105W 2ft Linear High Bay
Product Information
The SimplyRetrofit product is designed to provide the end-users with options to adjust color temperature and lumen output as per their requirement. The product has two DIP switches, power switch, and color temperature switch that can be easily adjusted to the desired value.
- Field-Adjustable Wattage and CCT
- CCT Switch Wattage Switch
- Factory Settings: 5000K, 210W
Product Usage Instructions
Follow the below instructions to use the SimplyRetrofit product:
-
Locate the DIP switches on the side of the fixture.
-
Select the desired wattage by sliding the power switch left or middle or right.
-
Select the desired color temperature by sliding the color temperature switch left or right.
-
The three power options and two color temperature options correspond to desired color temperature and lumen output combination.
-
By default, the factory settings are 5000K and 210W. Adjust the
DIP switches as per your requirement. -
Refer to the product user manual for further instructions or technical details.
For more information or support, visit www.simplyretrofits.com.
Installation Guide
WARNING
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/ abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
- For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code.
- To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
- Do not make or after any open holes in an enclosure of wiring or electrical components during kit installation.
WARNING
- Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
- Turn off the power when you perform any maintenance.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- All wiring connections should be capped with UL approved wire connectors.
CAUTION
- Avoid direct eye exposure to the light source while it is on.
- Account for small parts and destroy packing material, as these may be hazardous to children. Risk of bun.
- Disconnect power and allow fixture to cool before changing bulb or handing fixture.
NOTICE: Green ground screw provided in proper location. Do not relocate.
NOTICE: Minimum 90 supply conductors.
NOTICE: Specifications and dimensions subject to change without notice.
NOTICE: Suitable for Dry or Damp location.
General Wiring Diagram
Installation Step:
Always turn off the power supply from main circuit breaker first!
Remove the new LED fixture from packaging and inspect for any damages. Handle
new LED fixture with care. CHAIN MOUNT EXAMPLE; Install the chain into the
provided wire hanger. Secure the other end of the chain to a structure using
hardware rated for the load.Install the wire hanger onto the side of the top
ETLB7 LED channel. Make sure the wiring hangers are fully engaged into the
side holes on the top channel. Connect the LED high bay wiring to line wire,
black to black, white to white and green to green. Use only UL listed wiring.
*NOTE: Purple and grey lead inside the driver compartment are 0-1oV (low
voltage) dimming leads. Connect to dimming low voltage wining only. Clean II
residues/fingerprints from the new LED high bay and lens. Double check all
hanging hardware before moving onto the next installation.
Field-Adjustable Wattage & CCT
The end users may adjust the color temperature and lumen output respectively by the two DIP switch. The power switch has three options (left, middle and right), and the color temperatures switch has two options (left and right), corresponding to three powers and two color temperatures respectively, which can perform the desired color temperature and lumen output combination.
Factory Settings: 5000K,210W
- DIP switches are located onto the side of the fixture.
- Select a wattage and color temperature by sliding switch left or right respectively to the desired value.