GOODWE LX F12.8-H-20 Residential Smart Inverter Solutions User Guide

July 31, 2024
GOODWE

LX F12.8-H-20 Residential Smart Inverter Solutions

“`html

Specifications:

  • Product Name: Residential Smart Inverter Solutions

  • Models Available: Lynx Home F (G2), Lynx Home D, GW5KL-ET,
    GW6KL-ET, GW8KL-ET, and more

  • Battery System: GM3000

  • Smart Devices: Smart meter, Smart Dongle, Smart Energy
    Controller

  • CT Ratio: 120A/40mA

Product Usage Instructions:

01 Networking:

Ensure proper connection of the battery system, smart meter,
smart dongle, and smart energy controller as per the model
description.

02 Power On/Off:

Follow the power on/off instructions specific to the inverter
model being used.

03 Installations:

Install the components based on local laws and regulations.
Refer to the wiring diagram for correct setup.

04 Wiring Diagram:

Follow the wiring diagram for ET 5-10kW (single or parallel
connected) setups with Lynx Home F or Lynx Home D and corresponding
accessories like GM3000 or SEC1000S.

05 Equipment Commissioning:

  1. Download SolarGo APP or ProMate for PC.
  2. Open the APP and follow the prompts to connect the device.
  3. Configure network settings, safety code, BAT connect mode,
    working mode, and advanced parameters as needed.

Frequently Asked Questions (FAQ):

Q: How do I configure the network settings?

A: Tap Home > Settings > Communication Setting >
Network Settings to set network parameters. Ensure proper
configuration for seamless operation.

Q: Can I add new equipment to the power plant?

A: Yes, you can create power plants and add equipment via the
SEMS Portal app. Scan the QR code to add a new equipment and enter
relevant information based on the actual situation.

Q: Where can I get technical support for the product?

A: For technical support and inquiries, contact GoodWe
Technologies Co., Ltd. at service@goodwe.com or visit their website
at www.goodwe.com.

“`

Residential Smart Inverter Solutions
ET 5-10kW+Lynx Home F / Lynx Home D Quick Guide

V1.1-2024-06-07

01 Networking

WARNING

The information in this quick guide is subject to change due to product updates or other reasons. This guide cannot re-

place the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions in the manual are for guidance only.

01 Networking

Device Battery system
Smart meter Smart Dongle Smart Energy Controller

Model

Description

Lynx Home F (G2) LX F9.6-H-20 LX F12.8-H-20 LX F16.0-H-20 LX F19.2-H-20 LX F22.4-H-20 LX F25.6-H-20

Lynx Home F ,F Plus LX F6.6-H LX F9.8-H LX F13.1-H LX F16.4-H

Lynx Home D LX D5.0-10

· A maximum of 8 battery systems can be clustered in a system.
· Do not mix connect battery systems of different versions.

GM3000

· Only for single inverter. · GM3000: GM3000 and the CT, which cannot
be replaced, are included in the inverter package. CT ratio: 120A/40mA.

· Wi-Fi Kit · 4G Kit-EC or 4G Kit-AU

· For single inverter or parallel connected inverters.
· A smart dongle is required for each inverter in the parallel system.

SEC1000S

· Only for the parallel system. A maximum of 10 inverters can be parallel connected.
· GM3000 integrated.

02 Power On/Off

Device Inverter

Model

Description

GW5KL-ET, GW6KL-ET, GW8KL-ET, GW10KL-ET, GW5KN-ET, GW6.5KN-ET, GW8KN-ET, GW10KN- ET, GW5K-ET, GW6.5K-ET, GW8K-ET, GW10K-ET

Power on/off

1

2

3

4

5

6

: Install or not based on local laws and regulations.

1

03 Installations 2

3

04 Wiring Diagram
ET 5-10kW (single) + Lynx Home F or Lynx Home D+ GM3000 + WiFi/4G
4

ET 5-10kW (parallel connected) + SEC1000S
5

Battery System Wiring Diagram 6

05 Equipment Commissioning

SolarGo APP

ProMate (for PC)

Download and open the APP, follow the prompts to connect the device.

SEMS Portal app

Quick Settings

Click SolarGo APP Home>Settings>Quick Settings to complete quick settings step by step. Installer password: goodwe2010

Setting the Safety Code

Setting the BAT Connect Mode

Configuring the Network

Tap Home > Settings > Communication Setting > Network Settings to set network

parameters.

WiFi Kit

4G Kit-EC or 4G Kit-AU

After configuring the APN, unplug the Bluetooth module and insert the 4G Kit EC or 4G Kit AU module.

1

2

Setting the Working Mode

Setting the Advanced Parameters (single inverter only)
Tap Home > Settings > Advanced Settings to set the following functions. Setting the Power Limit Function

The function is disabled by default,if you need DRED/Remote Shutdown/RCR function, enable it.
Enable Three-phase Unbalanced Output when the utility grid company adopts phase separate billing.

Configuring the SEC1000S (parallel system only)

Connect the SEC1000S and PC using a network cable, and configure the two on the same network segment. Default IP of the SEC1000S: 192.168.1.200.

Start ProMate and click DataLogger > LAN Configuration to fill in the IP inforamtion. Click Connect to connect the

ProMate and the SEC1000S.

Setting the network Setting number of the inverter

of the data logger

connected to the COM port

Setting the DRED for parallel system
Setting the power limit for parallel system

Setting the RCR for parallel system

7

Creating a Power Plant Create power plants and add equipments via SEMS Portal app.
Enter the plant information based on actual situation.

Scan the QR code to add a new equipment.

2 1

Add a new equipment

8

GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District,
Suzhou, 215011, China www.goodwe.com
service@goodwe.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals