ECOLAB BF16 Multi Booster Instruction Manual

June 4, 2024
ECOLAB

Multi Booster
BF16, BF24, BF32, BF40, BF48,
BF16T, BF24T, BF32T, BF40T, BF48T.
Instruction Manual
ECOLAB BF16 Multi Booster -ECOLAB BF16 Multi
Booster - 01

Description

The Booster in the Chameleon
Plus range is a completely functioning pumping station that supplies pressurized water to connected satellite hygiene stations.
Therefore the Booster must be supplied with water in sufficient quantity and power according to specifications.
The station is then ready for hygiene duties.
The Booster is fitted with a frequency-controlled pump which ensures a constant working pressure independent of usage pattern.

A typical Floor Booster installation is shown in fig. 2

  • Booster (1)
  • Satellite (2)

ECOLAB BF16 Multi Booster - Booster installationECOLAB BF16 Multi Booster - 02110002115

1.7 Multi Booster BF16 – BF24

1. Water inlet
2. Manifold inlet
3. Trigger sensor, flow sensor
4. Pump
5. Manifold outlet
6. Outlet pipe
7. Inverter box
8. Filter box
9. Electrical connection box
10. Floor bracket
11. Inlet ball valve
12. Outlet ball valve| 13. Operation panel
14. Strainer
15. Non-Return Valve
16. Pressure sensor
17. Display
18. Navigation buttons
19. Label
20. Name Label
21. • O Pushbutton.Stop
22. • I Pushbutton.Start
23. • Δ Lamp. Alight by error
24. Pressure sensor
---|---

ECOLAB BF16 Multi Booster - 04

1.3 Advanced Booster BF32 – BF40 – BF48

1. Water inlet
2. Manifold inlet
3. Trigger sensor, flow sensor
4. Pump
5. Manifold outlet
6. Outlet pipe
7. Inverter box
8. Filter box
9. Electrical connection box
10. Floor bracket
11. Inlet ball valve
12. Outlet ball valve
13. Operation panel| 14. Strainer
15. Non-Return Valve
16. Pressure sensor
17. Display
18. Navigation buttons
19. Label
20. Name Label
21. • O Pushbutton.Stop
22. • I Pushbutton.Start
23. • Δ Lamp. Alight by error
24. Nonreturn valve for by-pass
25. By-pass
26. Pressure sensor
---|---

ECOLAB BF16 Multi Booster - 03

1.3 Operating Diagrams acc. ISO14617 Multi Booster BF16 – BF24 – BF32 – BF40 – BF48

B. Ball valve.
F.  Filter
FST. Flow switch.
C. Check valve.
PE. Pressure sensor.
TE. Temperature sensor.
CP. Centrifugal pump.
D. Outlet.
PU. Pump unit.
W. Water inlet.
SN : Socket no.

Maintenance

The Booster unit is maintenance-free. However, we recommend cleaning the booster unit in connection with the occasional cleaning of the other equipment in the area.
The filter must be cleaned at convenient intervals (approx. every 1-3 months) depending on the number of impurities in the water.

2.1 Filter

  1. Press “0” on the control panel to stop the Booster.

  2. Interrupt the master switch (Fig. 1).

  3. Close the water inlet.

  4. Open a tap to release the system of pressure.

  5. Remove the filter (A, Fig. 2) and place it in a descaling solution.
    Note: MB systems are not delivered with a factory-mounted filter. In case a filter is mounted in an MB system, the
    descaling procedure is exactly the same until the scale is dissolved.

  6. Rinse the cleaned filter thoroughly and remount.

  7. Min filter mesh size 800µ -> 1500μ.

2.2 Before a longer production stop
If long production stops are planned (more than 6 months) and the pump is drained, it is recommended that the pump is secured as follows:

  1. Remove the coupling safety guard.
  2. Spray a couple of drops of silicone oil onto the axle between the top section and the coupling.

Carefully follow the instructions given in the manual provided by the pump supplier.

Start

3.1 New system
In order to ensure a problem-free start-up of a new system, the pipe system must be flushed and bled.

Bleeding the pipe system

  1. Turn on the water supply to rinse and bleed the entire system. If satellites are installed open the tap furthest away until no air or dirt comes out.
    Then rinse and bleed the next tap and continue until the tap closest to you has been rinsed and bled.

  2. Mount satellites, if any
    Bleeding the pump

  3. Press “0” on the control panel to stop the Booster.

  4. Loosen the relief plug (A, Fig34) 1-2 revolutions until water and air begin to flow out.
    Note. Never loosen the relief plug while the pump is running as this may damage the packing and cause personal injury.

  5. Tighten the relief plug again

  6. Start the pump so that all re- remaining air pockets are forced up to the top of the pump.ECOLAB BF16 Multi Booster - pockets are forced

  7. Stop the pump.

  8. Loosen the relief plug 1-2 revolutions again and bleed the system until only water flows out.

  9. Tighten the relief plug once more.

The Booster is now ready for operation. Press “I” on the control panel. (see fig. 4).

Daily operation

4.1 Start

  1. Check that water supplies for the system are open.
  2. Press “I” on the control board in order to start up the unit.

4.2 Stop

  1. Press “0” on the control panel to stop.
  2. Turn off the water supply.
  3. Switch off the air supply.

Note. Due to the following, it is very important always to switch off both water and air supply after use:

  • If the air supply is open when the main station or satellites are not in use, air might leak into the water line. If this happens, the system must be bled once more.
  • The water separator, which is a part of the air regulator, is only to be emptied when the air supply is closed.
    After a long time production stop (holidays etc) it might be necessary to bleed the piping system and the booster unit again.

Service

Service may only be carried out by authorized and qualified personnel.
Warning: The system must only be serviced when there is no voltage or pressure on the system.

  1. Turn off the main switch at the control box (Fig. 1)
  2.  Open a water outlet to depressurize the system.

5.1 Components
5.1.1 Pump/motor
Pump/motor are maintenance-free, see section 2.2
5.1.2 Control system
Maintenance free
If defective: Call service technician
5.1.3 Flow Switch
Maintenance-free.
If defective, replace the flow switch.
The orientation of the flow switch has to be done in such a way that the plug/cable end of the switch is pointing opposite the flow direction

5.1.3.1 Adjustment of flow switch
When the flow switch is replaced/installed it has to be adjusted.

  1. Press “1” on the control panel to turn on the machine.
  2. Turn the “rinse/foam” handle on a satellite to the foam position.
  3. Activate the spray handle on the outlet hose of the satellite so water runs out.
  4. Check that the flow switch is turned the correct way (the wire must be opposite the flow direction) (see picture).
  5. Remove the white plug/screw before adjusting (see picture).
  6. Adjust the flow to one green diode lights up (see picture).
  7. Close the spray handle again and check that the red diode lights up.
  8. Remount the white plug/screw.
    The flow switch is now adjusted.

ECOLAB BF16 Multi Booster - switch is now adjusted

5.1.4 Non-return valve / inlet side
Maintenance – free.
If defective, replace the non-return valve.
5.2 Recycling/scrapping
Recycle the wrapping and scrap the machine according to recommendations from the local authorities.

Troubleshooting

6.1 The unit does not start

ECOLAB BF16 Multi Booster - does not start

6.2 The “Δ”- lamp on the control panel is on

ECOLAB BF16 Multi Booster - amp on the control

6.3 If the inlet pressure is low or unstable

ECOLAB BF16 Multi Booster - ow or unstable

Recommended spare parts

The recommended spare parts are marked with * in the spare part manual.

Specifications

Technical Data Multi Booster.
BF16 BF24
Max. Outlet pressure. bar 25*
Consumption during rinsing. L/min 440
Consumption during foaming. L/min 160
Min. supply pressure. bar 2
Max. supply pressure. bar 8
Min. water supply. L/min 500
Max. water temp. °C 70
Pipe dimension inlet Ø inch 2 1/2″
Pipe dimension outlet Ø inch 2 1/2″
Electricity
Supply voltage V 3/PE 400 V ±10%
Frequency Hz 50±2
Motor load (kW) kW 22
Installation to EN 60204-1
Nominal current A 55
Fuse A 63
L1, L2, L3, PE mm2 2.5
General
Sound level ISO 11202 dB 85 dB
Dimensions mm 1112x530x1043
2822 1268 x 665 x 3248
Weight (kg) ca kg 190

Note:

  • Pump pressure 20 bar + inlet pressure max. 25 bar

Electric diagram

ECOLAB BF16 Multi Booster - 1

No: 110002302 Desc: Electrical connections MB
Version/Revision A Product no:
Initials: Date: Blytaekkervej 2 DK-9000 Aalborg

+45 72 18 20 00 www.nilfiskfood.com
Drawn by:| san| 21-Nov-11
Sheet size:| A4
Sheet no:| 1 of 1

ECOLAB BF16 Multi Booster -2

No: 110002310 Desc: Electrical connections MB
Version/Revision A Product no:
Initials: Date: Blytaekkervej 2 DK-9000 Aalborg

+45 72 18 20 00
www.nilfiskfood.com
Drawn by:| san| 21-Nov-11
Sheet size:| A4
Sheet no:| 1 of 1

ECOLAB BF16 Multi Booster - 3

No: 110002309 Desc: Electrical connections MB
Version/Revision A Product no:
Initials: Date: Blytaekkervej 2 DK-9000 Aalborg

+45 72 18 20 00
www.nilfiskfood.com
Drawn by:| san| 21-Nov-11
Sheet size:| A4
Sheet no:| 1 of 1

Pump curve

Pump curve BF16-BF48

ECOLAB BF16 Multi Booster - 4

Declaration of Conformity

BF16, BF24, BF32, BF40, BF48

Declaration of Conformity
We Nilfisk FOOD, declare under our sole responsibility that the products BF16+, BF24+, BF32+, BF40+, BF48+, to which this declaration relates, are in conformity with these Council directives on the approximation of the laws of the EC member state:
Function: Pumping Station
Model/Type: BF16-2+, BF24-3+, BF32-4+, BF40-5+, BF48-6+.
Serial number: All
Machinery Directive (2006/42/EC:2006-05-17).
Standard used: EN 60335-2-41/A2:2010
EMC Directive (2004/108/EC:2004-12-15).
Standard used: EN 55014-1/A1:2009 and EN 55014-2/A2:2008
Standard used: EN 61000-3-2/A2:2009 and EN 61000-3-3:2008

Technical file responsible:
Flemming Asp
Nilfisk FOOD
Blytaekkervej 2
9000 Aalborg, Denmark

ECOLAB BF16 Multi Booster - 5

Recommended spare parts

!| Pos./Ref.| No.| Description| BF16 / BF16T| BF24 / BF24T| BF32 / BF32T| BF40 / BF40T| BF48 / BF48T
---|---|---|---|---|---|---|---|---
| 1| | Page 4| | | | |
| 2| | Page 4| | | | |
| 3| | Page 8 / 9| | | | |
| 4| | Page 6 / 7| | | | |
| 5| 110000373| Pump| 2| 3| 4| 5| 6
| 6| | Page 5| | | | |
| 7| 110001855| Adjustable feet| 4| 6| 8| 10| 12
| 8| 110001144| Pressure Sensor| 2| 3| 4| 5| 6
| 9| 110001851| Flow-Switch| 1| 1| 1| 1| 1
| 10| 110001271| Nippel| 2| 3| 4| 5| 6
| 11| 110001842 (156704)| Screw kit for MB+| | | | |
| 12| 110001842 (156518)| Screw kit for MB+ (No tank control)| 1| 1| –| –| –
| 12| 110001842 (156502)| Screw kit for MB+ (No tank control)|

1

|

1

|

|

|

| 14| 110001842 (321700)| Screw kit for MB+| | | | |
| 15| | Page 6 / 7| | | | |
| 16| 110001863| Non-Return Valve| –| –| 1| 1| 1
| 17| 110001842 (156800)| Screw kit for MB+| | | | |
| 18| 110001842 (0602005)| Screw kit for MB+| | | | |
| 19| 110001842 (0602014)| Screw kit for MB+| | | | |
| 20| 110001842 (156702)| Screw kit for MB+| | | | |
| | | | | | | |
| 21| 110001842 (156504)| Screw kit for MB+ (No tank control)| 1| 1| –| –| –
---|---|---|---|---|---|---|---|---
| 12| 110001842 (0602057)| Screw kit for MB+| 1| 1| 1| 1| 1
| 13| 10001842 (156602)| Screw kit for MB+| 1| 1| 1| 1| 1
| 21| 110001842 (156607)| Screw kit for MB+| 1| 1| 1| 1| 1

ECOLAB BF16 Multi Booster - 6

!| | No.| Description| BF16 / BF16T| BF24 / BF24T| BF32 / BF32T| BF40 / BF40T| BF48 / BF48T
---|---|---|---|---|---|---|---|---
| 1| 110001846| Ball Tap| 2| 3| 4| 5| 6
| 2| 110002172| Strainer 800µ - > 1500μ | 2| 3| 4| 5| 6
| 3| 630900| Non Return| 2| 3| 4| 5| 6
| 4| 110001845| O-ring kit| | | | |
| 5| 110001250| Pin kit| | | | |
| 6| 110001850| Sensor| 2| 3| 4| 5| 6
| 7| 110001848| Inlet| 2| 3| 4| 5| 6
| 1| 110001846| Ball Tap| 2| 3| 4| 5| 6
---|---|---|---|---|---|---|---|---
| 2| 110001845| O-ring kit| | | | |
| 3| 110001250| Pin kit| | | | |
| 4| 110001856| Outlet pipe MB+| 2| 3| 4| 5| 6

ECOLAB BF16 Multi Booster - 7

!| Pos./Ref.| No.| Description| BF16| BF24| BF32| BF40| BF48
---|---|---|---|---|---|---|---|---
| 1| 110001841| Display complete| 1| 1| 1| 1| 1
| 2| 110001470| Operation panel| 1| 1| –| –| –
| 3| 110001854|  Label kit MB+| 1| 1| –| –| –
▲| 4| 110001842
(110000574)| Screw kit Adv+| | | | |
▲| 5| 110001842
(0602072)| Screw kit Adv+| | | | |
▲| 6| 110001842
(156517)| Screw kit Adv+| | | | |
▲| 7| 110001842
(110000235)| Screw kit Adv+| | | | |

ECOLAB BF16 Multi Booster - 8

!| | No.| Description| BF16 / BF16T| BF24 / BF24T| BF32 / BF32T| BF40 / BF40T| BF48 / BF48T
---|---|---|---|---|---|---|---|---
| 1| 110001857|  Switch| 1| –| –| –| –
| 1| 110001858|  Switch| | 1| –| –| –
| 2| 110001859| Automatic fuse| 2| 3| 4| 5| 6
| | 110001852| Electric cabinet complete BF16+| | | | |
| | 110001853| Electric cabinet complete BF24+| | | | |
| 1| 110001862| Switch| –| –| 1| 1| 1
| 2| 110001859| Automatic fuse| 2| 3| 4| 5| 6
| 3| 110001841| Display complete| 1| 1| 1| 1| 1
▲| 4| 110001842
(110000574)| Screw kit Adv+| | | | |
▲| 5| 110001842
(0600009)| Screw kit Adv+| | | | |
▲| 6| 110001842
(156302)| Screw kit Adv+| | | | |
| | 110001864| Electric cabinet complete BF32+| | | | |
| | 110001865| Electric cabinet complete BF40+| | | | |
| | 110001866| Electric cabinet complete BF48+| | | | |

ECOLAB BF16 Multi Booster - 9

!| Pos./Ref.| No.| Description| BF16T| BF24T| BF32T| BF40T| BF48T
---|---|---|---|---|---|---|---|---
| 1| 110001857| Switch| 1| –| –| –| –
| 1| 110001858| Switch| –| 1| –| –| –
| 1| 110001862| Switch| –| –| 1| 1| 1
| 2| 110001859| Automatic fuse| 2| 3| 4| 5| 6
| 3| 110001841| Display complete| 1| 1| 1| 1| 1
| 4| 110002194| Printed Circuit Board| 1| 1| 1| 1| 1
| 5| 110001842
(110000574)| Screw kit Adv+| | | | |
| 6| 110001842
(0600009)| Screw kit Adv+| | | | |
| 7| 110001842
(156302)| Screw kit Adv+| | | | |
▲| 8| 110001842
(15010200)| Screw kit Adv+| | | | |
▲| 9|  110001842
(110002187)|  Screw kit Adv+| | | | |
| | 110002210| Electric cabinet complete BF16T+| 1| | | |
| | 110002211| Electric cabinet complete BF24T+| 1| | | |
| | 110002212| Electric cabinet complete BF32T+| 1| | | |
| | 110002213| Electric cabinet complete BF40T+| 1| | | |
| | 110002214| Electric cabinet complete BF48T+| 1| | | |

ECOLAB BF16 Multi Booster - 10

!| Pos./Ref.| No.| Description| BF16 / BF16T| BF24 / BF24T| BF32 / BF32T| BF40 / BF40T| BF48 / BF48T
---|---|---|---|---|---|---|---|---
| 1| 110001131| Converter Box| 2| 3| 4| 5| 6
| 2| 110001527| Noise Filter| 2| 3| 4| 5| 6
▲| 3| 110001842 (0602104)| Screw kit Adv+| | | | |
| 4| 110001466| 11 kW Converter| 2| 3| 4| 5| 6
*| 5| 110001843| Controller board +| 2| 3| 4| 5| 6
| 6| 110001860| Mounting| 2| 3| 4| 5| 6
| 7| 110001381| Mounting| 4| 6| 8| 10| 12
| 8| 110001244| Fitting complete controller print +| 2| 3| 4| 5| 6
| 9| 110001849| Switch| 2| 3| 4| 5| 6
| 10| 110001467| EPM Module + Converterlabel| 2| 3| 4| 5| 6
| 11| 110001471| Mounting| 4| 6| 8| 10| 12
▲| 12| 110001842 (0602125)| Screw kit Adv+| | | | |
▲| 13| 110001842 (110001369)| Screw kit Adv+| | | | |
| 14| 110001127| Fuse| 2| 3| 4| 5| 6
| 15| 110001128| The cable between controller and inverter| 2| 3| 4| 5| 6
| 17| 110001861| Mounting| 2| 3| 4| 5| 6
| 18| 110001844| Converter Box| 2| 3| 4| 5| 6
| 19| 110000971| Sensor cable| 2| 3| 4| 5| 6
| 20| 110005373| Controller complete| 2| 3| 4| 5| 6
| 21| 0631176| Network cable| 1| 2| 3| 5| 6
| 22| 110003421| Flow switch cable| 1| 2| 3| 4| 5

© 2005 All rights reserved
Ecolab GmbH & Co. OHG
P.O. Box 13 04 06
D-40554 Düsseldorf
www.ecolab.com
Tel.: +49 211 98 93 203 – Fax: +49 211 98 93 223
Printed in Denmark

References