GLOBAL INDUSTRIAL 694562PBK Mobile Powered Computer Workstation User Manual
- June 10, 2024
- GLOBAL INDUSTRIAL
Table of Contents
User’s manual
Customer Service
US: 1-800-645-2986
Powered Mobile Computer Cabinet
Model(s): 694562PBK, 694562PBL, 694562PGY
694562PBK Mobile Powered Computer Workstation
REF| QTY| DESCRIPTION| REF| QTY| DESCRIPTION|
---|---|---|---|---|---|---
1| 1| BACK PANEL| H1| 8| M6X20mm ROUND
PHILLIP HEAD SCREW|
2| 1| LEFT SIDE PANEL| H2| 8| 6.5mm PLATE
WASHER|
3| 1| RIGHT SIDE PANEL| H3| 8| 6.5mm SPLIT
WASHER|
4| 1| TOP| H4| 2| HINGE
PIN|
5| 1| BASE| HS| 4| PLASTIC HINGE
CAP|
6| 1| FRONT FRAME| H6| 4| SHELF
CLIP|
7| 1| DOOR| H7| 2| SHEET METAL
SCREW|
8| 1| MIDDLE SHELF| H8| 2| KEY|
9| 1| ADJUSTABLE SHELF| H9| 2| OUTLET HOLE COVER
RING|
1 0| 1| CONNECTING PLATE| H10| 16| HEXAGON SCREW M10X25
mm|
11| 1| KEYBOARD TRAY| H11| 16| 10.5mm PLATE WASHER|
12| 1| 40 AH/500 W
PORTABLE POWER SYSTEM| H 1 2| 1 6| 10.5mm SPLIT WASHER|
| | | H13| 4| WHEEL|
| | | H 1 4| 1 SET| GUIDE RAIL|
40 AH/ 500W Pure Sine Wave
Portable Power Supply
Model: 436980
Converts the power of a DC 12V Lead-Acid Battery to AC 100-120V/60Hz
AC Voltage through an inverter to supply power to electric hardware.
This product has: under-voltage protection, overload protection, power display
and low voltage prompt
Product Composition
This product is composed of:
Main housing, Lead-acid battery, Charger,
Inverter, Relay, American Standard power strip, Power display, 12V DC power
supply, Heat dissipation fan
Product Parameters
Overall Size: 14″ x 12″ x 11″
Weight: Net: 46.5 lbs, Gross: 55 Ibs
Charging Input Voltage: 100-240VAC 50/60 Hz, 9.9A (max)
Load Output Parameters AC: 100-120V, 60Hz, 1000W
USB Output Parameters DC: 5V 2.1A
Charging time: 5hrs Full Charge
Operating Ambient Temperature: 32-104 ‘F
Power Display: 7 Bar Voltage and Percentage Display
This product charges the internal lead-acid battery through the charger. After the battery is fully charged, the battery voltage (DC 12V) is converted to 100-120V AC through the inverter for output. When the battery is fully charged, the charger will automatically protect the battery by disconnecting the charger plug, and the relay coil to the inverter is closed. At this time, the inverter can be used with a load. During the use of this product, the power display shows the corresponding voltage prompt according to the power consumption proportion of the battery voltage. When the voltage of the lead- acid battery is lower than 10%, a buzzer will start an alarm. When charging, the charger must be connected to an external power supply to charge the lead- acid battery. During charging, the relay disconnects the lead-acid battery from the inverter. The inverter cannot supply a load while charging. This product has over-load and over-current protection, as well as under-voltage protection and charging surge protection.
Warnings:
-
The voltage of each electrical appliance is different. Before using any device with this power supply, check whether the rated voltage range of the product is compatible with the output of the power supply. Mis-matched voltage can cause damage and injury to the device, the power
supply, and the user. -
If the battery is discharged to the cut-off voltage, further discharge is called over-discharge.
Over-discharging can easily cause severe loss of battery power and shortens battery life. Avoid over-discharging the batter when in use by charging it once the cut-off voltage is reached. -
Keep the battery away from fire, high temperatures, humid or rainy environments during use and storage.
-
Do not disassemble the power supply. This item has a built-in high voltage power supply.
-
Do not throw this power supply in general trash at the end of its life. Please recycle this item according to local laws and regulations.
-
The procruct’s casing should be effectively and firmly grounded before use.
-
Disconnect charging power cord before removing the case lid to remove or replace the battery.
-
Disconnect the charging power cord before plugging any devices into the power supply.
Portable Power Supply
Product Features Descriptions
First Time Set-up Instructions
Step 1:
Open Casing by loosening
Hex Screws using included
Allen Key| | Step 2:
Remove power cabinet cover.|
---|---|---|---
Step 3:
Identify the battery wire
terminals. Note that RED
terminals correspond to the
Positive(+) battery terminal.| | Step 4:
Insert bolt through Red(+)
wire terminal. Place the flat
washer, lock washer, then
bolt onto the battery terminal
nut and tighten securely with
wrenches.|
Step 5:
Insert bolt through Black
(-)terminal. Be cautious of
sparks; it is normal to spark
for a first time, connection.
Place the flat washer, lock
washer, then bolt into the
nut and tighten securely with
wrenches.| | Step 6:
Place battery cover on and
securely tighten Hex Screws.|
Charging Instructions
Insert one end of the input line into the charging socket of the housing, and
the other end into an external energy source, including wall outlets. Check
that the input voltage is within 100-240VAC 50/60Hz .| Product Operation
Steps
1. Connect the device to the Power Strip on the housing.
2. Turn on the power switch located on the front of the housing and the red
button on the power strip IN THAT ORDER.
Maintenance Information
- Each time the unit is fully charged, unplug and let the unit cool for approximately 10 min.
- Charge fully before use, especially for first time use.
- Periodically clean dust and dirt from heat dissipation louvers.
- Keep the housing dry and clean to protect battery from discharging on its own.
- Do not store the battery uncharged. If it is to be stored for a long time, it should be fully charged, placed in a cool and dry place, and recharged regularly.
- At low temperatures, there can be issues of battery powerloss caused by poor charging acceptance and insufficient charging. Thermal insulation and anti-freezing measures must be taken at low temperature, especially while charging. The device should be kept in a warm environment to prevent irreversible sulfation.
- Do NOT expose the product to moisture or water- Do not wash product.