Danby DAC120B6WDB-6 Air Conditioner Owner’s Manual
- June 9, 2024
- Danby
Table of Contents
Danby DAC120B6WDB-6 Air Conditioner
Welcome to the Danby family.
- We are proud of our quality products and we believe in dependable service. We suggest that you read this owner’s manual before plugging in your new appliance as it contains important operation information, safety information, troubleshooting, and maintenance tips to ensure the reliability and longevity of your appliance.
- You are entitled to the warranty coverage as described in the owner’s manual provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after fi lling out a product survey, at
www.danby.com/support/product- registration/
- Model Number: ____
- Serial Number : ____
- Date of Purchase: __
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fi ll out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Safety Information
Important
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
| WARNING| Shows that the appliance uses a flammable refrigerant. If the
refrigerant leaks and is exposed to an external ignition source, there is a
risk of fire.
---|---|---
| CAUTION| Shows that the operation manual should be read carefully.
**| CAUTION| Shows that service personnel should be handling this
equipment with reference to the installation manual.
| CAUTION**| Shows that the information is available such as the operating
manual or the installation manual.
CAUTION: RISK OF FIRE Flammable refrigerant used. When maintaining or disposing of the air conditioner, the refrigerant must not be allowed to vent into the open air.
SAFETY PRECAUTIONS
WARNING
-
Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock or fi re.
-
Use only the included accessories and parts and specifi ed tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fi re and injury or property damage.
-
Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the unit.
-
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse of circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the unit), have a qualifi ed electrician install the proper receptacle.
-
Install the unit on a fl at, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
-
The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
-
Do not modify the length of the power cord or use an extension cord to power the unit.
-
Do not share a single outlet with other electrical appliances. Improper power supply can cause fi re or electrical shock.
-
Do not install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
-
Do not install the unit in a location that may be exposed to combustible gas as this could cause fi re.
-
The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects as this could cause tipping.
-
Do not operate a unit that been dropped or damaged.
-
The appliance with the electric heater shall have at least 1 meter space from combustible materials.
-
Do not touch the unit with wet or damp hands or when barefoot.
-
If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged contact a technician or customer service for assistance.
-
In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
-
Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store you air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately if this occurs.
-
All wiring must be performed strictly in accordance with the wiring diagram location inside the unit.
-
The units circuit board (PCB) is designed with a fuse to provide over current protection. The
specifications of the fuse are printed on the circuit board. -
When the water drainage function is not in use keep the upper and lower drain plugs fi rmly installed in the unit. The drain plugs can be a choking hazard to children.
CAUTION
- This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Children must be supervised around the unit at all times.
- If the power supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the power supply.
- Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cords away from traffi c and where it will not be tripped over.
- Do not operate a unit with a damaged power cord, plug, power fuse or circuit breaker. Discard the unit or return to an authorized service facility for examination and/or repair.
- To reduce the risk of fi re or electric shock do not use this air conditioner with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the authorized service technician for repair or maintenance of this unit.
- Contact the authorized service installer for installation of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smells or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fi ngers.
- Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
- Do not operate or stop the unit by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of infl ammable substances or vapour such as alcohol, insecticides, petrol, etc.
- Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
- Always contact a qualifi ed person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when removing it.
- Turn off the appliance when not in use.
Note about fluorinated gasses
- Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specifi c information on the type, the amount and the C02 equivalent in tonnes of the fl uorinated greenhouse gas on some models. Please refer to the relevant label on the unit itself.
- Installation, service, maintenance and repair of this unit must be performed by a certifi ed technician.
- Product installation and recycling must be performed by a certifi ed technician.
WARNING for using R32 refrigerant
-
Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer.
-
The appliance shall be stored in a room without continuously operating ignition sources for example, open fl ames, an operating gas appliance or an operating electric heater.
-
Do not pierce or burn.
-
Be aware that the refrigerants may not contain an odor.
-
The appliance should be installed, operated and stored in a room with a fl oor area according to the amount of refrigerant to be charged. For specifi c information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the label and the manual on the minimum room area description, the description on the label shall prevail.
-
Compliance with national gas regulations shall be observed.
-
Keep ventilation openings clear of obstruction.
-
The appliance shall be stored so as to prevent mechanical damage from occurring.
-
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specifi ed for operation.
-
Any person involved with working on the refrigerant circuit should hold a current, valid certifi cate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specifi cation.
-
Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of fl ammable refrigerants.
-
Please follow the instruction carefully to handle, install, clear and service the air conditioner to
avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should not be allowed to discharge to the air directly. -
No open fi re or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the fl ammable refrigerant used.
-
Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
-
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard. For specifi c information on the type of gas and the amount, please to the relevant label on the unit itself.
-
The appliance shall be stored in a room without continuously operating open fl ames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
-
Transport of equipment containing flammable refrigerants: See transport regulations.
-
Marking of equipment using signs: See local regulations.
-
Disposal of equipment using flammable refrigerants: See national regulations.
-
Storage of equipment/appliances : The storage of equipment should be in accordance with the manufacturer’s instructions.
-
Storage of packed (unsold) equipment: Storage package protection should be constructed such that the mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
Information on servicing
- Checks to the area: Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
- Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a fl ammable gas or vapour being present while the work is being performed.
- General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confi ned spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all fl ammable material.
- Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially fl ammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with fl ammable refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.
- Presence of fireextinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry powder or C02 fi re extinguisher adjacent to the work area.
- No ignition sources : No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained fl ammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fi re or explosion. All possible ignition sources including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding space. Before work taking place, the area around the equipment is to be surveyed to make sure there are no fl ammable hazards or ignition risks. No smoking signs shall be displayed.
- Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferable expel it externally into the atmosphere.
- Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fi t for the purpose and to the correct specifi cation. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using fl ammable refrigerants:
- The charge size is in accordance with the room size within which the refrigerant containing parts are installed.
- The ventilation machinery and outlets are operating adequately and are not obstructed.
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
- Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
- Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitable protected against being corroded.
- Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include:
- That capacitors are discharged. This shall be done in a safe manner to avoid possibility of sparking.
- That no live electrical components and wiring are exposed while charging, recovering or purging the system.
- That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- To ensure that by working on electrical components the casing is not altered in such a way that the level of protection is affected, particular attention shall be paid to the following:
- Damage to cables, excessive number of connections, terminals not made to original specifi cation, damage to seals, incorrect fi tting of glands, etc.
- Ensure the apparatus is mounted securely.
- Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of fl ammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifi cations.
- Note: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
Repair to intrinsically safe components
- Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a fl ammable atmosphere.
- The test apparatus shall be at the correct rating. Replace components only with parts specifi ed by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
- Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants
-
Under no circumstances shall potential sources of ignition be used in the search for or detection of refrigerant leaks. A halide torch or any other detector using a naked
flame shall not be used. -
Leak detection methods
-
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants:
-
Electronic leak detectors shall be used to detect fl ammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
-
Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confi rmed.
-
Leak detection fl uids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
-
If a leak is suspected, all naked fl ames shall be removed or extinguished.
-
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
Removal and evacuation
- When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that the best practice is followed since fl ammability is a consideration. The following procedures shall be adhered to:
- Remove refrigerant.
- Purge the circuit with inert gas.
- Evacuate.
- Purge again with inert gas.
- Open the circuit by cutting or brazing.
- The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
- Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fi ll until the working pressure is achieved, then venting to atmosphere and fi nally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the fi nal OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place.
- Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
- In addition to conventional charging procedures, the following requirements shall be followed:
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete, if not already labeled.
- Extreme care shall be taken not to overfi ll the refrigeration system.
- Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.
Decommissioning
- Before carrying out this procedure, the technician must be completely familiar with the equipment in all its detail. It is recommended good practice that all refrigerants are recovered safely. Before the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required before re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
- A. Become familiar with the equipment and its operation.
- B. Isolate system electrically.
- C. Before attempting the procedure ensure that:
- Mechanical handling equipment is available if required for handling refrigerant cylinders.
- All personal protective equipment is available and being used correctly.
- The recovery process is supervised at all times by a competent person.
- Recovery equipment and cylinders conform to the appropriate standards.
- D. Pump down refrigerant system, if possible.
- E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- F. Make sure that cylinder is situated on the scales before recovery takes place.
- G. Start the recovery machine and operate in accordance with the manufacturer’s instructions.
- H. Do not overfi ll cylinders. No more than 80% volume liquid charge.
- I. Do not exceed the maximum working pressure of the cylinder, even temporarily.
- J. When the cylinders have been fi lled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
- K. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
- Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains fl ammable refrigerant.
Recovery
-
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
-
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovers cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designed for the recovered refrigerant and labeled for that refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
-
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of fl ammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that is it in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant leak. Consult the manufacturer if in doubt.
-
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder
and the relevant waste transfer note shall be arranged. Do not mix refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that fl ammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the compressor body shall be employed to accelerate this process. -
When oil is drained form a system, it shall be carried out safely.
INSTALLATION INSTRUCTIONS
LOCATION
- This air conditioner is designed for single or double hung windows. Since window designs vary, it may be necessary to make some modifi cations for safe installation. Ensure that the window and frame are structurally sound and free from dry or rotted wood.
- This air conditioner is not designed for vertical, slider type windows or “through the wall” installation.
- Install the air conditioner in a window on a side of the building which favors more shade than sunlight. If the appliance must be in direct sunlight, it is advisable to provide a shade awning over the appliance to ensure effi cient functioning.
- Do not install the appliance where leakage of combustible gas is suspected.
- This appliance is designed to evaporate condensation under normal conditions. Under extremely hot or humid conditions, excess condensation may overfl ow to the outside. The appliance should be installed where condensation cannot drip on pedestrians or neighboring properties.
- Provide suffi cient clearance around the appliance to allow ample air circulation. The rear of the appliance should be outdoors, it should not be in a garage or another room. Keep the appliance away from obstacles and at least 76 cm (30 inches) above the ground. Ensure that curtains and other obstructions do not block air fl ow to the appliance.
REQUIRED TOOLS
- Screwdrivers: Phillips and fl at head.
- Power Drill: 3.2mm (1/8”) diameter drill bit
- Pencil
- Measuring Tape
- Scissors
- Carpenter’s Level
ACCESSORIES
- The following accessories are included with the appliance and should be used during the installation.
- 13 mm (1/2 inch) screws (x7)
- 9.5 mm (3/8 inch) screws (x4) (Factory installed on some models.)
- Safety Lock
- Adhesive foam seal
- Regular foam seal
- “L” shaped mounting bracket (Factory installed on some models.)
- Bracket for wood windows (x2)
- Bracket for vinyl windows (x2)
- Weatherstripping (x5)
- Side curtains (x2)
INSTALLATION
-
Attach the side curtains to the appliance by sliding the curtain frame into the side channel of the cabinet.
-
The curtains are labeled “left” and “right on the frames. This refers to the left and right
sides of the appliance when facing the front of the appliance. -
Cut the regular foam seal to fi t the area of the window sill that the air conditioner will rest on.
-
Place the air conditioner into the window with the “L” shaped mounting bracket positioned in front of the upper sash. The bottom of the cabinet should be positioned on the recessed portion of the window frame. Pull the upper window sash down until it rests just behind the front fl ange of the “L” shaped mounting bracket.
-
Expand the side curtains on each side and secure the top of the frames to the window sash using one 13 mm (1/2”) screw on each side of the “L” shaped mounting bracket.
-
Attach the clamps on the lower part of each curtain to the window sill using one 13 mm (1/2”) screw on each side of the cabinet.
-
Place the adhesive foam seal into the opening between the inside and outside windows and attached the safety lock to the outside window frame using two 13 mm (1/2”) screws.
Check the Tilt Angle
- The air conditioner should be tilted down towards the outside approximately 3° to 4°. This tilt will encourage any condensed water to drain to the outside. If any condensed water leaks to the inside of the house, check the tilt angle and adjust as necessary.
- Measure the tilt angle from the front of the cabinet’s edge.
- The difference in height between the front and the back of the appliance, labeled “A” on the image below, should be approximately 2.5 cm – 3.5 cm (1” – 1 3/8”).
L BRACKET
- The “L” shaped bracket may come factory installed on some models.
- If the “L” shaped bracket is not pre-installed, attach it to the top of the cabinet as shown below using the provided 9.5 mm (3/8”) screws (x4).
OPERATING INSTRUCTIONS
CONTROL PANEL
- Display panel
- Displays the set temperature
- While in fan mode, shows the room temperature
- A. Energy saver mode indicatorEnergy saver mode indicator
- B. Wireless connection indicatorWireless connection indicator
- C. Cool mode indicatorCool mode indicator
- D. Fan mode indicatorFan mode indicator
- E. Temperature and timer display
- F. Temperature scale indicatoremperature scale indicator
- G. Filter reset indicatorFilter reset indicator
- Mode button:
- Used to choose the operating mode.
- The filter reset indicator will illuminate after 250 hours of use as a reminder to clean the filater. After cleaning the fi later, press and hold the mode button for 3 seconds to clear the filter reset indicator.
- Increase and decrease buttons:
- Used to adjust the set temperature.
- Press and hold the increase and decrease buttons for 3 seconds to change between °C and °F.
- Power Button: Used to turn the appliance on or off.
FUNCTION INSTRUCTION
Operating Modes
Cool Mode
- Choose cool mode to set the cooling function. Use the up and down arrows to choose the desired temperature. When cool mode is selected, the fan speed can be adjusted by pressing the fan button on the remote control.
- The temperature can be set within a range of 17°C – 30°C (62°F – 86°F).
Fan Mode
- Choose fan mode to run the internal fan without engaging the cooling function. Press the fan button on the remote control repeatedly to choose the fan speed.
REMOTE CONTROL
- Power Button: Used to turn the appliance on or off.
- Mode Button: Used to choose the operating mode.
- Fan Button: Used to set the fan speed.
- Sleep Button: Used to set the sleep function.
- Swing button: Used to set the angle of the louver on the top of the appliance.
- Press once to begin the swing function.
- Press a second time to stop the louver when it has reached the desired angle.
- Energy Saver Button : Used to set the energy saver function.
- LED Button:
- Press to turn the LED back light on or off.
- Press 7 times to activate the wireless connection. Follow the directions on the wireless connection app for more information.
- Timer off button: Press to set the automatic off timer.
- Timer on button: Press to set the automatic on timer.
- Shortcut button: Press to set and activate the short cut function.
- Increase and decrease buttons:
- Used to adjust the set temperature.
- Press and hold the increase and decrease buttons for 3 seconds to change between °C and °F.
- LED display: Shows the set temperature and timer setting.
REMOTE CONTROL BATTERIES
The remote control requires two AAA alkaline batteries (included). Batteries
should be replaced when:
- a) No sound is heard when attempting to program the appliance.
- b) The appliance does not respond to a command issued by the remote control.
Battery replacement:
- Slide the rear cover on the remote in the direction of the arrow.
- Insert two AAA batteries following the same orientation depicted inside the battery chamber (+/-).
- Reinstall the rear cover.
- If the remote control will not be used for extended periods of time, the batteries should be removed.
Notes:
- Protect the remote control from high temperatures, and keep it away from radiation exposure.
- Keep the control panel receiver out of direct sunlight.
- Do not mix old and new batteries.
- Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh,etc) batteries.
- The remote operates within a range of 8 meters (26 ft.) from the receiver located inside the main appliance. Any obstruction between the receiver and remote may cause signal interference, limiting the ability to program the main unit.
REMOTE CONTROL REGULATIONS
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
- If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifi cations not approved by the party responsible for FCC and Industry Canada compliance could void the user’s authority to operate the equipment. This appliance complies with Part 15 of the FCC Rules and license- exempt RSS standards. Operation is subject to the following conditions:
- This device may not cause interference.
- This device must accept any interference received, including interference that may cause undesired operation.
FCC
-
This equipment complies with FCC RF and IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.
-
This equipment should be installed and operated with a minimum distance of 20 cm (8 inches) between the radiator and your body.
This device complies with RSS-247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. -
This device complies with Canadian CAN ICES-003(B)/NMB-003(B)
-
This device contains:
-
FCC ID: 2ADQOMDNA21
-
IC: 12575A-MDNA21
SUPPLIER’S DECLARATION OF CONFORMITY
- 47 CFR § 2.1077 Compliance Information
- Unique Identifi er: Danby, RG57J2(B)/BGCEU1
- Responsible Party U.S. Contact Information:
- Danby Products Inc.
- 1800 Production Drive
- Findlay, OH
- 45840
- Telephone number or internet contact information: Danby.com
- FCC Compliance Statement: This appliance complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
- This device may not cause interference.
- This device must accept any interference received, including interference that may cause undesired operation.
SHORTCUT FUNCTION
The shortcut function is only available on the remote control. It can be used to set a favourite setting.
- Set the appliance to the temperature and fan speed that you would like to set as a favourite.
- Press and hold the shortcut button for 2 seconds.
- Press the shortcut button at any point in future to return to the favourite setting.
- If no favourite is set, pressing the shortcut button will cause the appliance to run in auto mode at 29°C (79°F), with fan speed set to auto.
TIMER FUNCTION
- The timer function is only available on the remote control. It can be used to turn the appliance on or off after a set period of time.
- To set the automatic timer:
- Press the timer on or timer off button depending on whether the appliance should turn on or off after the set period of time.
- Use the timer buttons to select the desired amount of time before the appliance should turn on. The timer buttons will add or subtract time in 30 minute increments up to 10 hours and then in 1 hour increments up to 24 hours.
- Turning the appliance on or off at any time will cancel the timer settings.
ENERGY SAVER FUNCTION
- The energy saver function is only available on the remove control in cool mode. It will automatically cycle the fan on and off when the compressor is not in use to minimize how often the compressor needs to turn on.
- The fan will continue to run for 3 minutes after the compressor turns off. The fan will then cycle on for 2 minutes in 10 minute intervals until the ambient temperature is above the set temperature, at which point the compressor will turn on and cooling will resume.
SLEEP FUNCTION
- The sleep function can be used to conserve energy during sleeping hours.
- When selected, the set temperature will increase by 1°C/2°F every half hour for one full hour. The appliance will hold the new set temperature for 6 hours before automatically returning to normal operation.
- The sleep function can be canceled at any time by pressing the sleep button.
WIRELESS CONNECTION
- This appliance can be controlled with a wireless application on your wireless device.
- Visit https://www.danby.com/support/apps to download the application and learn about its operation.
CARE & MAINTENANCE
AIR FILTER
- Approximately every two weeks, the fi lter indicator light on the control panel will illuminate as a reminder to clean the fi lter.
- The air fi lter is located behind the front intake grill. To remove the air fi lter, grasp the grille on both sides and gently pull it outwards.
- Remove the fi lter by pulling it downwards.
- Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build up from the air fi lter.
- Wash the fi lter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent.
- Rinse the fi lter with clean water and dry thoroughly before reinstalling in the appliance.
- Press the fi lter button on the control panel to resume normal functioning.
- Note: Do not operate the appliance without the air fi lter installed.
ERROR CODES
- If the display panel shows any of the below error codes, unplug the appliance, let it stand for 5-10 minutes and then plug it back in. If the error persists, call for service.
- AS – Ambient temperature sensor error
- ES – Evaporator temperature sensor error
- E4 – Display board communication error
- Lo – Room temperature is lower than 0°C (32°F)
- HI – Room temperature is higher than 37°C (99°F)
CLEANING
- To avoid possible electric shock, ensure that the appliance is unplugged before performing any cleaning or maintenance.
- The outside of the appliance can be wiped clean with a soft cloth or with a lukewarm, damp cloth if necessary.
- Do not use gasoline, benzene, thinner or any other chemicals to clean this appliance as these substances can cause damage to the fi nish and deformation of plastic parts.
- Never pour water directly onto the appliance as this will cause deterioration of electrical components and wiring insulation.
END-OF-SEASON CARE
-
Before removing the appliance from service for the year, operate the appliance on high fan mode for half a day to ensure the inside of the appliance
is dry. This will help avoid the growth of mold or mildew inside the appliance. Ensure the fi lter is clean and dry. Store the appliance covered in a dry location. -
Note: When installing or removing the appliance from the window, ensure that caution is taken to prevent it from falling backward. It is recommended that installation or removal is completed with assistance to prevent injury to persons or damage to property or the appliance.
DISPOSAL
- Check for local regulatory compliance regarding approved and safe disposal of this appliance.
FREQUENTLY ASKED QUESTIONS
Can I leave my air conditioner in place through the winter?
- No, do not leave the air conditioner in the window during the winter.
What is the electrical rating?
- This information can be found on the rating plate located on the side of the unit.
Can I use an extension cord?
- No, an extension cord may not be used.
Is there supposed to be Styrofoam in the unit?
- The Styrofoam that is inside the unit acts as insulation. Do not remove it. Only remove loose packaging.
Why do I hear water in the unit?
- Water is collected during the air conditioning process and will drain out of the unit and onto the ground. This why the unit should be installed on a slight downward tilt towards the outside.
Why is there frost building up in the unit?
- When outdoor temperatures are below 18.3°C
- (65°F) frost may form when the air conditioner is in cooling mode. Switch the air conditioner to fan only mode until the frost melts.
TROUBLESHOOTING
Air conditioner will not operate
- Plug is not fully inserted into the wall outlet.
- Blown fuse or circuit breaker.
Insuffi cient cooling
- Air fi lter is dirty.
- Blocked air fl ow.
- Appliance size is too small for application.
Noise
- Inadequate support in window installation; double check that all screws are tight and the installation is secure.
- The air fi lter is dirty or blocked.
- Gurgling sounds are normal, this is coolant moving inside the appliance.
Water dripping inside
- Appliance is not properly angled to allow water to drain to the outside
Water dripping outside
- On very hot or humid days dripping water from the back of the appliance is normal
Odors
- Usually caused by the formation of mold or mildew on internal wet surfaces.
- Ensure the fi lter is clean.
- Run the air conditioner on fan mode to remove any internal moisture.
LIMITED “IN HOME” WARRANTY
- This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer.
- This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter “Danby”) or by an authorized distributor of Danby, and is non-transferable.
TERMS OF WARRANTY
- Plastic parts are warranted for thirty (30) days from the date of purchase, with no extensions provided.
First 24 months
- During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor’s option, at no charge to the original purchaser.
To obtain service
- Contact the dealer where the unit was purchased, or contact the nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the unit by anyone other than an authorized service depot, all obligations of Danby under this warranty shall be void.
Boundaries of in-home service
- Danby reserves the right to limit the boundaries of “In Home Service” to the proximity of an authorized service depot. Any appliance requiring service outside the limited boundaries of “In Home Service”, will be the consumer’s responsibility to transport at their own expense to the original point of purchase or a service depot for repair. If the appliance is installed in a location that is 100 kilometers (62 miles) more from the nearest service center, it must be delivered to the nearest authorized Danby Service Depot by the purchaser.
- Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser.
- Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.
EXCLUSIONS
- Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by the unit.
GENERAL PROVISIONS
No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:
- Power failure.
- Damage in transit or when moving the appliance.
- Improper power supply such as low voltage, defective house wiring or inadequate fuses.
- Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (ie. extremely high or low room temperature).
- Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
- Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
- Service calls resulting in customer education.
- Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application, including but not limited to: garages, patios, porches or anywhere that is not properly insulated or climate controlled).
- Proof of purchase date will be required for warranty claims; retain bills of sale. In the event that warranty service is required, present the proof of purchase to our authorized service depot.
Warranty Service In Home
- Danby Products Limited
- PO Box 1778, Guelph, Ontario, Canada N1H 6Z9
- Telephone:519-837-0920 FAX: 519-837-0449
- Danby Products Inc.
- PO Box 669, Findlay, Ohio, U.S.A. 45840
- Telephone:419-425-8627 FAX: 419-425-8629
- 1-800-263-2629 04/17
- Danby Products Limited, Guelph, Ontario, Canada N1H 6Z9 Danby Products Inc. Findlay, Ohio, U.S.A. 45840
- www.Danby.com
Documents / Resources
|
Danby DAC120B6WDB-6 Air
Conditioner
[pdf] Owner's Manual
DAC120B6WDB-6 Air Conditioner, DAC120B6WDB-6, Air Conditioner, Conditioner
---|---
References
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
- Customer Support | Danby Canada
- Apps | Danby Canada
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>