Midea 0.66 Cu Ft. 2000W FlashChef High Speed Oven Heavy Duty Microwave User Manual
- June 10, 2024
- Midea
Table of Contents
Midea 0.66 Cu Ft. 2000W FlashChef High Speed Oven Heavy Duty Microwave User
Manual
Installation Environment
Supporting systems:
Windows: Win7+
OS: MacOS
Installation Instructions
Double-click FlashTune.msi or FlashTune.dmg to enter Windows or OS
installation guide respectively, and install as prompted.
The operation logics and function applications of FlashTune are completely consistent on Windows and OS, and the following description is for Windows only
Interface Description
Open Application
-
In the application installation position, open the application and enter the “Start Interface” to initialize the application data.
-
Enter the system interface after start. By default, the system enters the menu interface “MENU”, select “All” to display all recipes by categories.
Main Interface Description
The application is divided into two parts: recipe interface and setting interface. See the figure below:
Recipe interface
Setting interface
Menu area: for menu operation;
Recipe/setting switching: Switch between recipe interface and setting
interface;
Recipe category area: Display all recipe categories, and switch to the current
recipe category;
Recipe area: Display the current recipe category, and switch to the current
recipe;
Cooking parameter setting area: Set the cooking duration of each section of
the recipe, microwave fire, hot air fire, up to 6 sections, cooking duration
of 0~10min, fire range of 0~100%;
Setting area: Set temperature unit, default preheating temperature, ECO,
temperature error, dayshifts
System Menu
File
Data file: The data file used for program running, with file extension of
“.db”. Thegenerated data files can be exported to the machine, and the files
in the machine can be exported and opened in the application.
Open: Open an application data file.
Save: Save application data. For the first save, Save as operation will
be executed.
Save as: Save application data to a specified location.
Exit: Exit the application.
Model
Model is machine model mode, and currently supports FA2 mode. Categories can be added to the database profile.
Language
System language supports Chinese and English versions, and other languages are to be expanded. It needs to be configured in the internationalization file.
About
Display system version information.
Recipe Interface Operation
Click “MENU” in the recipe/setting switching area to enter the recipe
interface.
Create a New Recipe Category
-
Click the in recipe category area to add a recipe category. The interface for adding recipe category appears.
-
Enter the category name in the edit area on the right. Duplicate names will be automatically added with numerical serial number. If there is a Pizza, another Pizza category will automatically become Pizza2.
Edit Recipe Category
-
Click the existing categories in the recipe category area to open the recipe category editing interface.
-
Modify the category name in the edit area on the right. Duplicate names will be automatically added with numerical serial number. If there is a Pizza, another Pizza category will automatically become Pizza2.
Delete Recipe Category
-
In the recipe category editing interface, click to pop up deletion confirmation.
-
After confirming the deletion, the system will delete the category and all recipes under the category.
Create a New Recipe
-
Click Recipe Category to enter recipe editing interface.
-
Click in the recipe area to add a new recipe.
-
Enter the recipe name and temperature.
-
Set recipe icon:
-
a) Click to enter the recipe icon selection interface.
-
b) Select the required icon and click to complete the selection.
-
c) To use an uploaded picture as an icon, click to enter the icon uploading interface.
-
d) Edit the picture and click to complete the selection.
-
-
Edit cooking parameters:
-
a) There are six sets of cooking parameters, and the editing of the next set will not be enabled before the previous data are completed. There must be a set of data before save
-
b) Click to clear a set of data, and the previous data will move forward
-
-
Click to save the edited data.
Edit Recipe
- Click Recipe Category to enter recipe category editing interface.
- Click the recipe to be edited in the recipe area to enter the recipe editing interface.
- Edit the recipe data with the same method as “Add a Recipe”.
Delete Recipe
-
Click Recipe Category to enter recipe category editing interface.
-
Click the recipe to be edited in the recipe area to enter the recipe editing interface.
-
Click in the recipe editing interface to pop up deletion confirmation
-
The recipe is deleted after confirmation.
Setting Interface Operation
Click “Settings” in the recipe/setting switching area to enter the setting
interface.
Start Setting
To prevent misoperation, there is a write-in switch in the recipe/setting
switching areaof the setting interface. Only when the switch is valid, the
data in the setting area can be modified, otherwise, the data are locked. The
machine will not read the new configuration when the write-in switch is
invalid.
Temperature Unit Setting
The system supports Celsius temperature (°C) and Fahrenheit temperature (°F). The display of data and units will be affected by the switching of units. During switching, the set data will be automatically saved and reloaded.
Preheating Temperature Setting
The preheating temperature can be set in three groups, ranging from 200°F to 527°F.
ECO Setting
Time range: 10~60M, step: 10M; power range: 10%~100%, step: 10%
Once the time and power in STAGE1 are set, the time and power in STAGE2 are
limited to the optional range, time is greater than that in Stage 1, and power
is less than that in Stage 1;
Example: Set Stage 1: time to 50M, power to 60%, stage 2: Optional range of
time is 60, and optional range of power is 10-50%;
Temperature Difference Range Setting
The temperature difference range is 18F by default, or select one of them.
Period Temperature Setting
The period temperature saves 7 groups of data from Monday to Sunday. Each group can be set with three parameters of Preiod1~Preiod3. The time system adopts 12h, default period is AM 00:00, and default TEMP is 00. When the data is 00 by default, it is considered that there is no setting. TEMP ranges from 200°F to 527°F.