LITHONIA LIGHTING TDD LED 2 Dusk to Dawn LED Area Light Instruction Manual

June 10, 2024
LITHONIA LIGHTING

LITHONIA LIGHTING TDD LED 2 Dusk to Dawn LED Area Light Instruction Manual

Protect yourself. Before installing, read the entire instructions carefully and save them for future reference.
Date installed: ___

FIXTURE PACKING LIST

Description__Quantity

  1. Housing Assembly ……………………..1
  2. Photocontrol …………………………….. 1
  3. 1” Bolts* ……………………………………. 2
  4. 2” Wood Screws* ……………………….. 3
  5. Cover Plate* …………………………….. 1
  6. Wire Nuts* ……………………………….. 3
  7. Diffuser* ………………………………….. 1

*Contained in parts packs

Mounting Hardware Included
Waterproof Supply Fittings & Conduit will be required – Purchase Separately Silicone Sealant Required

REQUIRED TOOLS

REQUIRED TOOLS

If this fi xture fails to operate properly, use the guide below to diagnose and correct the problem.

Trouble Shooting Guide

  • Verify that power is turned on at switch and breaker
  • Verify that fi xture is wired properly
  • Verify that line voltage is correct.

Test if Photocontrol works properly
The photocontrol in this fi xture is designed to turn on fi xture light at low light levels.
If light does not come on or stays on:
Test if Photocontrol works properly:

  • Cover Photocontrol – Light should come on.
  • Shine a fl ashlight into Photocontrol – Light should go off.

If fi xture cylcles on and off:
Light refl ecting back off any surrounding surfaces enters the photocontol. To correct problem, reposition the fi xture or eliminate refl ective surface.

If further technical assistance is required, contact: Technical Support at: 800-279-8041

This LED light provides low maintenance service with no bulbs to change. Clean surfaces with mild soap and water. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

WARNING: There are no user serviceable parts inside fi xture.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW THESE SAFETY INSTRUCTIONS!

  • To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fi xture box and all fi xture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Commercial installation, service and maintenance of luminaires should be performed by a qualifi ed licensed electrician.
  • For Residential installation: If you are unsure about the installation or intenance of the luminaires, consult a qualifi ed licensed electrician and check your local electical code.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fi xture maintenance programs are recommended.
  • This fi xture is intended to be connected to a properly installed and grounded UL listed junction box.
  • It will occasionally be necessary to clean the outside of the refractor/ lens. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confi rm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered suffi ciently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved wire connectors.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING RISK OF BURN

  • Allow lamp/fi xture to cool before handling. Do not touch enclosure, lens or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and restrictions including but not limited to: driver type, burning position, mounting locations/methods, replacement and recycling.
  • Use only lamps that comply with ANSI standards.

CAUTION RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/ lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat.

CAUTION RISK OF PRODUCT DAMAGE

  • Never connect components under load.

  • Do not mount or support these fi xtures in a manner that can cut the outer jacket or damage wire insulation.

  • Unless individual product specifi cations deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensor, timing device, or other related control devices. LED fi xtures must be powered directly off a switched circuit.

  • Unless individual product specifi cations deem otherwise: Do not restrict fi xture ventilation. Allow for some volume of airspace around the fi xture.
    Avoid covering LED fi xtures with insulation, foam, or other material that will prevent convection or cooling.

  • Unless individual product specifi cations deem otherwise: Do not exceed fi xtures maximum ambient temperature.

  • Only use fi xture in its intended location.

  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.

  • Electrostatic Discharge (ESD): ESD can damage LED fi xtures. Personal grounding equipment must be worn during all installation or servicing of unit.

  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.

  • Some components inside the fi xture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.

  • Changes or modifi cations not expressly approved by Acuity Brands Lighting could void the authority to operate the equipment.

  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specifi c warnings.

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when used in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

5-YEAR LIMITED WARRANTY

Register your warranty on www.lightahome.com/warranty. Your prompt product registration confi rms your right to the protection available under the terms and conditions of your Lithonia Lighting warranty.

Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibilities for claims arising out of improper or careless installation or handling of its products.

INSTALLATION INSTRUCTIONS

Remove fi xture components and parts pack. Check to ensure all parts are included. Note: Account for small parts and destroy packing material, as these may be hazardous to children.

Turn OFF Power at circuit breaker box!
CAUTION : Do not rely on wall switch alone to turn off power.

Note: NOT suitable for use with dimmers, motion sensors or other remote devices.

Photocontol Installation

Install Photocontrol by aligning the arrow on top of the Photocontrol with the arrow on the receptacle. Push down and twist clockwise until it clicks.
Installtion Instuction

Note: For optimal performance the arrow on the photocontrol should be facing north after fi xture is installed. If adjustment is needed, loosen the Screw in the center of the white photocontrol receptacle two turns. Rotate receptacle so that the arrow will point north when installed and re-tighten Screw. Note: There is a stop to prevent the receptacle from turning all the way around.
If you have trouble turning the receptacle, try turning it the other direction.

Note: Keep photocontrol or Shorting Cap installed to ensure that no water will enter photocontrol receptacle.

Fixture Mounting
Note: Hardware included for mounting to wood surfaces only!
Ensure that fi xture is mounted onto structurally sound surface that will support the fi xture.
Optional Mounting Arm available (sold separately)

Mark hole locations using the template on the box and drill 3/16” diameter pilot holes.

Install two 2” Screws (4) in bottom holes, leaving about 3/8” space under the head.

Install the third 2” Screw (4) into the predrilled hole on top and back the Screw out. This will leave the hole threaded and make installation easier.

Place Fixture Housing on the two bottom Screws and install third Screw.

Tighten two bottom Screws to secure fi xture

CAUTION: WIRING AND FIXTURE OPERATION

Make sure power is turned off!
Remove knockout on bottom of Cover Plate (5) and feed house supply wires through hole. Note: This fi xture is intended for use with conduit connectors, conduit and junction box that are UL listed suitable for wet locations and are properly installed and grounded. See Fig. A
Installtion Instuction

Ground fi xture

Use Wire Nut (6) to connect the (copper) house supply ground wire & the (green) fi xture ground wire.

Note: If house wiring does not include a ground wire, consult your local electrical code for approved grounding methods.

For proper connection, place wire nut over wires and twist clockwise until tight.

10. Connect supply wires

Use Wire Nuts (6) to connect the black fi xture wire to the black  power supply wire and the white fi xture wire to the white (neutral) supply wire.

Secure Cover Plate (5) to housing with two 1” Bolts (3).

If desired, install decorative Diffuser. Align the keyholes along the diffuser rim with the 3 screw heads around the edge of the fi xture bottom, push up and rotate counter clockwise to install and tighten screws to secure. See Fig. B.

Installtion Instuction

Turn on electricity at fuse or circuit breaker box and verify success of installation. Note: Test fi xture at night or block Photocontrol.

Apply silicone caulking (not included) for moisture seal.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LITHONIA LIGHTING User Manuals

Related Manuals