westermo PSI-010-FT2G-P8G Industrial Gigabit PoE+ Booster Switch User Guide
- June 9, 2024
- westermo
Table of Contents
- westermo PSI-010-FT2G-P8G Industrial Gigabit PoE+ Booster Switch
- Product Information
- Product Specifications
- Product Usage Instructions
- Installation Instructions
- Product Maintenance
- General Information
- Safety and Regulations
- Safety Information
- SAFETY DURING INSTALLATION
- Care Recommendations
- Product Disposal
- Compliance Information
- Product Description
- Hardware Overview
- Connector Information
- LED Indicators
- Dimensions
- Installation
- Connecting Powered Device (PD)
- Mounting
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
westermo PSI-010-FT2G-P8G Industrial Gigabit PoE+ Booster Switch
Product Information
The Westermo PSI-010-FT2G-P8G Industrial Gigabit PoE+ Booster Switch is a high-performance networking device designed for use in industrial settings. It features 8 PoE+ ports and 2 Gigabit SFP ports, allowing for easy integration into existing networks.
Product Specifications
- Interface Specifications: 8 PoE+ ports, 2 Gigabit SFP ports
- Operating Temperature: -40°C to +75°C
- Power Input: 48V DC
- Dimensions: 57mm x 99mm x 155mm
Product Usage Instructions
Safety and Regulations
Before installation, ensure that you have read the entire user manual and have a complete understanding of the product. Make sure that your application does not exceed the safe operating specifications for the product. Do not open the device when it is energized as there may be hazardous voltage. The power supply wiring must be sufficiently fused and it must be possible to disconnect it manually from the power supply. Only Westermo qualified personnel should replace the internal fuse. When using the product, do not look directly into a fiber optical port or any connected fiber as it is classified as a Class 1 Laser Product and complies with 21 CFR 1040.10 and 1040.11.
Installation Instructions
Follow these steps to install the Westermo PSI-010-FT2G-P8G Industrial Gigabit PoE+ Booster Switch:
- Ensure that the power supply is disconnected before installing the device.
- Mount the device on a DIN-rail or on a flat surface.
- Connect the power supply to the device using a 48V DC power source.
- Connect the Ethernet cables to the PoE+ ports or use the Gigabit SFP ports for fiber connections.
Product Maintenance
Regularly inspect the device for any signs of damage or wear and tear. If any issues are found, contact Westermo qualified personnel for assistance. Do not attempt to repair the device yourself as it may result in further damage or injury.
General Information
Legal Information
The contents of this document are provided “as is”. Except as required by applicable law, no warranties of any kind are made in relation to the accuracy and reliability or contents of this document, either expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at www.westermo.com.
About This Guide
This guide is intended for installation engineers and users of the Westermo
products. It includes information on safety and regulations, a product
description, installation instructions and technical specifications.
Safety and Regulations
Warning Levels
Warning signs are provided to prevent personal injuries and/or damages to the
product. The following levels are used:
Safety Information
Before installation
Read this manual completely and gather all information available on the product. Make sure it is fully understood. Check that your application does not exceed the safe operating specifications for the product.
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and installed into an apparatus cabinet or similar, where access is restricted to service personnel only. Before energising and connecting communication cables to the product, ensure a protective earthing conductor is first connected to the protective earthing terminal (only valid for metallic housings). Westermo recommends a cross-sectional area of at least 4 mm2. If the product does not have a protective earthing terminal, then the DIN-rail must be connected to protective earth. Upon removal of the product, disconnect the product from the power supply and all other communication ports before disconnecting the protective earthing conductor, or the connection to earth via the DINrail.
HAZARDOUS VOLTAGE
Do not open an energised product. Hazardous voltage may occur when connected
to a power supply.
PROTECTIVE FUSE
The power supply wiring must be sufficiently fused. It must be possible to
disconnect manually from the power supply. Ensure compliance to national
installation regulations. Replacing the internal fuse must only be performed
by Westermo qualified personnel.
CLASS 1 LASER PRODUCT
Do not look directly into a fibre optical port or any connected fibre,
although the product is designed to meet the Class 1 Laser regulations and
complies with 21 CFR 1040.10 and 1040.11.
HANDLING OF SFP TRANSCEIVERS
SFP transceivers are supplied with plugs to avoid contamination inside the
optical port. They are very sensitive to dust and dirt. If the fibre optic
cable is disconnected from the product, a protective plug must be used on the
transmitter/receiver. The protective plug must be kept on during
transportation. The fibre optic cable must be handled the same way.
ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damage to internal electronic parts by
discharging your body to a grounding point (e.g. use a wrist strap).
Care Recommendations
Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
- If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.
- If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.
Product Disposal
This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment. By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.
Compliance Information
Agency Approvals and Standards Compliance
Table 2. Agency approvals and standards compliance
Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable EU directives and UK legislations. The full declaration of conformity and other detailed information is available at www.westermo.com/support/product- support.
Figure 2. The European Conformity and the UK Conformity Assessment markings
Product Description
The PSI-010-FT2G-P8G is a high-performance industrial unmanaged Power over Ethernet switch. It combines the plug-and-play nature of an unmanaged device with the capability to supply power to high-power devices over long distances. With 8 copper ports providing up to 30 W PoE power output per port and a total power budget of 240 W, the possibilities for lean and simple installations are vast. Only one cable is required for both connectivity and power. The switch can be connected to a larger network either by copper Gb-Ethernet or by fibre optic transceivers (SFPs). This offers flexibility for installations to reach both short and long distances by using any of the many SFPs in the Westermo portfolio. In addition, it also offers a cost-effective connection with the copper port. A fibre optic connection can be made outside the premises, as there is no electrical connection, allowing for diverse ground potentials. Designed for harsh industrial environments, the switch is able to withstand extreme temperatures, vibrations, humidity, and electrical environments. The use of only industrial grade components contributes to ensure market leading mean time between failure (MTBF), maximized service life and reduced operational and life cycle costs. The device is thoroughly tested by external test institutes to meet a rich selection of EMC, isolation, vibration and shock standards. These standards are all to the highest levels suitable for industrial environments and rail trackside applications.
Available Models
Table 3. List of available models
Hardware Overview
The bottom side of the product includes one 6-pin removable terminal block connector (with 2 power input and 1 relay alarm output) . There is also a protective earth screw to prevent interference.
Figure 4. Location of interface ports, bottom view
Connector Information
Power/Alarm Input
Wiring the Relay Output
The product provides relay output. The relay contacts are energized (open) for
normal operation and will close under faulty condition such as Ethernet port
link break.
Ethernet Connection TX
- Ports 9-10 are Ethernet combo ports, i.e, a port pair with one RJ45 and one SFP port. It is possible to use either the RJ45 port or the SFP port. Only one of the ports in the pair can be active at any given time.
SFP Transceivers
Each SFP slot can hold one SFP transceiver. See “Transceiver User Guide 6100-0000” for transceiver handling instructions, which also can be downloaded from the product support pages at www.westermo.com/support/product- support. In the event of contamination, the optical connectors in the SFP transceivers should only be cleaned by the use of forced nitrogen and some kind of cleaning stick. Recommended cleaning fluids are methyl-, ethyl-, isopropyl- or isobutyl alcohol, hexane or naphtha.
LED Indicators
Table 6. LED indicators
Dimensions
Dimensions are stated in mm.
Installation
Wiring the Power Inputs
The product accepts 12 to 56 VDC power input and boosts to 54 to 56 VDC output
for 802.3af /at standard PoE devices.
- Insert the positive and negative wires of your DC supply into the V+ and V- contacts of the terminal block connect or. The acceptable wire range is 12 AWG.
- Tighten the terminal screws to prevent loose DC wires.
Wiring Protective Earth
To ensure the system will not be damaged by noise or electric shock, make a
direct connection between the product and protective earth to avoid system
damage.
Wiring the Ethernet Ports
The product supports 8 ports with automatic MDI/MDI X crossover, a PoE
Injector, and automatic 10/100 Mbps data rate sensing for 10Base T or 100Base
TX connections. Automatic MDI/MDI X crossover allows you to connect to other
switches, hubs, or workstations, without regard to using straight through or
crossover cabling. Port 1 to 8 also provides PoE function that delivers 54 VDC
power through the spare pairs to power the PD. Connect one side of an Ethernet
cable into any switch port and connect the other side to your attached device.
The green LNK LED will light up when the cable is correctly connected. Refer
to the LED Indicators information for descriptions of each LED indicator.
Always make sure that the cables between the switches and attached devices
(e.g. switch, hub, or workstation) are less than 100 metres (328 feet).
Connecting Powered Device (PD)
Port 1 to 8 provide PoE inject function with maximum 30 W ability. To power up the powered device, use the straight or cross over Ethernet cable. The product follows the IEEE802.3af /at alternative A mode connector assignment. Be sure the twisted pair cable is bound with the standard RJ- 45 pin. If the RJ-45 is bound with the wrong pin number, the product will not recognize the PD and will not forward 54 VDC power to PD.
NOTICE
This product is designed for in building installation only and is not intended
to be connected to exposed (outside plant) networks.
Mounting
This product should be mounted on a 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground.
- Insert the upper end of the DIN-rail clip into the back of the DIN-rail track from its upper side.
- Lightly, push the bottom of the DIN-rail clip into the track.
- Check if the DIN-rail clip is tightly attached to the track.
Specifications
Interface Specifications
- Westermo • Metallverksgatan 6, SE-721 30 Västerås, Sweden
- Tel +46 16 42 80 00 Fax +46 16 42 80 01
- E-mail: info@westermo.com www.westermo.com
6626-2200 REV. A 2023 02 @ Westermo Network Technologies AB, Sweden
References
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>