nJoy PWUP-BP16PBA-AZ01B Balder Battery Pack 2U User Manual
- June 9, 2024
- NJOY
Table of Contents
nJoy PWUP-BP16PBA-AZ01B Balder Battery Pack 2U
Thank you for purchasing our products!
Please read this manual before using the product.
| Focusing on quality at competitive prices, nJoy designs consumer products
for a better and enjoyable way into the digital world.
---|---
The battery pack is a product that works only with an UPS. The battery pack will provide or extend the backup time of your UPS.
Package Contents
✓ Battery pack unit
✓ User manual
✓ Battery connection cable
✓ Warranty card
NOTE: If any of the above package content is missing or is damaged please contact the shop from where you have bought this product
Product Overview
Front View
Back View
- DC connector: connects to either UPS or 2nd battery pack
- DC breaker
• Battery over-current protection breaker
• Easy swap battery: When switching battery, put the position of the breaker in “O” position. In case there is a second (or further) battery pack connected to the battery bank, the DC voltage from the UPS will flow through without any interruption to the following battery bank(s)
Important Safety Warnings
Please read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully!
Preparation
This battery bank is connected to an UPS. There will be voltage at the output
terminals if the UPS is turned on even if the input AC Mains is not available.
Make sure that the AC Utility outlet is correctly grounded.
Do not try to repair the unit yourself, contact your local supplier or your
warranty will be void.
Installation and connection warnings
Use a certified input power cable with the correct plugs and sockets.
To eliminate any overheating of the battery bank, keep all ventilation
openings free from obstruction and do not place any foreign objects on top of
the battery bank. Keep the battery bank 20 cm away from the wall.
Make sure the battery bank is installed within the proper environment as
specified: 0-40°C and 30- 90% non-condensing humidity
Cautions regarding battery installation
Do not install the battery bank under direct sunlight. Your warranty will be
void if the batteries fail due to overheating.
This battery bank is designed for indoor use only.
This battery bank is not designed for use in dusty, corrosive and salty
environment.
Storage and maintanance
The warranty for this battery bank will be void if water or other liquid is
spilt or poured directly onto the battery bank. Similarly, warranty is void if
any damage to the battery bank occurs due to foreign objects which are
deliberately or accidentally inserted into the battery bank enclosure.
The battery will discharge naturally if the system is unused for a period of
time. It should be recharged every 2-3 months if unused. If this is not done,
then the warranty will be void. During normal operation, the batteries will be
automatically charged.
Servicing of batteries should be performed or supervised by trained personnel
only. When replacing batteries, replace with the same quantity, type &
capacity.
The unit contains no user-serviceable parts. If the battery service life has
been exceeded, the batteries must be replaced. In this case, please contact
your dealer.
Other cautions
Do not dispose of batteries in an open fire, they may explode.
Do not open or otherwise damage the batteries. The electrolyte from the
batteries is toxic and harmful to the skin and eyes. Risk of electric shock!
The battery circuit is not isolated from AC, hazardous voltage may exist
between battery terminals and ground. Test before touching with bare hands.
A battery can present a risk of electrical shock and high short circuit
current.
Installation
NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use
Properly install the battery pack into the rack using screws
Rack – mount instalation
Connection of the battery pack
Follow the below installation chart in order to connect with UPS and other battery pack (if applicable) with included cable.
Battery Installation
If your battery pack is not installed with batteries, please follow the proper procedure to put the batteries inside the unit.
NOTE: Make sure that the battery pack is disconnected from the ups before performing the following sequence of operations!
The following precaution should be observed when working on batteries:
- Remove watches, rings, or other metal objects.
- Use tools with insulated handles.
- Wear rubber gloves and boots.
- Do not lay tools or metal parts on top of batteries as you might produce a short.
- Disconnect charging source prior to connecting or disconnecting battery terminals.
- Do not plug or unplug the battery connector if UPS works in DC (discharging) mode.
Install batteries into the pack connecting them serially using the wires inside the unit, as shown on the following diagram:
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with separate collection systems)
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste.
Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural resources.
EU Declaration of Conformity
We, manufacturer / importer
Balder Battery Pack 2U: PWUP-BP16PBA-AZ01B
is in conformity with
(EC conformity marking)
Tested with the listed standards, the above mentioned product was found in compliance with 2004/108/EC EMC Directive and with 2006/95/EC LVD Directive.
Read User Manual Online (PDF format)