Product Information
The product is a cooling facility specially designed for use in hotels, restaurants, supermarkets, and cake houses to display cakes, soft drinks, food, and other perishable items. It has an attractive appearance with high- quality materials, a vacuum movable door, transparent glass, and inner light. The cooling system uses a renowned brand of whole close cooling compressor and all kinds of spare parts. This results in the product having the features of an attractive appearance, rational design, quick cooling, electric saving, low noise, no frost, and suitable temperature.
Main Technical Data
Model| Net Volume| Temperature| Voltage/ Frequency| Input power| Refrigerant/
Injected Rate| Dimension| N.W
---|---|---|---|---|---|---|---
KTH9713R| 380L| 2-10| 220-240V/ 50Hz| 0.400kw| R290/65g| 9007401300mm| –
KTH12713R| 505L| 2-10| 220-240V/ 50Hz| 0.445kw| R290/95g| 12007401300mm| –
KTH15713R| 635L| 2-10| 220-240V/ 50Hz| 0.515kw| R290/145g| 15007401300mm| –
KTH18713R| 780L| 2-10| 220-240V/ 50Hz| 0.560kw| R290/149g| 18007401300mm| –
Safety Attention
- Use a single-phase three-pole power socket and ensure its grounding E is grounded reliably.
- Do not stock volatile, erosive, radioactive, flammable, explosive, poisonous, or polluted dangerous food.
- Do not put the power wire on an aisle to prevent heavy pressure and edge tool from creepage accident.
- Do not wash the showcase with water to prevent short circuits and creepage accidents.
- Cut off the power socket when repairing or replacing the light.
Operation Attention
- If you find a special situation, do not dismantle parts and invite a professional technician to handle it.
- The time between turning off and turning on again should be more than 3 minutes.
- Periodically get rid of dust and oil pollution to improve cooling effect.
- If you stop operating the showcase for a long time, cut off the power, clean it, and put it in a dry and ventilated place. Before operating again, check the electrical wire strictly by a technician.
Familiar Trouble and Salvation
Phenomena | Possible Reason | Check Content | Solvation |
---|---|---|---|
Power has no electric | – | Check by multimeter | Connect power |
Socket is loose | – | Examine | Tighten socket |
Compressor doesn’t work | Thermostat foot is loose | ||
Relay foot is loose | Check by multimeter | ||
Dismantle and check | Joint or tighten it |
Tighten the cover
Indicator doesn’t work| Indicator foot is loose| Dismantle the indicator and
examine it| Replace indicator
Tighten foot
Cooling fan doesn’t work| Fan is bad
Foot is loose| Check by temperature meter
Examine| Replace fan
Tighten foot
Inner temperature has been achieved| Thermostat is bad| Check thermostat|
Replace thermostat
Guarantee
It’s forbidden to tear down the machine or replace the component and refrigeration units by nonprofessional.
WARNING!
Please read the user manual carefully before using the machine.
Description
The product is the cooling facility special designed for hotel, restaurant,
supermarket, cake house to show cake, soft drink, food etc..
It has handsome appearance quality material, vacuum movable door, transparent
glass and inner light. Cooling system adopted famous brand of whole close
cooling compressor and all kinds of spare parts.
Therefore, the product has the strongpoint of handsome appearance, rational
design, quick cooling, electric saving, low noise, no frost and suitable
temperature.
Main technical data
Model| Net Volume| Temperature| Voltage/ Frequency| Input power| Refrigerant/
Injected Rate| Dimension| N.W
---|---|---|---|---|---|---|---
KTH9713R| 380L| 2-10℃|
220-240V/ 50Hz
| 0.400kw| R290/65g| 9007401300mm| 150kg
KTH12713R| 505L| 0.445kw| R290/95g| 12007401300mm| 180kg
KTH15713R| 635L| 0.515kw| R290/145g| 15007401300mm| 210kg
KTH18713R| 780L| 0.560kw| R290/149g| 18007401300mm| ×××
Safety attention
- You must use single-phase three poles power socket, its grounding E must be grounded reliably.
- Forbid stocking volatile, erosive, radioactive, flammable, explosive, poisonous and polluted dangerous food.
- Please don’t put power wire on aisle to prevent heaving pressure and edge tool from creepage accident.
- Don’t wash the showcase by water to prevent from short circuit and creepage accident.
- Please cut off power socket when repairing or replacing light.
Operation attention
- Please put the showcase lightly when moving and gradient isn’t more than 45°.
- Please put it in ventilated and dry place and be away from heat source and dust to prevent from affecting cooling effect.
- If the socket don’t have grounding device, please make the hull ground to prevent from creepage accident.
- The power capacity shouldn’t be less than 200V, please check circuitry and capacity before operation. If the power isn’t coherent with power requirement, please add ministate whose capacity is more than 1000W before reusing.
- The thermostat has been adjusted to best place before out of factory. You shouldn’t adjust it.
- The time between turn off and turn on again can’t be less than 3 minutes.
- Please don’t put too much or overshot food.
- Please assure the inner and surface of showcase is clean.
- It has water plate, you should get rid of the water in the plate periodically.
Maintenance
- If found special situation, please don’t dismantle parts and should invite professional technician.
- The time between turn off and turn on again should be more than 3 minutes.
- Please get rid of dust and oil pollution periodically to improve cooling effect.
- If you stop operating the showcase for a long time, you should cut off power, make it clean and put it in dry and ventilated place. Please check the electrical wire strictly by technician before operation again.
Familiar trouble and salvation
Phenomena | Possible reason | Check content | Solvation |
---|---|---|---|
Indicator doesn’t work | Compressor doesn’t work | Power has no electric | Check |
by multimeter | Connect power | ||
Socket is loose | examine | Tight socket | |
Thermostat foot is loose | Check by multimeter | Jointing or tighten it | |
Relay foot is loose | Check dismantled cover | Tighten it | |
Compressor is working | Indicator doesn’t work | Dismantle |
indicator
| Replace indicator
Indicator foot is loose| examine| Tighten foot
Compressor is working| Inner temperature is too high| Evaporator wing is
blocked by ice| Cooling fan doesn’t work| Check by multimeter| Replace fan
Temperature is too low| examine| adjust
Opening door too often| | Opening door as few as possible
Stock is too large| | Take out some food
Environment temperature is too high| Test by temperature meter| Improve
environment temperature
Cooling fan doesn’t work| Cooling fan is bad| Check by
temperature
| Replace fan
Foot is loose| examine| Tighten foot
Inner temperature has been achieved| Thermostat is bad| Check thermostat|
Replace thermostat
High noise| Showcase isn’t put flat| examine| Make flat
Fan/compressor foot is loose| examine| Tighten screw
Guarantee
We are responsible for maintenance for 1 year in the case of operation according to the user’s manual. If the spare parts is bad caused by our bad quality, we are responsible for replace and repairing (expect glass)
You should pay rational fee after repairing the trouble caused by reasons as follows:
- The trouble caused by disobeying requirements on user’s manual.
- The trouble caused by using spare parts by yourself.
- The trouble caused by bad capacity fluctuate value or other natural factor.
WARNING!
It’s forbidden to tear down the machine or replace the component and
refrigeration units by nonprofessional.