the supply cord becomes damaged, it must be replaced by the manufacturer,
it’s service agent, or a similarly qualified person.
Enhanced 2 Years Warranty
Parry Catering (Midlands) Ltd offer an enhanced warranty of two years
(including parts and labour) on all of the Parry manufactured products. To
take advantage of this you should register you warranty by logging onto the
company website and filling out our simple form. www.parry.co.uk/the-parry-
warranty
If you have any issues with your product and wish to request a warranty call
you can contact our friendly team who will organize a Parry-approved service
engineer to attend and fix your problem.
All warranty requests can be sent to
warranty@parry.co.uk alternatively call our warranty
department for technical assistance on 01332 875544
Exploded View
Parts List
Part Number | Description | Code |
---|---|---|
1 | 7.0.302.0060 | GRILL PLATE GGP6.6 |
1 | 7.0.303.0060 | GRILL PLATE GGP6.8 |
1 | 7.0.304.0060 | GRILL PLATE GGP6.10 |
2 | 4.0.301.0010 | SLEEVE ø19×1.5×33 mm |
GL500
3| 4.0.301.0011| SLEEVE DRIVE ø19×1.5×33 mm GL500
4| 7.0.301.0001| LEFT PANEL GL500
5| 7.0.301.0002| RIGHT PANEL GL500
6| 7.0.302.0012| FRONT PANEL GGP6.6
6| 7.0.303.0012| FRONT PANEL GGP6.8
6| 7.0.304.0012| FRONT PANEL GGP6.10
7| 7.0.302.0006| REAR PANEL GGP6.6
7| 7.0.303.0006| REAR PANEL GGP6.8
7| 7.0.304.0006| REAR PANEL GGP6.10
8| 4.0.201.0001| COURNER GL
9| 4.0.301.0028| IGNITOR FASTON 2.8×0.5
10| 7.0.301.0020| FRONT BURNER SUPPORT SBF
11| 4.0.100.0010| TAP HANDLE STICHER
12| 7.0.301.0021| REAR BURNER SUPPORT
SBF
13| 4.0.301.0031| INJECTOR SUPPORT
14| 7.0.302.0030| STRUCTURE
REINFORCEMENT GL500.6
14| 7.0.303.0030| STRUCTURE REINFORCEMENT GL500.8
14| 7.0.304.0030| STRUCTURE REINFORCEMENT GL500.10
15| 7.0.120.0030| DISTRIBUTION PIPE SUPPORT
16| 4.0.301.0030| BURNER SBF 300MM
17| 4.0.301.0001| HANDLE FOR GAS TAP GL
18| 7.0.302.0070| DISTRIBUTION TUBE GGP6.6
Part Number| Description| Code
---|---|---
18| 7.0.303.0070| DISTRIBUTION TUBE GGP6.8
18| 7.0.304.0070| DISTRIBUTION TUBE GGP6.10
19| 4.0.000.0878| ADHERENT RUBBER FOR
FEET
20| 7.0.100.0050| DISTRIBUTION TUBE FASTENER
21| 4.0.100.0035| GAS TAP FASTENER
22| 4.0.301.0025| TAP WITH SECURITY VALVE
23| 4.0.301.0032| BURNER SUPPORT SBF
24| 4.0.301.0034| IGNITION PILOT SBF
25| 4.0.301.0012| PLATE REAR SUPPORT ø15×34.5mm GL500
26| 4.0.301.0033| GAS TERMOCOUPLE 250MM FASTON 8X1
27| 4.0.301.0045| GAS INJECTOR M6x0.75 – 1.25 (GGP6.4, GGP6.10)
27| 4.0.301.0044| GAS INJECTOR M6x0.75 – 1.15 (GGP6.6, GGP6.8)
28| 4.0.301.0043| GAS INJECTOR M6x0.75 –
0.93 (GGP6.4, GGP6.10)
28| 4.0.301.0042| GAS INJECTOR M6x0.75 – 0.85 (GGP6.6, GGP6.8)
29| 4.0.301.0035| SBF IGNITION PILOT FIXING SPRING
30| 7.0.302.0027| DRAIN TRAY GL500.6
30| 7.0.303.0027| DRAIN TRAY GL500.8
30| 7.0.304.0027| DRAIN TRAY GL500.10
31| 4.0.065.0004| HANDLE WITH THREAD M6
32| 4.0.066.0087| GAS GRILL PLATE FEET
33
| ****
4.0.301.0036
| CONNECTION TUBE TAP/INJECTOR (G1/4F- M12x1)
Warranty Information
The manufacturer’s warranty is only valid in the UK mainland. Northern
Ireland, Western Isles, Inner Hebrides and Islands are parts-only warranty.
Please be aware that the warranty starts from the date of purchase from Parry
and not the sale or installation date of the equipment.
To be eligible for a 2 year warranty, products must be serviced at least once
within the first 12 months of purchase.
All service calls will be carried out between 8am and 5pm, Monday to Friday.
Your warranty is invalid if your equipment has not been installed in
accordance with the manufacturer’s instructions. The misuse, alteration or
unauthorized repairs of the equipment will also invalidate the warranty.
During the warranty period it is at Parry’s discretion whether to repair or
replace the equipment.
The warranty only applies if the equipment has been used in a professional
manner following the manufacturer’s instructions and maintenance guidelines.
The warranty covers defects in the material and component failure only. We are
not liable for trading loss, loss of perishable items, water damage or loss
due to injury or fire damage. Please ensure you have referred to the
manufacturer’s instructions before placing a warranty call. Contact our
warranty department on 01332 875544 for technical assistance. Please have your
model number ready before calling. All warranty requests must be submitted to
warranty@parry.co.uk.
Failure to pay any warranty charges will result in your warranty being put on
hold until the bill has been settled. Any issues regarding the raised charges
should be put in writing to our warranty department for further investigation.
Register your product by visiting our website
www.parry.co.uk
Not covered under warranty
Fault due to incorrect installation, poor maintenance or equipment abuse.
Resetting of equipment or circuit breakers.
Faulty electrics – e.g. customer’s plug socket, plug, wiring, junction box
fault, wrong fuse.
Products must be serviced within the first 12 months to be eligible for the 2
year warranty
Product not covered by warranty if combustible materials have been used, e.g.
plastic trays.
The foil used on racks, blockages and lime scale issues.
Failure to grant access for a pre-arranged service call.
Equipment that has been set up or used incorrectly e.g. dishwasher detergents,
leveling and setting up of doors on a six burner cooker.
Excessive carbon build-up on griddle plates or overuse of lava rock on
chargrills. (Recommended use by Parry no more than 2kg.)
All of the above points are not covered by warranty and any costs incurred,
because of the above, will be forwarded to the parties responsible for placing
the call.
Disposal & Recycling
Packaging should be disposed of according to the regulations in place.
Parry-British Built for Purpose
IN205-4
Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby,
DE72 3PT.
Sales
Tel: 01332 875544
Fax: 01332 874455
Documents / Resources
|
PARRY PGF600G Propane Gas
Griddle
[pdf] Instructions
PGF600G, PGF800G, PGF1000G, Propane Gas Griddle
---|---
References
- Commercial Catering Equipment & Clinical Equipment | Parry
- Parry Commercial Catering Spares - Parry
- Warranty Claim Page - Parry
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>