nJoy Horus Plus Series LCD Touchscreen Display User Manual
- June 9, 2024
- NJOY
Table of Contents
nJoy Horus Plus Series LCD Touchscreen Display
Before using this product, carefully read all product documentation and retain it for future reference.
Thank you for purchasing our products!
Please read this manual before using the product.
- nJoy is a brand of power and backup protection products that create solutions for multiple levels of environment complexity, residential to industrial.
- This UPS will protect your electronic equipment from physical damage and will provide emergency battery backup power to prevent data loss in the event of power problems.
The following models belong to the Horus Plus Series
- 600VA: Horus Plus 600
- 800VA: Horus Plus 800
- 1000VA: Horus Plus 1000
- 1500VA: Horus Plus 1500
- 2000VA: Horus Plus 2000
Package Contents
- UPS Unit
- User Manual
- USB Cable
- Power Cord
- Warranty Card
Product Overview
Front View
Back View
- Battery backup outlets
- AC input
- Circuit breaker
- RJ-11 surges protection (+RJ45 – Horus Plus 1000, 1500, 2000)
- USB port
Touchscreen LCD Display
NOTE: If backlight shuts off, you may activate it by touching the screen.
Installation
The UPS can protect your equipment from all power problems such as surge, blackouts, brownouts and line noise. When AC power is present and the ON/OFF switch is turned ON, the UPS is always charging the battery and provides power to the equipment from AC line directly. A reliable built-in battery can provide stable power in order for you to complete your work, save your data and safely shut down your system when there is a utility power blackout.
The UPS is simple to operate and install. Please read the following steps before connecting any equipments to this UPS:
Positioning
- For optimal ventilation of the UPS, please place it 15cm distance from any wall or object.
Connecting your equipment and first usage
-
Step 1: Connect the UPS to a grounded AC power outlet.
-
Step 2: Please turn ON the ON/OFF switch and charge the battery at least 6 hours for a full load before you start to use the UPS.
-
Step 3: Plug your PC or peripheral equipment (printer, tv, scanner, fax, speakers, etc.) into the power outlets of the UPS (these will provide emergency battery backup power during blackouts as well as surge protection from surges and spikes). Do not attach powerful sound systems and woofers or non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to the UPS!
-
Step 4: Connect the phone/network/internet cables to the
RJ11/RJ45 outlet. -
Step 5: For optimal computer system protection, install the UPS monitoring software from https://www.power-software-download.com/viewpower.html to fully manage the UPS.
CAUTION
- Do NOT plug LASER PRINTERS into any of the outlets.
- Do NOT plug any SURGE STRIPS into any of the outlets.
General Specifications
Automatic voltage regulation
- Regulates the input voltage and eliminates the problems created by under-voltage or over‑voltage fluctuations. It also protects against spikes and surges that comprise over 80% of power problems.
Auto restart
- The UPS will restart automatically and will start charging the batteries once the electricity is back on.
Cold Start Function
- When the UPS is OFF and there is no connection to the power utility, it’s still possible to start the UPS unit using the remaining battery power.
USB Port
- The built-in USB port connects to your computer, automatically saves your data and shuts down your computer (with the help of the included software) in case of a power failure.
Software
Your personal computer can receive the status of the UPS regarding the utility power line, utility power failure, on battery and low battery by signals that are sent through the USB port with the help of the software on your CD.
Important Safety Warnings
- Place the UPS indoors in an area that has adequate airflow and no excessive dust. Do NOT allow the UPS to be exposed to moisture, rain, excessive heat or direct sunlight.
- The use of the UPS is NOT recommended in life support applications where failure of this equipment can reasonably be expected or when its safety or effectiveness could be affected significally.
- Please always disconnect the input power cord from the wall outlet before replacing the battery.
- Do NOT dispose of the battery in a fire. The battery may explode.
- Do NOT open or damage the battery. It contains an electrolyte that is toxic and harmful to the skin and eyes.
- Proper disposal of the battery is required. Please follow your local laws/regulations regarding battery disposals.
- Use tools with insulated handles to replace the battery to avoid personal injury. Due to energy hazard, please remove wrist watches and hand jewerly when replacing the battery.
Fault Code Table
Troubles and solutions
Problem
|
Possible Cause
|
Solutions
---|---|---
Nothing is displayed on LCD panel.
| The UPS is not switched on.| Press the power switch again to turn on the
UPS.
Battery voltage is too low.| Charge the battery at least 6 hours.
Battery fault.| Replace the battery.
The UPS is always on battery mode.| Power cord loose or no mains power.|
Check mains power and re- plug the power cord.
The UPS continuously beeps.| Please check the fault code for the details.|
Please check the fault code for the details.
Backup time is too short.
| Battery voltage is too low.| Charge the battery at least 6 hours.
Overload.
| Remove some unnecessary loads. Before reconnecting equipment, please verify
that the load matches the UPS capability specified in the specifications.
Battery fault.| Replace the battery.
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with separate collection systems)
- This symbol on the product or on its packaging indicates that this product shall not be treated as household waste.
- Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
- By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
- The recycling of materials will help to conserve natural resources.
EU Declaration of Conformity
We, manufacturer / importer
- DAI-TECH SRL 28 Popa Sapca
- 300057, Timisoara Romania
declare that the products
UPS Horus Plus Series
- PWUP-LI060H1-AZ01B, PWUP-LI080H1-AZ01B, PWUP-LI100H1-AZ01B, PWUP-LI150H1-AZ01B, PWUP-LI200H1-AZ01B
are in conformity with
(EC conformity marking)
Tested with the listed standards, the above mentioned products were found in compliance with 2004/108/EC EMC Directive and with 2006/95/EC LVD Directive.
-
EN 62040 – 2: 2006
-
IEC 61000 – 4 – 2: 2001
-
IEC 61000 – 4 – 3: 2002
-
IEC 6100 – 4 – 4: 2004
-
IEC 6100 – 4 – 5: 2005
IEC 6100 – 2 – 2: 2002 -
EN 62040 – 1 – 1: 2003
-
IEC 60950 – 1: 2001
and in conformity with
(RoHS conformity marking) in accordance with European Directive 2011/65/EU.
May 13, 2016
Timisoara
Date and location
- Tommy Lee