Milesight AM300 Series Indoor Ambience Monitoring Sensor User Guide

June 10, 2024
Milesight

Milesight AM300 Series Indoor Ambience Monitoring Sensor

AM300 Series Quick Start Guide

The AM300 Series is a sensor device that monitors indoor air quality. It comes with various features that allow users to easily set up and use the device.

Packing List

  • 1 x AM300 Series Sensor
  • 1 x Mounting Bracket
  • 1 x 3M Double-Sided Tape
  • 3 x Wall Mounting Kits
  • 1 x Fixing Screw
  • 4 x ER14505Li-SOC12 Batteries (AM307 & AM308)
  • 1 x Type-C Cable & Power Adapter (AM319)
  • 1 x Quick Start Guide
  • 1 x Warranty CardMilesight AM300 Series Indoor Ambience Monitoring Sensor-fig-2

Hardware Introduction

  • E-ink Screen
  • Light Sensor
  • PIR Sensor
  • NFC Area
  • Traffic Light Indicator
  • Power Button
  • Reset Button
  • Type-C Port
  • Battery CompartmentMilesight AM300 Series Indoor Ambience Monitoring Sensor-fig-3

Button & Traffic Light Indication

Milesight AM300 Series Indoor Ambience
Monitoring Sensor-fig-4

The following functions can be performed using the buttons on the device:

  • Power ON/OFF: Press and hold the power button for more than 3 seconds.
  • Switch Display Mode: Quick press the power button once.
  • Reset to Factory Default: Press and hold the reset button for more than 10 seconds.
  • Threshold Alarm: When one of the concentrations of air pollutants of CO,TVOC, PM2.5, PM10 or HCHO/O exceeds the threshold.

The traffic light indicator can be used to indicate the indoor air quality:

  • Green: You are having a healthy environment!
  • Yellow: When one of the concentrations of air pollutants of CO, TVOC, PM2.5, PM10 or HCHO/O exceeds the Polluted threshold.
  • Red: When one of the concentrations of air pollutants of CO,TVOC, PM2.5, PM10 or HCHO/O exceeds the Bad threshold.

Note:

  • If the buzzer is enabled, it will respond when one of the concentrations of air pollutants exceeds the Bad threshold.
  • AM319 supports Traffic Light as Blinking or Always On to indicate Polluted or Bad indoor ambiance, while AM307 and AM308 only support Blinking mode.

Power Supply

To power on the device, follow these steps:

  1. Release the screw at the back of the device and remove the rear cover.
  2. Install the batteries or Type-C cable to the device. If the device is powered via Type-C port, then left or right side should be made an opening to pass through the Type-C cable.Milesight AM300 Series Indoor Ambience Monitoring Sensor-fig-6
  3. Fix the cover back to device with the screw.Milesight AM300 Series Indoor Ambience Monitoring Sensor-fig-7

Note that AM307 and AM308 can be powered by ER14505 Li-SOCl2 batteries, and AM319 only supports Type-C power supply. Also, the battery should be removed from the device if not to be used for an extended period.

  • AM307 and AM308 can be powered by ER14505
  • Li-SOCl2 batteries, AM319 only support type-C power supply.
  • Type-C port can’t be used to charge the battery.
  • The battery should be removed from the device if not to be used for an extended period. Otherwise, the battery might leak and damage the device. Never leave a discharged battery in the battery compartment.

Emoticon Descriptions

Milesight AM300 Series Indoor Ambience Monitoring
Sensor-fig-5

Configuration Guide

The device can be configured using two methods:

  1. NFC: Attach the smartphone with NFC area to read/write the device using Milesight ToolBox App. If a smartphone is used for configuration for the first time, it’s necessary to enter the password.
  2. USB: Connect the device to a PC using a Type-C USB cable and use ToolBox Software to configure it.

For more information on installation and usage, please refer to the user manual.

Method 1: Configured by NFC

Preparation:

  • Smartphone (NFC supported)
  • Milesight ToolBox App: App can be downloaded on Google Play or App Store.

Steps:
Open “Milesight ToolBox” App and attach the smartphone with NFC area to read/write the device until App shows a successful prompt. If a smartphone is used for configuration for the first time, it’s necessary to enter the password.
(Default password: 123456)

Besides, it can be configured by dedicated NFC reader provided by Milesight loT.

Method 2:Configured by USB

Preparation:

  • Type-C USB cable
  • PC (Windows 10 is recommended)
  • ToolBox Software: it can be downloaded on the Milesight loT website.

Steps:
Connect the device to the computer via type-C port and open the ToolBox, select the serial port as USB port and type as “General”, then type the password to log in ToolBox and configure the device. (Default loggin password:123456)

Installation

Step 1: Fix the mounting bracket via one of the following methods:
Fixed by 3M Tape: Paste 3M double-sided tape to the back of mounting bracket, then tear the other side and place the bracket on a flat surface.
Wall Mounting: Fix the wall plugs into the wall, then fix the mounting bracket to the wall plugs with screws.
86Box Mounting: Fix the bracket to the 86box with 2 screws.

Step 2: Put the device on the mounting bracket, then fix the bottom of the device to the bracket with a fixing screw.Milesight AM300 Series Indoor
Ambience Monitoring Sensor-fig-12

FCC Statement

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Reorient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
www.milesight-iot.com

All software & files can be downloaded from https://www.milesight-iot.com /documents-download/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals