CNC4PC C92 Modbus Server User Manual

June 9, 2024
CNC4PC

CNC4PC C92 Modbus Server

CNC4PC-C92-Modbus-Server-fig- \(2\)

OVERVIEW

This card provides you with a serious Modbus or TCP / IP connection and has 3 configurable ports for TTL outputs and an analog port

FEATURES

  • MODBUS TCP/IP and USB protocol.
  • Pins 2-9 on IDC26 can be bi-directional, determined by the internal configuration. Presentation Screen LCD
  • It can be powered with a voltage +5vc or IDC26 PIN or from the USB connector. Compatible with CNC controller board.
  • 3 Expansion Ports. It has 3 x IDC26 connector for additional Breakout or Relay Boards.
  • IDC 8pin male for analog input
  • Visualization of the state of the pins on the display with TCP / IP
  • IP configurable
  • Display and encoder for configuration
  • Din rail mountable

DESCRIPTION

CNC4PC-C92-Modbus-Server-fig- \(3\)

TERMINAL POWER

Regulated 5VDC @0.5A is required to power this board
WARNING : Check the polarity and voltage of the external power source and connect the 5VDC and GND. Overvoltage or reverse-polarity power applied to these terminals can cause damage to the board, and/or the power source

MODBUS COMMUNICATION PROTOCOL

USB Communications

For Modbus RTU (Remote Terminal Unit) mode communications the default parameters are the following:

  • Baud Rate = 38,400bps

  • Data Bits = 8

  • Parity = None

  • Stop Bits = 1

  • Flow Control = None

CNC4PC-C92-Modbus-Server-fig- \(5\)

Configuring the control software

To configure use the following sample configuration screen:CNC4PC-C92
-Modbus-Server-fig- \(6\)

TCP/IP Communications
For Modbus TCP mode communications the default parameters are the following:

  • IP address = Configurable in Board C92
  • Port number = 502

Configuring the control software

To configure use the following sample configuration screenCNC4PC-C92-Modbus-
Server-fig- \(7\)

Board Modbus addresses

Analog, Input and output pin discrete.

FUNCTION NAME FUNCTION TYPE
DISCRETE OUTPUT Write SingleCoils
ANALOG INPUT Read InputRegisters
DISCRETE INPUT Read Inputs

PINOUT

PORT_1CNC4PC-C92-Modbus-Server-fig- \(8\)

IDC26 Pin number ADDRESS MODBUS
1 100 OUT
2 104 IN/OUT
3 105 IN/OUT
4 106 IN/OUT
5 107 IN/OUT
6 108 IN/OUT
7 109 IN/OUT
8 110 IN/OUT
9 111 IN/OUT
10 112 IN
11 113 IN
12 114 IN
13 115 IN
14 101 OUT
15 116 IN
16 102 OUT
17 103 OUT
18 – 25 GND
26 +5VDC

PORT_2

IDC26 Pin number ADDRESS MODBUS
1 200 OUT
2 204 IN/OUT
3 205 IN/OUT
4 206 IN/OUT
5 207 IN/OUT
6 208 IN/OUT
7 209 IN/OUT
8 210 IN/OUT
9 211 IN/OUT
10 212 IN
11 213 IN
12 214 IN
13 215 IN
14 201 OUT
15 216 IN
16 202 OUT
17 203 OUT
18 – 25 GND
26 +5VDC

PORT_3

IDC26 Pin number ADDRESS MODBUS
1 300 OUT
2 304 IN/OUT
3 305 IN/OUT
4 306 IN/OUT
5 307 IN/OUT
6 308 IN/OUT
7 309 IN/OUT
8 310 IN/OUT
9 311 IN/OUT
10 312 IN
11 313 IN
12 314 IN
13 315 IN
14 301 OUT
15 316 IN
16 302 OUT
17 303 OUT
18 – 25 GND
26 +5VDC

PORT ANALOG INPUT

IDC8 Pin number ADDRESS MODBUS
1 400
2 401
3 402
4 403
5 404
6 405
7 406
8 407

CONFIGURE MENU

CNC4PC-C92-Modbus-Server-fig-
\(12\)

DIMENSION

CNC4PC-C92-Modbus-Server-fig- \(13\)

All dimensions are in millimeters Fixing hole (3mm).

Disclaimer:
Use caution. CNC machines can be dangerous machines. Neither DUNCAN USA, LLC nor Arturo Duncan are liable for any accidents resulting from the improper use of these devices. This product is not a fail-safe device and it should not be used in life support systems or in other devices where its failure or possible erratic operation could cause property damage, bodily injury or loss of life.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals