schweigen 90cm Silent Undermount Rangehood with Isodrive 900 Single Motor Installation Guide
- June 5, 2024
- schweigen
Table of Contents
**schweigen 90cm Silent Undermount Rangehood with Isodrive 900 Single
Motor**
Welcome
Thank you for purchasing your new Schweigen Isodrive system.
To get the maximum output from this unit, please read through this guide
before use and installation.
This guide contains important information on the correct use and maintenance
of the unit, as well as important safety notes. This will ensure your personal
safety and the lasting value of your Isodrive system.
Please always retain your proof of purchase to aid in any warranty queries.
This appliance and its packaging are produced by processes that minimize waste
and respect the environment.
Please help us to continue this effort to protect the environment by using the
appliance efficiently and disposing of the packaging in a responsible manner.
Your Safety
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the
appliance. Inspect your product upon receipt. Any damage or defects MUST be
reported within 48 hours, or no claim will be recognised.
DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.
If this product is installed damaged, the supplier, nor the retailer, will be
responsible for the costs associated with the repair, replacement, removal or
re-installation of the appliances.
This appliance is not intended for use by person/s (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and/or
knowledge. Unless the person has been given supervision
or instruction concerning the use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play
with the appliance, it is not a toy.
Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood.
If you fail to do so, your warranty will be voided.
The manufacturer declines all responsibility in case of failure to adopt
proper safety measures.
Ensure that the location in which this appliance is installed, has good and
permanent ventilation.
Please consult local laws and regulations and install in accordance.
Use an electrical connector with earth that is correct for your location.
Check that the voltage in your area corresponds to the appliance as indicated
on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by an experienced Home
Appliances technician. Please see our website www.schweigen.com.au for
experienced installers.
It is dangerous to modify any part of this appliance. Modification of any
kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If
the supply cord is damaged, it must be replaced by the manufacturer, service
agent or a similarly qualified person in order to avoid a hazard. The power
supply cord connection MUST BE installed in such a way that access is easy in
case of emergency.This guide is for the installation of the motor used in the
Isodrive systems after the canopy/rangehood or bathroom extraction grill has
been mounted on the wall or ceiling. (Refer to canopy/rangehood or bathroom
extraction unit installation manual).
NOTE: All PVC pipe and SteelFlex™ ducting measurements are referring to
inside measurements, unless otherwise mentioned..
Motor Features
- Roof and wall mounting with IPX4 degree of weather protection.
- Patented anti water intrusion system.
- Super quiet, long vane, backward curved centrifugal fan.
- Airflow is dependant on installation and the ducting used. Using a single 200mm SteelFlex™ duct, you should attain up to 900m3/hr depending on the ducting installation. The use of a smaller than 200mm ducting would result in a loss of airflow.
- Simple installation: The motor mounts onto a 150mm PVC pipe for ultimate strength and allows for easy Dektite roof sealing.
- Industrial quality motor and fan made in Germany and rated at 40,000 hours.
- Motor is a high efficiency PSC type and rated at 57W.
- WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear, chemical or storm damage etc. (see warranty card for more information).
General Notes on Installation and Use
This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the
initial connection duct to the fan module, and is supplied with a 150mm (ISD)
PVC pipe to 200mm SteelFlex™ duct bell-mouth adaptor.
This fan is suitable for connection to ducting runs with a minimum inlet area
of 22,000mm2 and length up to 8 metres maximum (check with supplier if longer
duct length required). SteelFlex™ ducting must be extended sufficiently to
present a smooth air passage with bends of at least the radius of twice the
diameter of the duct.
Excessive bends in the ducting will compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling
space, where a build up of grease can occur and become a potential fire risk.
This will void your warranty.
NOTE: Fan module and Steelflex™ duct are acoustically matched. Use of
semi-rigid or rigid ducting will result in increased noise and may void
warranty. See installation instruction notes ‘Why Schweigen SteelFlex™ Safety
Duct’.
Recommended Installation Distance
Isodrive 900 motor, recommended 4 meters of SteelFlex™ ducting and with at
least two bends.
NOTE: Installation closer than this distance may result in a higher noise
level. The maximum duct length is 8 meters. Check with the supplier if a
longer duct length is required. Do not reduce the duct size at any time and
avoid sharp bends.
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 meters
(measured to the lower part of the fan impeller) above a floor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the backflow of gases into the room from the
open flue of gas or other open fire appliances.
Safety of Children
This fan is not intended for use by young children or infirm persons without
supervision.
Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or
suitably qualified person in order to avoid a hazard.
Why Schweigen SteelFlex™ Safety Duct
Schweigen SteelFlex™ is an ultra-strong and flexible high-performance safety
ducting made of Shirikon Firemesh® – a tri-layer tear-resistant UV-treated
sleeve. Both are developed by Schweigen – the Silent Rangehood specialists,
for quiet and efficient high-volume transfers
of temperature-sensitive air. Engineered to enhance the health and safety of
your home, Schweigen SteelFlex™ is antimicrobial treated, thermally insulated
and acoustically dampened. It is fireproof, pest and crushproof with a treated
surface that prevents the build-up of grease and bacteria.
Schweigen’s unique Isodrive system works in the opposite way to conventional
range hoods, pulling air through the hood and acoustically matched ducting,
producing almost silent high volume flow. The use of a complete rigid or semi-
rigid ducting system will allow an organ piping effect to occur; like a
didgeridoo where noise is produced at one end of a hollow rigid pipe and the
noise is amplified out the other.
The Isodrive system places the noise outside the house.
WARNING: Installation without the use of at least the minimum recommended
length of acoustically matched SteelFlex™ in the system will void performance
expectations. Any installation problem must be reported
to Schweigen. Call-outs relating to incorrect installation will result in a
service fee direct to the customer. Schweigen takes no responsibility for
problems caused by faulty installation, this may void warranty.
An experienced installer list can be obtained from the Schweigen website
www.schweigen.com.au or by calling 1300 881
693.
Description
NOTE
For more SteelFlex™ ducting instructions, refer page 16.
- Isodrive Motor
Included in the box:
1. Isodrive 900 motor (280W x 200H mm approx.) Approx. 3 metre, 10amp cable and standard plug
2. Fire resistant 150mm (160mm outside dimension) PVC riser pipe
3. SteelFlex™ safety ducting. Approx. 4 metres, 200mm (210mm outside dimension) diameter
4. Bell-mouth adapter ring
200mm duct to 150mm riser
5. 2 x Steel ring clamps
(for attaching ducting to rangehood and motor)
6. 6 x 20mm self-drilling button head screws
Not included in the box:
- Roof seal kit / Dektite
- Support straps for the poly pipe which connects to the roof truss
- Aluminum foil tape
- Wall Cover Plate (wall mount only) – optional Part number P1108
- Mounting Flange (wall mount only) – optional Part number P40113MF
- Backdraft Shutter – optional
Part number 200MMBDSSBUILD
Installation
Roof Installation
Recommended duct length: 900 motor — minimum 4 meters.
Mount 150mm (ISD) rigid PVC pipe securely to beams, trusses or other
appropriate structures: refer figure 1. The pipe should be mounted vertically
with the roof penetration being sealed using a Dektite or other appropriate
sealing membrane or device.
Ensure that the PVC pipe protrudes a minimum of 50mm past the top of the
Dektite, checking that the fan assembly clears the roof cladding at upper edge
as shown in figure 1 — Roof Mount Option.
Pass power cord and plug through mounting flange and pipe, then out the
slotted PVC pipe for connection to the socket coming from the
canopy/rangehood. Refer to figure 4.
Do not insert plug into socket outlet or switch on until installation has been
completed. Fit fan module to pipe and fix in position using side locking
screw.
Certain external installation configurations may cause audible levels of noise to be heard due to the air being expelled from the motor. To minimize external noise disturbance you can use between 4 to 8 metres of SteelFlex™ duct to place the Isodrive motor in an appropriate position.
Please be aware that the 900 motor is capable of expelling air at 900m3/hr.
For more information on environmental noise limit and conditions please
contact your local Council. We have a list of experienced installers available
on the Schweigen website.
Do not install the SteelFlex™ in a straight line and minimum of two gentle
bends in the ducts is required.
IMPORTANT
For more SteelFlex™ ducting instructions, refer to page 16.
Wall Installation
This type of installation is similar to roof mounting, ensuring that the pipe
extends at least 50mm past the wall surface refers to figure 2. If the pipe
length is shortened, reproduce the power cord exit slot on the inside of the
wall.
NOTE: By decreasing the length of the SteelFlex™ duct from which specified (refer to installation instructions) there will be an increase in airflow and noise levels as a result. This increase in airflow can cause movement of air to be heard through the system and inhibit the system to run silently.
IMPORTANT
For more SteelFlex™ ducting instructions, refer page 16.
Flat Roof Installation
Flat roof mounting using optional mounting flange*.
IMPORTANT
For more SteelFlex™ ducting instructions, refer page 16.
Through Wall Installation for Isodrive 900
Fan Unit Shutter Assembly for Isodrive 900 (Optional)
- Assemble by fitting shutter assembly into fan inlet shroud molding, ensuring that attaching screws align with holes. Alignment can be checked visually by folding in shutter flaps.
- Fully tighten both screws and re-check fitment into holes.
- Fit assembly to duct pipe as per installation instructions supplied.
Measurements for Isodrive 900 (Not to Scale)
SteelFlex™ Safety Duct
SteelFlex™ Safety Ducting
SteelFlex™ safety ducting must be fully extended and cut to the required
length upon installation. Maximum fan performance will not be achieved unless
the ducting is fully extended. Failure to fully extend ducting results in a
smaller air passage and lower airflows. Incorrect installation may reduce
airflow or increase noise levels. Call-outs relating to incorrect installation
will result in a service fee directed to the customer. Schweigen will take no
responsibility for problems caused by faulty installation. A list of
experienced installers can be obtained from the Schweigen
websitewww.schweigen.com.au.
Assembling SteelFlex™ Safety Duct
SteelFlex™ safety duct must be secured to either the bell-mouth adapter ring
or a 200mm mounting pipe.
Parts required:
- SteelFlex™ safety ducting
- Steel ring clamp
- Bell-mouth adapter ring 200mm duct to 150mm riser
- 150mm PVC riser pipe
- 5. 20mm self-drilling button head screws
- Slide the steel ring clamp over the end of the duct then insert the bell-mouth adapter ring into the duct end
- Secure duct to the bell-mouth adapter at regular intervals with 4 x 20mm button head screws
- Slide the steel ring clamp back up and tighten to secure the bell-mouth adapter and the duct
- Attach the mounting pipe to the bell-mouth adapter and secure with 1 x 20mm button head screw
NOTE: Do not use duct tape to fasten the duct – the screws and hose clamp are adequate to secure the duct to the bell-mouth adapter ring.
Shallow Roof Space
In shallow roof spaces, do not crush or kink SteelFlex™ ducting, as it will
reduce airflow severely. A 90-degree curve made of PVC or galvanize can be
used as a substitute for the bend, refer to figure 12.
Important Note
Please do not crush or kink SteelFlex™ ducting, as it will reduce airflow and
may cause noise to occur through the system. Ducting needs to be kept taut at
all times.
Securing SteelFlex™ Safety Duct
SteelFlex™ safety duct must be installed with supports at maximum intervals of
1.5 meters. SteelFlex™ safety ductwork can be supported by using good quality
gaffer or aluminium foil tape. Provided that it does not restrict the internal
diameter of the ducting. Ducting installed looped overhanging beams should be
installed in such a manner as to ensure the changes of direction are gradual.
Support of the ducting with the use of hangers may be required, see option 2.
NOTE: Ducting should be kept taut at all times.
Parts List
Parts List for Isodrive 900
Parts List for Isodrive 900
Number | Part Number | Description | Quantity |
---|---|---|---|
1 | P40100 | Terminal Block Cover | 1 |
2 | P40121 | Wire Insulator Cap | 1 |
3 | P1061 | O Ring 4¼” ID | 1 |
4 | P1059 | Capacitor 2μF | 1 |
5 | P807 | Terminal Block | 1 |
6 | P40102 | Fan Plate – Motor Mount | 1 |
8 | P40122 | 900 Inlet Shroud Mount | 1 |
9 | P1069 | 150mm Slotted Pipe | 1 |
10 | P40114 | Bell Mouth Adaptor | 1 |
11 | P40101 | Fan Shroud | 1 |
12 | P301 | Power Cable | 1 |
Maintenance
Roof Restoration or Cleaning
Before doing your roof restoration or cleaning, please completely cover the
outside motor system and avoid all chemical contact.
IMPORTANT
Any damages caused by the use of chemical products are not covered by a
warranty.
Warranty / Disclaimer
Warranty (See warranty for more information)
The isodrive motor has a 10-Year replacement product warranty. The consumer is responsible for any charges associated with the removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in this change-over process. Schweigen SteelFlex™ comes with a Lifetime Warranty.
Disclaimer
Under our policy of continuous product development, product specifications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale. All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.
- Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693
- Email sales@schweigen.com.au
- Web www.schweigen.com.au
- New Zealand 5 Tolich Place, Henderson, Auckland 0610.
- Phone 0800 200 510
- Email info.parex@emerson.com
- Web www.parex.co.nz
References