Product Information

ATM Series
The ATM series is a time delay relay unit with various time ranges designed for use in machinery control, nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, and other applications where fail-safe devices are necessary.

Safety Considerations

  • A fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss.
  • Do not use the unit in places where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
  • Install on a device panel before use.
  • Do not connect, repair, or inspect the unit while connected to a power source.
  • Check connections before wiring.
  • Do not disassemble or modify the unit.
  • Use the unit within the rated specifications.
  • Use a dry cloth to clean the unit and do not use water or  organic solvent.
  • Keep the product away from metal chips, dust, and wire residue which flow into the unit.

Product Components

The product components include an output indicator (red), power indicator (green), time unit (sec/min/hour), and a dial for the time setting.

Product Operation Timing Chart

The operation timing chart shows the power on/off timing and the time limit for N.C. (normally closed) and N.O. (normally open) switches. The power indicator shows when the unit is turned on/off, and the output indicator shows the status of the control output.

Product Connections

Refer to the ‘specifications’ for checking the power supply and control output. The unit supports both IEC and NEMA marking.

Product Usage Instructions

  1. Install the unit on a device panel before use.
  2. Check connections before wiring.
  3. Use the unit within the rated specifications.
  4. Use a dry cloth to clean the unit and do not use water or organic solvent.
  5. Keep the product away from metal chips, dust, and wire residue  which flow into the unit.
  6. Set the time range according to your application needs using the dial for the time setting.
  7. Connect the power supply and control output according to the specifications.
  8. Turn on the power and the power indicator will show that the unit is turned on.
  9. When the time limit for N.C. or N.O. switches is reached, the  output indicator will show the status of the control output.

Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using. For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.

  • Keep this instruction manual in a place where you can find easily.
  • The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
  • Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • warning: symbol indicates caution due to special circumstances in which hazards may occur.

Warning: Failure to follow instructions may result in serious injury or death.

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in  personal injury, economic loss or fire.

  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present. Failure to follow this instruction may result in explosion or fire.

  3. Install on a device panel to use. Failure to follow this instruction may result in fire or electric shock.

  4. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in fire or electric shock.

  5. Check ‘Connections’ before wiring.
    Failure to follow this instruction may result in fire.

  6. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in fire or electric shock.

Caution: Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or product damage.

  2. Use a dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in fire or electric shock.

  3. Keep the product away from metal chip, dust, and wire residue which flow into the unit.
    Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.

  • The power supply should be insulated and limited voltage/current or Class2, SELV power supply device.

  • When supplying or turning off the power, use a switch or etc. to avoid chattering.

  • Install a power switch or circuit breaker in an easily accessible place for supplying or disconnecting the power..

  • In order to avoid leakage current flowing, connect resistance and condenser like below. Otherwise, it may cause malfunction.

  • After turning off the power, changing the time range, etc.

  • Keep away from high voltage lines or power lines to prevent inductive noise. In the case installing the power line and input signal line closely, use a line filter or varistor at the power line and shielded wire at the input signal line.
    Do not use near equipment which generates strong magnetic force or high- frequency noise.

  • This unit may be used in the following environments.

    • Indoors (in the environment condition rated in ‘Specifications’)
    • Altitude max. 2,000 m
    • Pollution degree 2
    • Installation category II

Ordering Information
This is only for reference, the actual product does not support all combinations. For selecting the specified model, follow the Autonics website.

Autonics-ATM4-610S-ATM-Series-W21-5-×-H-28-mm-Analog-Timers-
fig-2

Product Components

  • Product
  • Instruction manual

Dimensions

  • Unit: mm, For the detailed drawings, follow the Autonics website.
  • Mount the My socket (sold separately).Autonics-ATM4-610S-ATM-Series-W21-5-×-H-28-mm-Analog-Timers-fig-3

Pin arrangement

Unit Descriptions

Autonics-ATM4-610S-ATM-Series-W21-5-×-H-28-mm-Analog-Timers-
fig-5

Time Range

Model Unit Range
ATM4-1S ****

SEC

| 0.1 to 1
ATM4-5S| 0.5 to 5
ATM4-10S| 1 to 10
ATM4-30S| 3 to 30
ATM4-60S| 6 to 60
ATM4-3M| ****


MIN

| 0.3 to 3
ATM4-5M| 0.5 to 5
ATM4-10M| 1 to 10
ATM4-30M| 3 to 30
ATM4-60M| 6 to 60
ATM4-3H| HOUR| 0.3 to 3

Operation Timing Chart

  • t: setting time,
  • Rt : return time

Connections

Caution: Refer to the ‘specifications’ for checking the power supply and control output.
IEC marking: This type of connection is marked on the product

NEMA marking

Specifications

Model ATM4-2 ATM4-5 ATM4-6
Function Power ON Delay
Return time ≤ 100 ms
Time operation Power ON Start
Control output Relay
Contact type 4PDT (4c)
Contact capacity 250 VAC 3 A, 24 VDC 3 A resistive load

Error

| Repeat: ≤ ± 0.5% ± 10 ms SET: ≤ ± 10% ± 50 ms

Voltage: ≤ ± 0.5% ± 10 ms

Temp.: ≤ ± 2% ± 10 ms

Approval|
Unit weight (packaged)| ≈ 42 g (≈ 48 g)
Power supply| 24 VDC| 220 VAC 50 / 60 Hz| 110 VAC 50 / 60 Hz
---|---|---|---
Allowable

voltage range

| 21.6 – 26.4 VDC| 200 – 230 VAC 50 / 60 Hz| 100 – 120 VAC 50 / 60 Hz
Power consumption| ≈ 1.2 W| ≈ 3 VA| ≈ 3 VA
Insulation resistive| ≥ 100 MΩ (500 VDC megger)
Dielectric strength| 3,000 VAC at 50 / 60 Hz for 1 min
Noise immunity| ± 2 kV square-wave noise by noise simulator (pulse width 1 ㎲)
Vibration| 0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X,

Y, Z direction for 1 hour

Vibration (malfunction)| 0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X,

Y, Z direction for 10 min

Shock| 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (malfunction)| 100 m/s2 (≈ 10 G) In each X, Y, Z direction for 3 times
Relay life cycle| Mechanical: ≥ 10,000,000 operations Electrical: ≥ 200,000 operations
Ambient temperature| -10 to 50 ℃, storage: -25 to 65 ℃ (no freezing or condensation)
Ambient humidity| 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)