General Remark

  • The installation and maintenance has to be carried out by qualified professions or Midea authorized technicians.
  • The manufacturer shall not be held responsible for any damage or malfunction caused by wrong installation or failing to comply with following instructions included in this pamphlet.
  • For more detailed installation and maintenance guidelines, please refer to below chapters.

CAUTIONS

Before installing this water heater, check and confirm that the earthing on the supply socket is reliably grounded. Otherwise, the electrical water heater can not be installed and used. Do not use extension boards. Incorrect installation and use of this electrical water heater may result in serious injuries and loss of property.

Special Cautions

  • The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electrical leakage. Inspect frequently whether the plugs contact well with the socket. Inspect method is as follows: insert the power supply plug into socket, after using for half an hour, shut down the unit and pull the plug out, and inspect the plug whether it scalds hand. If it scalds (over 50¥), please change another well-contacted socket to avoid the plug being damaged, fire or other personnel accidents result from bad-contacting.

  • The installation height of the supply socket shall not be lower than 1.8m.

  • The wall in which the electrical water heater is installed shall be able to bear the load more than
    two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthening measures shall be adopted.

  • The pressure relief valve attached with the heater must be installed at the cold water inlet of this heater(see Fig.1), and make sure it is not exposed in the foggy. The water may be outflowed from pressure relief valve, so the outflow pipe must open wide in the air; The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not be blocked.
    Midea D30 15FA3 1500W 30L Electric Water Heater - CAUTIONS
1

  • When using the heater for the first time(or the first use after maintenance), the heater can not be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water.

  • The water heater is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the heater.

  • During heating, there may be drops of water dripping from the pressure release hole of the multifunction valves. This is a normal phenomenon. If there is a large amount of water leak, please contact customer care center for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in accidents.

  • The drainage pipe connected to the pressure release hole must be kept sloping downwards.

  • Since the water temperature inside the heater can reach up to 75°C, the hot water must not be exposed to human bodies when it is initially used. Adjust the water temperature to a suitable temperature to avoid scalding.

  • Unscrew the thread screw on the multifunction safety valve, and lift the drain handle upwards. (See Fig.1) to drain the water from the inner tank.

  • If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected, and replaced by the professional maintenance personnel. If any parts and components of this electrical water heater are damaged please contact customer care center for repair.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance.

PRODUCT INTRODUCTION

Technical Performance Parameters

Model| Volume
(L)| Rated
Power
(W)| Rated Voltage (ACV)| Rated Pressure (MPa)| Max Of Water
Temperature (°C)| Protection
Class| Water Proof Class
---|---|---|---|---|---|---|---
D30-15FA3| 30| 1500| 220-240| 0.8| 75| I| IPX4
D50-15FA3| 50| 1500| 220-240| 0.8| 75| I| IPX4
D80-15FA3| 80| 1500| 220-240| 0.8| 75| I| IPX4
D100-15FA3| 100| 1500| 220-240| 0.8| 75| I| IPX4

Brief introduction of product structure

Midea D30 15FA3 1500W 30L Electric Water Heater - PRODUCT INTRODUCTION
1

| D30-15FA3| D50-15FA3| D80-15FA3| D100-15FA3
---|---|---|---|---
A| 340| 450| 450| 450
B| 594| 600| 809| 974
C| 100| 100| 100| 100
D| 200| 200| 200| 200

Internal Wire Diagram

Midea D30 15FA3 1500W 30L Electric Water Heater - PRODUCT INTRODUCTION
2

UNIT INSTALLATION

Installation Instruction
  1. This electrical water heater shall be installed on a solid wall. If the strength of the wall cannot bear the load equal to two times of the total weight of the heater filled fully with water, it is then necessary to install a special support. Incase of hollow bricks wall, ensure to fill it with cement concrete completely.

  2. After selecting a proper location, determine the positions of the two install holes used for expansion bolts with hook (determined according to the specification of the product you select). Make two holes in the wall with the corresponding depth by using a chopping bit with the size matching the expansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electric water heater on it (see Fig.2).
    Midea D30 15FA3 1500W 30L Electric Water Heater - UNIT INSTALLATION
1

  3. Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, three electrodes. It is recommended to placed the socket on the right above the heater. The height of the socket to the ground shall not be less than 1.8m (see Fig.3). If there is fault on power cable, it should be replaced by the manufacturers, agencies or qualified person who is able to do this so as to ensure the safety.
    Midea D30 15FA3 1500W 30L Electric Water Heater - UNIT INSTALLATION
2

  4. If the bathroom is too small, the heater can be installed at another place without sun-scorched and rain-drenched. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location shall be as near as possible to the heater.

Pipelines Connection
  1. The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as the unit; The minimum pressure of inlet should use Pa as the unit.

  2. Connection of pressure relief valve with the heater on the inlet of the water heater.

  3. In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the heater must be added at the end of the threads to ensure leak proof joints (see Fig.4).
    Midea D30 15FA3 1500W 30L Electric Water Heater - UNIT INSTALLATION
3

  4. If the users want to realize a multi-way supply system, refer to the method shown in fig.5 for connection of the pipelines.
    Midea D30 15FA3 1500W 30L Electric Water Heater - UNIT INSTALLATION
4

NOTE
Please be sure to use the accessories provided by our company to install this electric water heater. This electric water heater can not be hung on the support until it has been confirmed to be firm and reliable. Otherwise, the electric water heater may drop off from the wall, resulting in damage of the heater, even serious accidents of injury. When determining the locations of the bolt holes, it shall be ensured that there is a clearance not less than 0.2m on the right side of the electric heater, to convenient the maintenance of the heater, if necessary.

METHODS OF USING

  • First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet valve. The water heater gets filled with water. When water flows out of the outlet pipe it implies that the heater has been filled fully with water, and the outlet valve can be closed.
    NOTE
    During normal operation, the inlet valve shall be always kept open.

  • Insert the supply plug into the supply socket, the two indicator lights will light up this time.

  • The thermostat will automatically control the temperature. When the water temperature inside the heater has reached the set temperature, it will switch off automatically, when the water temperature falls below the set point the heater will be turned on automatically to restore the heating.

MAINTENANCE

WARNING

Do cut off power supply before maintenance, to avoid danger like electric shock.

  • Temperature limiter cut off electricity if water heater is overheated or thermostat damages. Manual resetting is needed. Resetting knob is as follows (see Fig.6). Non-professionals are not allowed to disassemble temperature limiter to reset . Please contact professionals to maintain. Otherwise our company will not take responsibility if any quality accident happens because of this.
    Midea D30 15FA3 1500W 30L Electric Water Heater - METHODS OF USING
1

  • Check the power plug and outlet as often as possible. Secure electrical contact and also proper grounding must be provided. The plug and outlet must not heat excessively.

  • If the heater is not used for a long time, especially in regions with low air temperature(below 0°C), it is pessary to drain water from the heater to prevent damage of the water heater, due to water freezing in the internal tank.(Refer Cautions in this manual for the method to drain away the water from the inner container).

  • To ensure long reliable water heater operation, it is recommended to regularly clean the internal tank and remove deposits on the electric heating element of the water heater, as well as check condition (fully decomposed or not) of the magnesium anode and, if necessary, replace it with a new one in case of full decomposition. Tank cleaning frequency depends on hardness of water located in this territory. Cleaning must be performed by special maintenance services. You can ask the seller for address of the nearest service center.

TROUBLESHOOTING

Failures Reasons Treatment
The heating indicator light is off. Failures of the temperature controller.

Contact with the professional personnel for repair.
No water coming out of the hot water outlet.| 1. The running water supply is cut off.
2. The hydraulic pressure is too low.
3. The inlet valve of running water is not open.| 1. Wait for restoration of running water supply.
2. Use the heater again when the hydraulic pressure is increased.
3. Open the inlet valve of running water.
The water temperature is too high.| Failures of the temperature control system.| Contact with the professional personnel for repair.
Water leak.| Seal problem of the joint of each pipe.| Seal up the joints.

NOTE
Parts illustrated in this use and care manual are indicative only, parts provided with the product may differ with illustrations.This product is intended for household use only. Specifications are subject to change without notice.

Produce information with EU regulation

The electrical storage water heater D30-15FA3 of the company MIDEA Ltd. was tested with a declared load profile of the size “S”
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of  ηwh=32% that correspond to the water heating efficiency class “C”
In accordance with Annex Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec, water heating energy efficiency ηwh and mixed water at 40ºC (V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Cord -0.414 kWh
Referent energy REL 2.1 kWh
Useful energy content QH20 2.5 kWh
Correction ratio of reference and useful energy Reef/QH20 0.84 kWh
Daily electricity consumption (measured) Qtest_eiec 3.520 kWh
Water temperature at the beginning of the 24h measurement cycle T3 66.4 ºC
Water temperature at the end of the 24h measurement cycle T5 71 ºC
Storage volume Mad 30.3 kg
Storage volume Cad 30.3 L
Daily electricity consumption (corrected) Qila 2.820 kWh
Water heating energy efficiency ηth 31.6
Annual Electricity Consumption AEC 583 kWh
Water heating energy efficiency class C
Description Parameter Value Unit
Water temperature without tapping Stet 66 ºC
Average water temperature of outlet warm water θ’p 62.0 ºC
Average water temperature of inlet cold water θc 10.5 ºC
Normalized value of the average temperature θp 62.2 ºC
Volume that delivered water of at least 40 C V40exp 25 L
Calculated volume that delivered hot water of at least 40 C V40 44 L

The electrical storage water heater D50-15FA3 of the company MIDEA Ltd. was tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=37% that correspond to the water heating efficiency class “C” In accordance with Annex Energy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ERP-Label. Electricity consumption Elec, water heating energy efficiency ηwh and mixed water at 40ºC (V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Cora -0.395 kWh
Referent energy REL 5.845 kWh
Useful energy content QH20 5.73 kWh
Correction ratio of reference and useful energy QreeQH20 1.038 kWh
Daily electricity consumption (measured) Estelle 6.527 kWh
Water temperature at the beginning of the 24h measurement cycle T3 58.6
Water temperature at the end of the 24h measurement cycle T5 62.7
Storage volume Mast 49 kg
Storage volume Cart 49 L
Daily electricity consumption (corrected) Elec 6.532 kWh
Water heating energy efficiency ηwh 36.68
Annual Electricity Consumption AEC 1400 kWh
Water heating energy efficiency class C
Description Parameter Value Unit
Water temperature without tapping Tot 60 °C
Average water temperature of outlet warm water θ’p 59.8 °C
Average water temperature of inlet cold water θp 8.8
Normalised value of the average temperature θP 59.9
Volume that delivered water of at least 40°C V40exP 38 L
Calculated volume that delivered hot water of at least 40°C V40 63 L

The electrical storage water heater D80-15FA3 of the company MIDEA Ltd. was tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=36% that correspond to the water heating efficiency class “C” In accordance with Annexû Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ERPs-Label. Electricity consumption Elec, water heating energy efficiency ηwh and mixed water at 40°C (V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Cora -0.335 kWh
Referenct energy Reef 5.845 kWh
Useful energy content QH2O 6.135 kWh
Correction ratio of reference and useful energy Reef/QH2O 0.953 kWh
Daily electricity consumption (measured) Qtest_eiec 8.537 kWh
Water temperature at the beginning of the 24h measurement cycle T3 51.8
Water temperature at the end of the 24h measurement cycle T5 70.9
Storage volume Mact 80.6 kg
Storage volume Cact 80.6 L
Daily electricity consumption (corrected) Qelec 6.428 kWh
Water heating energy efficiency ηwh 36.4
Annual Electricity Consumption AEC 1382 kWh
Water heating energy efficiency class C
Description Parameter Value Unit
Water temperature without tapping Tset 52
Average water temperature of outlet warm water θ’p 50
Average water temperature of inlet cold water θc 10.5
Normalised value of the average temperature θp 49.9
Volume that delivered water of at least 40℃ V40exp 56 L
Calculated volume that delivered hot water of at least 40℃ V40 75 L

The electrical storage water heater D100-15FA3 of the company MIDEA Ltd. was tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission regulation standards (No 814/2013) for electrical storage water heater and achieved a water heating energy efficiency of ηwh=36% that correspond to the water heating efficiency class “C” In accordance with Annexû Enercy Efficiency Classes article 1 of the commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with the related commission regulation (No 812/2013 and 814/2019) is only a part of the conformity assessment to achieve the ErP-Label. Electricity consumption Qelec, water heating energy efficiency ηwh and mixed water at 40℃ (V40)

Description Parameter Value Unit
k-Value k 0.23
Smart control compliance smart 0
Smart control factor SCF 0
Conversion coefficient CC 2.5
Ambient correction term Cora -0.464 kWh
Referenct energy Reef 5.845 kWh
Useful energy content QH2O 6.243 kWh
Correction ratio of reference and useful energy Reef/QH2O 0.936 kWh
Daily electricity consumption (measured) Qtest_eiec 9.394 kWh
Water temperature at the beginning of the 24h measurement cycle T3 51.3
Water temperature at the end of the 24h measurement cycle T5 70.8
Storage volume Mast 100.9 kg
Storage volume Cast 100.9 L
Daily electricity consumption (corrected) Elec 6.653 kWh
Water heating energy efficiency ηwh 36.2
Annual Electricity Consumption AEC 1420 kWh
Water heating energy efficiency class C
Description Parameter Value Unit
Water temperature without tapping Tet 51
Average water temperature of outlet warm water θ’p 50.7
Average water temperature of inlet cold water θc 10.3
Normalised value of the average temperature θp 50.7
Volume that delivered water of at least 40℃ V40exp 76.3 L
Calculated volume that delivered hot water of at least 40℃ V40 103 L

The product is subject to change without notice. Please keep this manual properly.

Wuhu Midea Kitchen & Bath Appliances Mfg. Co., Ltd.
Address: East Road Watchung, East Area Economic & Technological Development Area, Wuhu City, Anhui Province, P.R.China
Web site: www.midea.com/global Postal code: 241000

Midea Italia Seral.
A Socio Unico Vaile
Bodied 29 20158 Milano
(MI) www.midea.com/it

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Midea User Manuals

Related Manuals