PARRY Modular Extraction Canopies Instruction Manual

June 4, 2024
PARRY

PARRY Modular Extraction Canopies

PARRY-Modular-Extraction-Canopies-PRODUCT

SYMBOLS UTILIZED IN THIS MANUAL

  • Read the instructions before using the equipment.
  • Important Safety Instructions. Hazard Risk in case of no compliance.
  • Useful guidelines for the user.
  • Instructions for certified technicians only.

Safety and Appropriate Use

Safety Instructions
The equipment is safe to use and complies with the European safety norms in Effect. However, inappropriate use can lead to personal injuries and material damage. To ensure correct and safe functioning, please read this manual before first use. This manual contains important warnings about installation, safety, usage, and maintenance required by this equipment.

Keep this manual for future reference. Deliver the manual along with the equipment in case of passing it to a new owner. The manufacturer cannot be held accountable by damages resulting of inappropriate use and installation. Please note that the instructions of this manual do not substitute the technical characteristics engraved in the characteristics plate fixed on the equipment.

Read carefully the safety instructions!

  • Ensure sufficient ventilation in the room where the Canopy is being used at the same time as gas/other fuels burning equipment.
  • The installation and maintenance interventions must comply with the regional and national norms in Effect.
  • While installing the equipment make sure the weight is distributed evenly by every fixing point. Check the fixing area to make sure there is no risk of detachment.
  • Before using the equipment check for visible eventual damage. Never use damaged equipment!
  • To prevent the risk of damaging the equipment, verify that the power supply voltage and frequency comply with the specifications indicated in the characteristics plate.
  • This equipment is supplied with an equipotential connecting terminal, in the upper part, which must be properly connected with the earthing circuit by a certified technician.
  • This equipment is part of an exhaust system, which is complemented by a ventilation motor and an element of command to which will be connected the light bulb. Other installation methods are not foreseen.
  • Only properly qualified and certified technicians may conduct the installation and maintenance of the equipment. The manufacturer is not responsible for damage resulting from maintenance and other interventions conducted by unqualified technicians.
  • Do not make fire under the Canopy.
  • Always keep the equipment clean. Clean according to the recommendations supplied in this manual. Fire Hazard!
  • Risk of Burn Injuries! Do not open the oil drainage valve while the equipment is still hot.

Purpose of Use
The Inclined and Rectangular Canopies were conceived to collect the vapors resulting from cooking. The manufacturer does not advise any other use, noncompliance of this may compromise the safety of the equipment and the user. The Canopies are meant for commercial use. Do not use the equipment outside.

User Requirements
The equipment must be maintained out of reach of children and must be supervised in order to assure they do not play with the equipment.

Recycling
Packaging material: Before first use remove all plastic protections from the equipment. All packaging and protection materials are recyclable.

Verify the safe elimination of all plastic packaging. Maintain all packaging materials out of reach of children. Choking Hazard!

The electric and electronic equipment contain materials that, when wrongly used, may danger human health and the environment. Do not deposit any part or component of the equipment in domestic waste containers. Deposit them in industrial collecting centers, and contact your supplier or local authorities for advice.

General Characteristics

  • Stainless Steel Construction;
  • Stainless Steel Filters 400x400x20 for the 700 depth.
  • Stainless Steel Filters 400x500x20 for the 900/1100/1400 depths.
  • Oil Extraction Valve;
  • With LED lighting;
  • Without motor;

Model| Nº of Filter s| Lighting| Net Weight (Kg)| Gross Weight (Kg)| Packaging Dimensions

LxPxA (mm)

---|---|---|---|---|---
Número| Max Power

(LED tube )

| Hotte Inclinada / Retangular| Hotte Inclinada / Retangular
800x700x450| 1| 1×600| 1x8W| 26 / –| 35 / –| 870x530x850
1000x700x450| 2| 1×600| 1x8W| 29 / –| 39 / –| 1070x530x850
1200x700x450| 2| 1×600| 1x8W| 32 / –| 43 / –| 1270x530x850
1400x700x450| 3| 1×600| 1x8W| 38 / –| 50 / –| 1470x530x850
1600x700x450| 3| 1×1200| 1x16W| 41.5 / –| 55.5 / –| 1670x530x850
1800x700x450| 3| 1×1500| 1x24W| 44 / –| 59 / –| 1870x530x850
2000x700x450| 3| 1×1500| 1x24W| 47 / –| 63 / –| 2070x530x850
2200x700x450| 4| 1×1500| 1x24W| 53 / –| 69 / –| 2270x530x850
2400x700x450| 4| 2×600| 2x8W| 54 / –| 72 / –| 2470x530x850
2600x700x450| 4| 2×600| 2x8W| 57 / –| 76 / –| 2670x530x850
2800x700x450| 5| 2×600| 2x8W| 61,5 / –| 81,5 / –| 2870x530x850
3000x700x450| 6| 2×1200| 2x16W| 68 / –| 89 / –| 3070x530x850
 |  |  |  |  |  |
800x900x450| 1| 1×600| 1x8W| 30,5 / 35| 40,5 / 45| 870x530x1050
1000x900x450| 2| 1×600| 1x8W| 34 / 40| 45 / 51| 1070x530x1050
1200x900x450| 2| 1×600| 1x8W| 37,5 / 44| 49,5 / 56| 1270x530x1050
1400x900x450| 3| 1×600| 1x8W| 41,6 / 49| 54,6 / 62| 1470x530x1050
1600x900x450| 3| 1×1200| 1x16W| 46,5 / 51| 61,5 / 66| 1670x530x1050
1800x900x450| 3| 1×1500| 1x24W| 50 / 56| 66 / 72| 1870x530x1050
2000x900x450| 3| 1×1500| 1x24W| 53 / 60| 70 / 77| 2070x530x1050
2200x900x450| 4| 1×1500| 1x24W| 58 / 65| 76 / 83| 2270x530x1050
2400x900x450| 4| 2×600| 2x8W| 60,8 / 69| 79,8 / 88| 2470x530x1050
2600x900x450| 4| 2×600| 2x8W| 63,8 / 74| 83,8 / 94| 2670x530x1050
2800x900x450| 5| 2×600| 2x8W| 69,5 / 79| 91 / 100| 2870x530x1050
3000x900x450| 6| 2×1200| 2x16W| 77 / 84| 99 / 106| 3070x530x1050
 |  |  |  |  |  |
---|---|---|---|---|---|---
800x1100x450| 1| 1×600| 1x8W| 33 /41,5| 44 / 52,5| 870x530x1250
1000x1100x45| 2| 1×600| 1x8W| 37 / 45| 49 / 57| 1070x530x1250
1200x1100x45| 2| 1×600| 1x8W| 41,5 / 48| 54,5 / 61| 1270x530x1250
1400x1100x45| 3| 1×600| 1x8W| 46 / 53| 60 / 67| 1470x530x1250
1600x1100x45| 3| 1×1200| 1x16W| 51,5 / 58| 67,5 / 74| 1670x530x1250
1800x1100x45| 3| 1×1500| 1x24W| 56 / 63| 73 / 80| 1870x530x1250
2000x1100x45| 3| 1×1500| 1x24W| 60,5 / 67| 78,5 / 85| 2070x530x1250
2200x1100x45| 4| 1×1500| 1x24W| 64,5 / 73| 83,5 / 92| 2270x530x1250
2400x1100x45| 4| 2×600| 2x8W| 69 / 78| 89 / 98| 2470x530x1250
2600x1100x45| 4| 2×600| 2x8W| 73 / 82| 94 / 103| 2670x530x1250
2800x1100x45| 5| 2×600| 2x8W| 77,5 / 88| 100 / 110| 2870x530x1250
3000x1100x45| 6| 2×1200| 2x16W| 84 / 94| 107 / 117| 3070x530x1250
 |  |  |  |  |  |
1000x1400x450| 2| 1×600| 1x8W| – / 50| – / 63| 1070x530x1550
1200x1400x450| 2| 1×600| 1x8W| – / 54| – / 68| 1270x530x1550
1400x1400x450| 3| 1×600| 1x8W| – / 60| – / 75| 1470x530x1550
1600x1400x450| 3| 1×1200| 1x16W| – / 64| – / 81| 1670x530x1550
1800x1400x450| 3| 1×1500| 1x24W| – / 71,5| – / 89,5| 1870x530x1550
2000x1400x450| 3| 1×1500| 1x24W| – / 76,5| – / 95,5| 2070x530x1550
2200x1400x450| 4| 1×1500| 1x24W| – / 82| – / 102| 2270x530x1550
2400x1400x450| 4| 2×600| 2x8W| – / 86| – / 107| 2470x530x1550
2600x1400x450| 4| 2×600| 2x8W| – / 92| – / 114| 2670x530x1550
2800x1400x450| 5| 2×600| 2x8W| – / 97| – / 120| 2870x530x1550
3000x1400x450| 6| 2×1200| 2x16W| – / 104,8| – / 128,8| 3070x530x1550

Exploded View

PARRY-Modular-Extraction-Canopies-FIG-1

Letra Nome
A Welded Canopy structure (according to the model)
B Top Mid Cover 700/900/1100/1400
C Left Side Cover 700/900/1100/1400 (according to the model)
D Right Side Cover 700/900/1100/1400 (according to the model)
E Brass Bushing Ø25X9.5
F Small Sphere Tap F/F ½
G Filter Partition
H Filter for Canopy 400x400x20

Filter for Canopy 400x500x20
I| Wire Hole Ø 14mm
J| Sealed Lighting 600/1200/1500 With LAMP
K| One Hole Screw Ph 4,8x32mm + Screw Protection
L| Hexagon Nut M6 inox
M| Top Side Cover

Installation

Assembly Instructions:

  • Remove the equipment from the wood structure and, after that, the stainless-steel protection film carefully to avoid scratching the surface;

  • Remove the filters and the partitions as indicated by picture 2 (pull the filter immobilizer to release);

  • Move the Canopy with the aid of a fork lifter, insert the forks under the pallet and move, making sure the cargo is well balanced;

  • Do not pull or push the equipment to avoid damage or the risk of falling on the ground;
    Canopies made from more than one element. The Inclined and Rectangular Canopies allow for modular assembly with other Canopies from the same model!

  • Remove the side cover from the side in which is intended to make the union. See picture 3;

  • Place both modules side by side, making sure the screw holes are aligned and tighten the screws supplied with the union kit. See picture 4; PARRY-Modular-Extraction-Canopies-FIG-4

  • In the end place the bits in the union area of the Canopy. See picture 5;

  • Place the Canopy over the stove for which is meant. Have in attention that the external dimensions of the Canopy must exceed the dimensions of the stove by a minimum of 200mm.

  • The height of the lower part of the Canopy to the floor must be between 1850 and 2000 mm; the distance between the heating area and the lower part of the Canopy must be between 800 to 1000 mm.

  • The supply and exhaust of air must bem ade through conducts destined exclusively to the Canopy and must comply with applicable norms.

  • Mark the horizontal lines in the Wall and drill with the power drill to apply the bushings (not supplied);

  • Fix the Canopy temporarily and mark the vertical lines in the wall and drill;

  • Fix the equipment so that it does not detach from the wall;PARRY-Modular-Extraction-Canopies-FIG-6PARRY-Modular-Extraction-Canopies-FIG-7

Optional
Recommended to 1100 Depths

  • Tighten the metallic bushings with the hook to the ceiling;
  • Tighten the hooks with nuts in the upper corners of the Canopy, on the side opposing the wall;
  • Lift the Canopy to the desired height and suspend it by attaching the hooks previously applied;
  • Adjust by screwing or unscrewing the nuts of the hooks applied in the front of the Canopy.PARRY-Modular-Extraction-Canopies-FIG-8
Electrical Connection

Verify that the information indicated in the characteristics plate of the equipment matches the voltage and frequency of the power supply. PARRY-
Modular-Extraction-Canopies-FIG-9

Connect the equipment to a command device with an earthing circuit! Follow the norms in Effect in the country in which the installation occurs.

In the upper part of the equipment exists a connection terminal with the Symbol that allows for the equipotential connection between several devices.

Lighting Connection Diagram:

Maintenance

Cleaning:

  Control Frequency Preparation Execution



Mettalic Structure

| ****



Visual

| ****



Depending on Use

|  | Clean with a soft damp cloth, soaked in an alkaline detergent.

In case of heavy soiling, or encrustation, use a wood or plastic scraper.

Do not direct water jets to the Canopy!

Grease Filter| ****

Visual

| ****

1x per Week

| Remove the filters from the Canopy| Clean with hot water oro n the washing machine with an alkaline detergent.


Grease Drainage

| ****


Regular

| ****


1x per Week

| Open the drainage valve beneath the exhaust| Drain all the grease with the aid of a container.

Do not execute this operation while the equipment is hot!

Replacement Parts

 | ****

Identification

| ****

Substitution

---|---|---


Filter

| ****

400×400; 400×500

| ****

Remove the filter and substitute it for the new one.




Lighting

| ****

Consult the characteristics plate to identify maximum power;

Confirm light dimensions on the light socket;

| •          Release the stainless steel clips along the lighting socket. Turn the LED tube 90º and pull it

•          down. Make sure the light complies with the connection diagram.

•          Substitute the LED tube and replace the protection cover.

Attention! Make sure the power supply is disconnected before executing the operation.

Warranty

  • The equipment is warranted for a period of 12 months, from the date of purchase.
  • The warranty is valid for manufacturing defects, be it of materials or the manufacturing process.
  • Every time an anomaly is identified on the equipment, it must be returned promptly, along with the purchasing document or invoice.
  • When the warranty is applied, the damaged parts will be replaced or repaired, according to the manufacturer’s decision. In case of substitution, the damaged parts must be returned to the manufacturer.
  • The warranty excludes all defects and malfunctioning resulting from deficient installation or misuse of the equipment.
  • The equipment will lose warranty when a modification or alteration made by the user is identified.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals