nJoy UPCMTLS665TCAAZ01B Cadu Series Ultra Fast Charger User Manual
- June 9, 2024
- NJOY
Table of Contents
nJoy UPCMTLS665TCAAZ01B Cadu Series Ultra Fast Charger
Before using this product, carefully read all product documentation and retain it for future reference.
Thank you for purchasing our products!
Please read this manual before using the product.
- nJoy is a brand of power and backup protection products that create solutions for multiple levels of environment complexity, residential to industrial
- This UPS will protect your electronic equipment from physical damage and will provide emergency battery backup power to prevent data loss in the event of power problems.
- The following models belong to the Cadu Series UPS:
- 600 VA Cadu 650
- 800 VA Cadu 850
- 1000 VA Cadu 1000
- 1500 VA Cadu 1500
- 2000 VA Cadu 2000
Package contents
- UPS unit
- Power cord
- USB cable
- User manual
- Warranty card
Product overview
NOTE!
Before installation, please inspect the unit. Be sure that nothing inside the
package is damaged. Keep the original package in a safe place for future use
.
- LCD display: Indicate status information, settings and events. It auto-dims to 20% brightness after 20 seconds in normal conditions. It brightens up when power button is shortly pressed or when abnormal condition occurs ( Battery mode, Fault & Alarm).
- Power On/Off button: Short press Power button for LCD brighten, long press Power button to turn the UPS ON or OFF.
- Input power cord: Connect to utility power.
- HID USB port: Allows the UPS to appear in Windows like a battery icon. When the power is out, you can still see the battery level and adjust its settings. Also Windows power management options are available. In case you need more advanced local management we recommend you to install and use “ViewPower” software.
- 1Gb/s Network, Modem or Phone surge protection
- Input circuit breaker: This provides optimal overload protection.
- AC outlet: The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes.
Important safety warnings
Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and carefully read the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully:
Transportation
- Please transport the UPS system only in the original package to protect against shock and impact.
Preparation
- Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS system must be absolutely dry before being installed. Please allow at least two hours for the UPS system to acclimate to the environment.
- Do not install the UPS system near water or in moist environments.
- Do not install the UPS system where it would be exposed to direct sunlight or near heat sources.
- Do not block ventilation holes in the UPS housing.
Installation
- Do not connect appliances or devices which would overload the UPS system (e.g. laser printers) to the UPS output sockets.
- lace cables in such a way that no one can step on or trip over them.
- Do not connect domestic appliances such as hair dryers to UPS output sockets.
- The UPS can be operated by any individuals with no previous experience.
- Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to the UPS system.
- Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your computer) to connect the UPS system to the building wiring outlet (shockproof outlet).
- Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS system.
- When installing the equipment, it should ensure that the sum of the leakage current of the UPS and the connected devices does not exceed 3.5mA.
Operation
- Do not disconnect the mains cable on the UPS system or the building wiring outlet (shockproof socket outlet) during operations since this would cancel the protective earthing of the UPS system and of all connected loads.
- The UPS system features its own, internal current source (batteries). The UPS output sockets or output terminals block may be electrically live even if the UPS system is not connected to the building wiring outlet.
- In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect the mains.
- Prevent fluids or other foreign objects from entering the inside of the UPS system.
- WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.
Maintenance, service and faults
- The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel.
- Caution – risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.
- Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high-capability capacitor such as BUS capacitors.
- Only persons are adequately familiar with batteries and with the required precautionary measures may replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries.
- Caution – risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages may occur between the battery terminals and the ground. Before touching, please verify that no voltage is present!
- Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary measures specified in this manual and any other measures necessary when working with batteries: remove wristwatches, rings and other metal objects, use only tools with insulated grips and handles.
- When changing batteries, install the same number and same type of batteries.
- Do not attempt to dispose of batteries by burning them. This could cause a battery explosion.
- Do not open or destroy batteries. Escaping electrolytes can cause injury to the skin and eyes. It may be toxic.
- Please replace the fuse only with the same type and amperage in order to avoid fire hazards.
- Do not dismantle the UPS system.
Installing your UPS system
Hardware installation guide
-
Placement & Storage conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please place the UPS away from other units at least 15 cm to avoid interference. Do NOT operate the UPS where the temperature and humidity is outside the specific limits. (Please check the specs for the limitations.)
-
Connect to utility and charging
Plug in the AC input cord to the wall outlet. For the best results, suggest to charge the battery at least 6 hours before initial use. The unit charges its battery while connecting to the utility. -
Connect the loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be protected by UPS unit.
CAUTION
- Do NOT plug LASER PRINTERS into any of the outlets.
- Do NOT plug any SURGE STRIPS into any of the outlets.
-
Connect communication cable
To allow for unattended UPS shutdown/start up and status monitoring, connect the communication cable one end to the USB port and the other to the communication port of your PC. With the monitoring software installed, you can schedule UPS shutdown/start up and monitor UPS status through PC. -
Connect Modem/Phone /Network for surge protection
Connect a single modem/phone line into surge protected “IN” outlet on the back panel of the UPS unit. Connect from “OUT” out let to the computer with phone line cable. -
Turn On/Off the unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch. -
Software installation guide
Install software: For optimal computer system protection, install the UPS monitoring software from https://www.power-software-download.com/ viewpower.html to fully manage the UPS.
LCD display indicators
Troubleshooting
Problem | Possible cause | Solutions |
---|
No LCD
display on the
front panel.
| Low battery.| Charge the UPS at least 6
hours.
Battery fault.| Replace the battery with the same type of battery.
The UPS is not
turned on.
| Press the power switch
again to turn on the UPS.
Alarm continuously sounds when the mains is normal.|
The UPS is overload.
| Remove some loads first. Before reconnecting equipment, please verify that the load matches the UPS capability specified in the specs.
When power fails, back
up time is shorten.
| The UPS is overload.| Remove some critical load.
Battery voltage is too low.| Charge the UPS at least 6
hours.
Battery defect. It might be due to high temperature operation environment, or improper operation to battery.|
Replace the battery with the same type of battery.
The mains is normal, but the unit is on battery mode.|
Power cord is loose.
|
Reconnect the power cord properly.
NOTE!
If any abnormal situations occur that are not listed above, please call for
service immediately.
Disposal of Old Electrical & Electronic Equipment
(Applicable in the European Union and other European countries with separate
collection systems) This symbol on the product or on its packaging indicates
that this product shall not be treated as household waste. Instead it shall be
handed over to the applicable collection point for the recycling of electrical
and electronic equipment. By ensuring this product is disposed of correctly,
you will help prevent potential negative consequences for the environment and
human health, which could otherwise be caused by inappropriate waste handling
of this product. The recycling of materials will help to conserve natural
resources.