nJoy Token Series USB Charger User Manual

June 9, 2024
NJOY

nJoy Token Series USB Charger User Manual
nJoy Token Series USB Charger

Thank you for purchasing our products!
Please read this manual before using the product.

nJoy is a brand of power and backup protection products that create solutions for multiple levels of environment complexity, residential to industrial

This UPS will protect your electronic equipment from physica damage and will provide emergency battery backup power to prevent data loss in the event of power problems.

The following models belong to the Token Series UPS:

600 VA :Token 600
800 VA :Token 800

Package contents

  • UPS unit
  • Power cord (attached)
  • USB cable
  • User manual
  • Warranty ca

NOTE!
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Keep the original package in a safe place for future use.

Product overview

NOTE!
Points 6 and 7 are for Token 800 model only!

  1. LED indicators (for Token 600 model) / LCD display (for Token 800 model): Indicate status information, settings and events.
  2. Power On/Off button: To turn on the UPS unit, press the power switch lightly. Then, the LED or LCD will light up. To turn off the UPS unit, press the power switch again. Then, display will shut off.1. LED indicators (for Token 600 model) / LCD display (for Token 800 model): Indicate status information, settings and events.
  3. Power On/Off button: To turn on the UPS unit, press the power switch lightly. Then, the LED or LCD will light up. To turn off the UPS unit, press the power switch again. Then, display will shut off.
  4. Battery backup outlets: These outlets provide battery backup, EMI filtering, line conditioning, and surge protection. Battery power is automatically provided in case of power failure.
  5. Surge-protected outlets: These outlets do not provide power during power failure.
  6. HID USB port: Allows the UPS to appear in Windows like a battery icon. When the power is out, you can still see the battery level and adjust its settings. Also Windows power management options are available. In case you need more advanced local management we recommend you to install and use “ViewPower” software.
  7. Network, Modem or Phone surge protection: (only for Token 800 model) This UPS protects a single line (1 in/1 out) phone, modem, or fax machine from surges when connected through the UPS.
  8. USB charger port: 5VDC, 2.1A (only for Token 800 model)
  9. AC input power cord: Connect to utility power.
  10. Input circuit breaker: The circuit breaker provides optimal overload protection.

Important safety warnings

Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and carefully read the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully:

Transportation

  • Please transport the UPS system only in the original package to protect against shock and impact.

Preparation

  • Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be absolutely dry before being installed. Please allow at least two hours for the UPS system to acclimate to the environment.
  • Do not install the UPS system near water or in moist environments.
  • Do not install the UPS system where it would be exposed to direct sunlight or near heat sources.
  • Do not block ventilation holes in the UPS housing.

Installation

  • Do not connect appliances or devices which would overload the UPS system (e.g. laser printers) to the UPS output sockets.
  • Place cables in such a way that no one can step on or trip over them.
  • Do not connect domestic appliances such as hair dryers to UPS output sockets.
  • The UPS can be operated by any individuals with no previous experience.
  • Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system.
  • Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your computer) to connect the UPS system to the building wiring outlet (shockproof outlet).
  • Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS system.
  • When installing the equipment, it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3.5mA.

Operation

  • Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) during operations since this would cancel the protective earthing of the UPS system and of all connected loads.
  • The UPS system features its own, internal current source (batteries). The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet.
  • In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect the mains.
  • Prevent fluids or other foreign objects from entering the inside of the UPS system.
  • WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.

Maintenance, service and faults

  • The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. Caution – risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.
  • Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor  such as BUS-capacitors.
  • Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries.
  • Caution – risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Before touching, please verify that no voltage is present!
  • Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified in this manual and any other measures necessary when working with batteries: remove wristwatches, rings and other metal objects, use only tools with insulated grips and handles.
  • When changing batteries, install the same number and same type of batteries.
  • Do not attempt to dispose of batteries by burning them. This could cause battery explosion.
  • Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic.
  • Please replace the fuse only with the same type and amperage in order to avoid fire hazards.
  • Do not dismantle the UPS system.

Installing your UPS system

Hardware installation guide

  1. Placement & Storage conditions
    Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature and humidity is outside the specific limits. (Please check the specs for the limitations.)

  2. Connect to utility and charging
    Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 6 hours before initial use. The unit charges its battery while connecting to the utility.

  3. Connect the loads
    Plug in the loads to output receptacles on the front panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
    CAUTION
    Due to its high-power consumption, we do NOT recommend connecting LASER PRINTERS or loudspeaker equipment such as SUBWOOFERS to this type of UPS.
    Do NOT plug any SURGE STRIPS into any of the outlets

  4. Connect communication cable
    To allow for unattended UPS shutdown/start up and status monitoring, connect the communication cable one end to the USB port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start up and monitor UPS status through PC.

  5. Connect Modem/Phone /Network for surge protection
    Connect a single modem/phone line into surge protected “IN” outlet on the side panel of the UPS unit. Connect from “OUT” out let to the computer with phone line cable.

  6. Turn On/Off the unit
    Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch.

Software installation guide

Install software: For optimal computer system protection, install the UPS monitoring software from https://www.power-software- download.com/viewpower.html to fully manage the UPS.

Positioning

  • For optimal ventilation of the UPS, please place it 15cm distance from any wall or object.

Positioning

Indicators

LED indicators (for Token 600 model)
LED indicators

LED Alarm UPS Status
Green (LED on) Of The mains is normal and UPS is operated normally
Yellow (LED flashing) Sounding every 10 seconds Power failure occurs and UPS

is on battery mode.
Yellow (LED flashing)| Sounding every second| Low battery
Green (LED off)| Of| UPS is off.
Red (LED on)| Continuously sounding| UPS fault

LCD display indicators (for Token 800 model)

UPS Mode LCD display Description
UPS Power on When UPS is powered on, it will enter this mode for few

seconds.
Standby Mo| | In standby mode, no output power is available
AC Mode|
When AVR is functioning, icon will flash every second.| When the input voltage is within acceptable range, UPS will provide stable AC power to output. The UPS will also charge the batteries in AC mode.
Overload in AC mode| LCD display| When overload occurs, alarm will beep every 0.5 secon
Battery Mode| LCD display

When battery level is low, icon will flash every second .

| Alarm will beep every 10 seco
Self-Test Mode| LCD display| This function is only activated via software for the model with communication port.
Battery replacement alarm| LCD display| Alarm will beep every 2 seconds. Only available for the model with communication function.
Overload in battery mode| LCD display| When overload occurs, alarm will beep every 0.5 second.
Fault mode| LCD display| A fault occurs in the UPS. Alarm will continue beeping.

Troubleshooting

Problem Possible cause Solutions
No LCD display on the front pane Low battery. Charge the UPS at least 6

hours.
Battery fault.| Replace the battery with the same type of battery
The UPS is not turned o|
Alarm continuously sounds when the mains is normal.| The UPS is overload.| Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs.
When power fails, back up time is shorten.| The UPS is overload.| Remove some critical load
Battery voltage is too low.| Charge the UPS at least 6 hours.
Battery defect. It might be due to high temperature operation environment, or improper operation to battery| Replace the battery with the same type of battery
The mains is normal, but the unit is on battery mode.| Power cord is loose.| Reconnect the power cord properly.

NOTE!
If any abnormal situations occur that are not listed above, please call for service immediately.

Disposal of Old Electrical & Electronic Equipment

(Applicable in the European Union and other European countries with separate collection systems)

This symbol on the product or on its packaging indicates that this product shall not be  treated as household waste.

Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.

The recycling of materials will help to conserve natural resources.

EU Declaration of Conformity

We, manufacturer / importer
DAI-TECH SRL
28 Popa Sapca
300057, Timisoara
Romania

declare that the products

UPS Token Series:
UPCSBLS660TTOAZ01B
UPCSBLS680TTOAZ01B

are in conformity with

(EC conformity marking)

Tested with the listed standards, the above mentioned products were found in compliance with 2014/30/EU EMC Directive and with 2014/35/EU LVD Directive.

EN 62040-2:2006+AC:2006
EN 61000-3-2:2014
EN 61000-4-3:2006+A2:2010
EN 61000-3-3:2013
EN 62040-1:2008+A1:2013

and in conformity with
(RoHS conformity marking) in accordance with European Directive 2011/65/EU.

May 25, 2020
Timişoara
Stamp Date and location

Tommy Lee

Signature and name

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals