SATCO S11920-CS LED T8 Tube Lamp Instruction Manual
- June 10, 2024
- SATCO
Table of Contents
SATCO S11920-CS LED T8 Tube Lamp
Product Features
- UL certified
- Full glass housing: No Aging, Yellowing, Bending.
Product Applications
Widely used in residential buildings, offices, shopping malls,
supermarkets, hospitals, assembly lines, warehouses, etc. for energy saving
illumination.
Installation Instructions
Please completely comply with these instructions and notes, to ensure that the
product is operated in a safe condition.
Safety Precautions
For your and others’ safety, please read the precaution carefully before installation:
- Product should be installed by qualified electrician.
- Switch off the power supply before commencing work, make sure correct connection before power on.
- Do not apply uncertified LED driver with the product.
- Not For Emergency Lighting.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1 )this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
Wiring Instruction
Electronic Ballast
Magnetic Ballast
WARNING
- Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
- Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders.
Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. DO NOT ALTER, RELOCATE, OR REMOVE WIRING, LAMPHOLDERS, POWER SUPPLY, OR ANY OTHER ELECTRICAL COMPONENT
THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A LUMINAIREWHERETHE SUITABILITY OFTHE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITIES HAVING JURISDICTION
The units covered by this report were intended to retrofit surface mount, Type IC or non-IC recessed mount Listed fluorescent luminaires that use maximum four tubular lamps, the minimum lamp compartment dimensions are tabulated below:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>