RAB LFLED 8LV Floodlight Instructions

June 10, 2024
RAB

RAB LFLED 8LV Floodlight

Product Information

The RAB Lighting LED floodlight is a high-quality, well-designed, and energy- efficient lighting fixture. It is designed to be mounted on a weatherproof junction box or a mighty post (sold separately). The fixture comes with a universal voltage driver that permits operation at 120V through 240V, 50 or 60 Hz. The fixture is equipped with a non-abrasive glass lens and an LED that does not require maintenance.

Product Usage Instructions

Wall Mounting
  1. Mount the fixture to a weatherproof junction box and cover plate (not provided) as shown in Fig. 1.
  2. Thread the fixture into the cover plate (sold separately).
  3. Connect wires as shown in the wiring diagram (Fig. 3).
  4. Attach the cover plate to the junction box (sold separately).
  5. Aim the floodlight in the desired direction and tighten the locknut and arm screw.
Ground Mounting
  1. Mount the fixture to a mighty post (RAB Cat# MP19) as shown in
    Fig. 2.

  2. Thread the fixture into the mighty post cap.

  3. Connect wires as shown in the wiring diagram (Fig. 3) and place
    inside the mighty post.

  4. Place the mighty post cap on the mighty post.

  5. Aim the floodlight in the desired direction and tighten the
    locknut and arm screw.

Wiring
  1. Connect the black fixture lead to the (+) LINE supply lead.
  2. Connect the white fixture lead to the (-) COMMON supply lead.
  3. Connect the ground wire from the fixture to the supply ground.
Cleaning & Maintenance

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean the glass lens with a non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.
Troubleshooting
  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Ensure that the fixture is grounded properly.
  3. Keep leaves and debris out of the hood.

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation, or maintenance.

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside. CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened fi rmly. Apply weatherproof silicone sealant around the edge of the wall cover plate or junction box. This is especially important with an uneven surface. Suitable for wet locations. Suitable for mounting within 1.2m (4ft) of the ground. Suitable for wet locations.

WALL MOUNTING

Mount to a weatherproof junction box and cover plate (not provided) as shown in Fig. 1. To ensure weatherproof seal, apply weatherproof silicone sealant around the edge of the wall cover plate or surface box. This is especially important with an uneven wall surface.

  1. Seal arm thread using Tefl on® tape or silicone sealant.
  2. Thread fixture into Cover Plate (sold separately).
  3. Connect wires as shown in the wiring diagram (Fig. 3).
  4. Attach Cover Plate to Junction Box (sold separately).
  5. Aim floodlight in the direction desired and tighten Locknut and Arm Screw.

GROUND MOUNTING

Mount to a Mighty Post (RAB Cat# MP19) as shown in Fig. 2.

  1. Thread fixture into Mighty Post Cap.
  2. Connect wires as shown in the wiring diagram (Fig. 3) and place inside the Mighty Post.
  3. Place Mighty Post Cap on the Mighty Post.
  4. Aim floodlight in the direction desired and tighten Locknut and Arm Screw.

WIRING

Universal voltage driver permits operation at 120V through 240V, 50 or 60 Hz.

  1. Connect the black fixture lead to the (+) LINE supply lead.
  2. Connect the white fixture lead to the (-) COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.

ACCESSORIES

Reflector door lens kit can be ordered separately:

  • LNSLFLED8 15° spot reflector, door, lens kit for LFLED8
  • LSLFLED8 20° spot reflector, door, lens kit for LFLED8

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean glass lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Keep leaves and debris out of hood.

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers
rablighting.com
Visit our website for product info

Tech Help Line
Call our experts: 888 722-1000

e-mail
Answered promptly – sales@rablighting.com

Free Lighting Layouts
Answered o © 2023 RAB LIGHTING Inc. nline or by request

RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals