Autonics BR Series Cylindrical Photoelectric Sensors Instruction Manual
- June 10, 2024
- Autonics
Table of Contents
- BR Series Cylindrical Photoelectric Sensors
- Safety Considerations
- Cautions during Use
- Product Components
- Ordering Information
- Sold Separately
- Cautions during Installation
- Operation Timing Chart
- Connections
- Sensitivity Adjustment
- Dimensions
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Cylindrical Photoelectric Sensors
BR Series
INSTRUCTION MANUAL
TCD210057AC
BR Series Cylindrical Photoelectric Sensors
Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using
the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction
manual, other manuals and Au tonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for
product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.
Safety Considerations
- Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
- symbol indicates caution due to special circumstances in which hazards may occur.
Warning Failure to follow instructions may result in serious injury or death.
-
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g., nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in personal injury, economic loss or fire.
-
Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present.
Failure to follow this instruction may result in explosion or fire. -
Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire. -
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire. -
Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
Caution Failure to follow instructions may result in injury or product damage.
-
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage. -
Use a dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire.
Cautions during Use
- Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
- When connecting an inductive load such as DC relay or solenoid valve to the output, remove surge by using diodes or varactors.
- Use the product after 0.5 sec of the power input. When using a separate power supply for the sensor and load, supply power to the sensor first.
- 12-24 VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
- Wire as short as possible and keep it away from high voltage lines or power lines to prevent surge and inductive noise.
- When using switching mode power supply (SMPS), ground F.G. terminal and connect a condenser between 0V and F.G. terminal to remove noise.
- When using a sensor with a noise-generating equipment (e.g., switching regulator, inverter, and servo motor), ground F.G. terminal of the equipment.
- This unit may be used in the following environments.
– Indoors (in the environment condition rated in ‘Specifications’)
– Altitude max. 2,000 m
– Pollution degree 2
– Installation category II
Product Components
- Product
- M18 fixing nut × 2
- Washer (metal material model)
- Instruction manual
- Adjustment screwdriver
Ordering Information
This is only for reference, the actual product does not support all
combinations.
For selecting the specified model, follow the Autonics website.
-
Material
No mark: Metal
P: Plastic -
Connection
No mark: Cable type
C: Connector type -
Control output
No mark: NPN open collector output
P: PNP open collector output
Sold Separately
• Connector cable, connector connection cable
Cautions during Installation
-
Be sure to install this product by following the usage environment, location, and specified ratings. Consider the listed conditions below.
– Installation environment and background (reflected light)
– Sensing distance and sensing target
– Direction of target’s movement
– Feature data -
When installing multiple sensors closely, it may result in malfunction due to mutual interference.
-
For installation, tighten the screw with a torque of 14.7 N m (metal material model), 0.39 N m (plastic material model). In case of the connector type, tightening torque for connector is from 0.39 to 0.49 N m.
-
Do not impact with a hard object or bend the cable excessively. That could decrease the product’s water resistance.
-
Use this product after the test. Check whether the indicator works appropriately for the positions of the detectable object.
Reflective
Sensor – Sensing target:
Install to face each other (parallel with the sensing side of the unit)
Operation Timing Chart
Operation mode | Light ON | Dark ON |
---|---|---|
Received light | Received Interrupted | Received Interrupted |
Operation indicator (red) | ON OFF | ON OFF |
Transistor output | ON OFF | ON OFF |
- For preventing the malfunction, the transistor output maintains OFF state for 5 sec after power-on.
Connections
Cable type
Connector type
Operation mode selection
Be sure to connect the control wire when selecting the operation mode. Failure to this instruction may result in product damage.
Operation mode | Wiring |
---|---|
Dark ON | Connect the control wire (white) to +V (brown) |
Light ON | Connect the control wire (white) to 0 V (blue) |
Circuit
NPN open collector output | PNP open collector output |
---|
- OCP (over current protection), SCP (short circuit protection)
- If short-circuit the control output terminal or supply current over the rated specification, normal control signal is not output due to the protection circuit.
Sensitivity Adjustment
- Set the adjuster for stable Light ON area, minimizing the effect of the installation environment.
- Use the offered adjustment screwdriver. Do NOT turn with excessive force to prevent product damage.
- The steps below are based on Light ON mode.
STEP | Status | Description |
---|---|---|
Received | Turn the adjuster from MIN to MAX sensitivity and check the |
position (A) where the operation indicator activates under the light ON area.
02| Interrupted| | Turn the adjuster from (A) to MAX and check the position
(B) where the operation indicator activates under the light OFF area.
If the operation indicator does NOT activate at the MAX (maximum sensitivity):
MAX = (B).
03| –| | Set the adjuster at the mid position between (A) and (B) for optimal
sensitivity.
Dimensions
- Unit: mm, For the detailed drawings, follow the Au tonics website.
A | Lens | C | Sensitivity adjuster |
---|---|---|---|
B | Operation indicator (red) |
Metal material model
Plastic material model
M18 fixing nut | Washer |
---|
Specifications
Model | BR□200-DDTN-□-□ |
---|---|
Sensing type | Narrow beam reflective |
Sensing distance | 200 mm 01) |
Sensing target | Opaque materials, translucent materials |
Hysteresis | ≤ 20 % of sensing distance |
Response time | ≤ 1 ms |
Light source | Infrared |
Peak emission wavelength | 850 nm |
Sensitivity adjustment | YES (Adjuster) |
Operation mode | Light ON mode – Dark ON mode selectable (Control wire) |
Indicator | Operation indicator (red) |
Approval |
- Non-glossy white paper 100 × 100 mm
Unit weight (packaged)| Metal material model|
Plastic material model
---|---|---
Cable type| ≈ 120 g (≈ 160 g)| ≈ 100 g (≈ 140 g)
Connector type| ≈ 50 g (≈ 90 g)| ≈ 30 g (≈ 70 g)
Power supply| 12-24 VDC ±10 % (ripple P-P: ≤ 10 %)
---|---
Current consumption| ≤ 45 mA
Control output| NPN open collector output / PNP open collector output
model
Load voltage| ≤ 30 VDC
Load current| ≤ 200 mA
Residual voltage| NPN: ≤ 1 VDC , PNP: ≤ 2.5 VDC
Protection circuit| Reverse power protection circuit, output short
overcurrent protection circuit
Insulation resistance| ≥ 20 MΩ (500 VDC megger)
Noise immunity| ±240 VDC the square wave noise (pulse width: 1 ㎲) by
the noise simulator
Dielectric strength| 1,000 VAC 50/60 Hz for 1 min
Vibration| 1.5 mm double amplitude at frequency of 10 to 55 Hz (for 1
min) in each X, Y, Z direction for 2 hours
Shock| 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Ambient illuminance (receiver)| Sunlight: ≤ 11,000 lx,
incandescent lamp: ≤ 3,000 lx
Ambient temperature| -10 to 60 ℃, storage: -25 to 75 ℃ (no freezing
or condensation)
Ambient humidity| 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or
condensation)
Protection rating| IP66 (IEC standard)
Connection| Cable type / Connector type model
Cable spec.| Ø 5 mm, 4-wire, 2 m
Wire spec.| AWG22 (0.08 mm, 60-core), insulator outer diameter: Ø
1.25 mm
Connector| M12 4-pin plug type
Material| Case: Brass, Ni-plate (metal material model) or PA Black
(plastic material model), sensing part: PC lens
18, Ban song 513Beon-gil, Sundae, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>