legrand 0 670 99 Switch Sensor 3-Wire 2000 W User Manual
- June 4, 2024
- Legrand
Table of Contents
legrand 0 670 99 Switch Sensor 3-Wire 2000 W
Switch sensor 3-wire – 2000 W
USE
Switch sensor with neutral, infrared detection (PIR). Allows a light source to be controlled automatically through the detec-tion of any presence in the surveillance zone.Presence sensor with 120° detection angle. For flush- mounting, back box to be min. 40 mm deep. To be equipped with plate.
RANGE
Description | Colour | Cat. Nos |
---|---|---|
Switch sensor 2000 W Céliane 3-wire with neutral |
–
|
0 670 99
Switch sensor 2000 W Mosaic 3-wire with neutral| White Alu
Matt Black
| 0 784 54
0 792 58
0 791 58L
| White| 5 740 47
Switch sensor 2000 W Arteor| Magnesium| 5 740 97
3-wire with neutral| Soft alu| 5 741 40
Champagne| 5 741 41
DIMENSIONS (mm)
PRESENTATION
CONNECTION
- Number of terminals: 3
- Type of terminals: automatic
- Terminal capacity: 2 x 2.5 mm2 Stripping length: 8 mm
- Compatible with flexible or rigid cables
TECHNICAL CHARACTERISTICS
Mechanical characteristics Protection against impact:
IK 04 Protection against solid bodies and liquids:
- IP 20 mechanism alone
- IP 40 mounted product with rocker and plate
Material characteristics
Colour: – White RAL 9003
- Aluminium
- Magnesium
- Soft alu
- Champagne
- Matt Black satin RAL 9017
-
* Material: – Plate: ABS
-
- Halogen-free
- UV-resistant
Self-extinguishing: 850°C/30 s for insulating components holding live parts in
place. 650°C/30 s for other insulating components.
Electrical characteristics
- Voltage: 100-240 V~
- Frequency: 50/60 Hz
- Standby consumption: 0.2 W
- Output via normally open contact connected to the phase Power:
- Halogen bulb
- ELV halogen bulb with separate ferromagnetic ballast
- ELV halogen bulb with separate electronic ballast
- Fluorescent tube with separate ferromagnetic ballast
- ELV fluorescent tube with separate electronic ballast
- Compact fluorescent bulb with built-in electronic ballast
- LED bulb with built-in electronic ballast
- Contactor
Important: Take account of transformer losses when calculating power.
Transformers must be loaded at more than 60 % of their power.
Note: Possibility to mix any type of load on the same circuit.
Climate characteristics
- Usage temperature: -5°C to +35°C
- Storage temperature: -10°C to +70°C
OPERATION
More than one sensor and more than one load Auto ON/OFF mode:
The load will be switched on and off automatically.
Option:
It is possible to control the sensor by infrared remote control using: Cat.
Nos. 0 882 00/01/20/31/32/33. Synchronising the products is done in two
stage:
- one long press (>1s) all the sensors (S) switch to the ON state
- one short press all the sensors (S) switch to the OFF state
Several sensors connected to a single load
Detection parameters
Light parameters
- Time delay: Length of time the load is on after detection.
- Sensitivity: Detection range setting.
Modes:
Auto on/Auto off mode: Comes on automatically:
- At the detection of a presence if there is an insufficient natural level of light.
Turns off automatically:
- If no presence is detected and at the end of the time delay set.
- Or if the natural light level is sufficient (regulation activated) Another detection causes automatic switch-on if there is insufficient light.
Walk-through mode:
- If no presence is detected in the 20 seconds following an initial detec-tion, the product will cut off the load after 3 minutes.
- If another presence is detected in the 3 minutes following initial detec-tion, the device will cut off the load at the end of the set time delay.
Manual on/Auto off mode:
Where no presence is detected and at the end of the time delay set. After
switch-off, any new detection within a 30 second period triggers an automatic
switch-on. The Restart function must be activated. After 30 seconds the device
is switched on via a manual switch.
Detection system:
- Initial detection: The load is switched on as soon as the first detection occurs if the natural light level is below the light level threshold.
- Maintain: The load remains active if another presence is detected.
- Restard: In manual mode. After switch-off, any new detection within a 30 second period triggers an automatic switch-on. After 30 seconds the device must be switched on manually.
- Alarm: an audible signal is emitted before switch-off. (1 minute before, then 30 seconds, then 10 seconds).
- Light level threshold: Value at which the load comes on if the natural light level is less than the setting.
- Caution: At 1275 lux, the device becomes a motion sensor.
Advanced mode:
- Calibration: The ambient light level measured with a luxme-ter must then be transmitted to the sensor (see data sheet Cat. No. 0 882 30).
- Regulation : Automatic switch-off of the load 10 minutes after the light level threshold is exceeded with an additional safety threshold (to avoid lights switching off at the wrong moment).
- Light contribution: Quantity of additional lux provided by the load being switched on.
When the light contribution parameter is set to “Auto” (value 0) on the configuration tool Cat. No. 0 882 30 the sensor automatically calculates the light contribution.
Modifying the parameters using the configuration tools
- 0 882 35: Simplified configuration tool 0 882 30: Advanced configuration tool When the sensor receives an IR command using the configuration tool, it emits a beep acknowledging the modification. For more information about setting parameters, refer to the data sheet for the configuration tool Cat. No. 0 882 30. Range: 1 m. The potentiometers are active by default. Using a configuration tool deactivates all the potentiometers. Reset the product to reactivate them.
Restore to factory settings:
- 1st press: Short press on LEARN: the LED flashes slowly.
- 2nd press: Press and hold down LEARN for 10 seconds until the LED flashes quickly.
PERFORMANCE
1 PIR detection (walk-through)
Sensitivity | Ø (m) |
---|---|
Low (25%) | 7 |
Medium (50%) | 8 |
High (75%) | 10 |
Very high (100%) | 12 |
PIR detection (presence)
Sensitivity | Ø (m) |
---|---|
Low (25%) | 1 |
Medium (50%) | 2 |
High (75%) | 4 |
Very high (100%) | 5 |
CLEANING
Clean the surface with a cloth. Do not use acetone, tar-removing cleaning agents or trichloroethylene. Resistance to the following cleaning substances: Hexane (EN 60669-1), Methylated spirit, Soapy water, Diluted ammonia, Pure bleach diluted to 10%, Window-cleaning products, and Pre-impregnated wipes.
Caution: Always test before using other special cleaning products.
STANDARDS AND APPROVALS
Compliant with installation and manufacturing standards. See e.catalogue.
TROUBLESHOOTING
PROBLEM | CAUSES | SOLUTIONS |
---|---|---|
Lighting stays on when there is no-one present | Sources of interference can | |
cause false tripping, such as: air current, vibrations, radiators | 1- Reduce |
the sensitivity level
2- If the interference continues: using the confi- guration tool, go into the Detection system parameters, select Maintain and then choose PIR
3- If the interference still continues, move the sensor away from sources of interference
Lighting does not switch off during the day when there is an adequate level of natural light| Regulation function not active Light level threshold set too high Light contribution is too high| Activate the regulation function Reduce the light level threshold
Check that the sensor is positioned correctly in relation to the window
Decrease the power of the luminaires
Lighting switches off when there are people present and the natural light level is not ade- quate (darkness)| Time delay too short Detection sensitivity too low Light level threshold too low| Increase the time delay
10 to 1 minutes is recommended for work areas Increase the sensitivity
Move the sensor closer to the work area Increase the threshold