CNC4PC THC1 Torch Height Control User Manual
- June 9, 2024
- CNC4PC
Table of Contents
THC1 Torch Height Control
User Manual
OVERVIEW
This module allows you to control the height the plasma torch head relative to work piece during plasma CNC operation, it supports either raw torch head voltage or an input of 0-10VDC, the ARC OK, UP and DOWN outputs are isolated.
FEATURES
- Optoisolated output working at 5 to 24VDC or open collector
- Built-in Voltage Divider for connecting to the voltage on the torch or can use the 010VDC from a voltage divider from the plasma.
- LCD Screen
- 10 to 30VDC Terminal power
- Isolated powered
- Din rail mountable.
- Divider input (16:1 – 20:1 – 40:1 – 50:1 – 1:1) New*
DESCRIPTION
TERMINAL BOARD
4.1 POWER
Requires a 10 to 30VDC at 100mA Power Supply, “This board is electrically
isolated through a DC-DC converter.” WARNING: Check the polarity and
voltage of the external power source and connect the 10VDC to 30VDC and GND.
Overvoltage or reverse-polarity power applied to these terminals can cause
damage to the board, and/or the power source.
4.2 TORCH VOLTAGE
4.3 DIVIDER INPUT (16:1 – 20:1 – 40:1 – 50:1 – 1:1)
4.4 OUTPUT SIGNALS
Voltage applied can be from 5 to 80VDC@50mA, outputs signal opt isolated Open
Collector.
CONFIGURE MENU
Push the knob to enter configuration mode.
Navigate through the configuration menu by pressing the knob. Turn the knob to
adjust the value.
Push the knob to set the value and navigate to the next parameter or until you
reach the run mode.
DESCRIPTION SCREEN
6.1 SET POINT (SP)
SP is the target voltage to be achieved. 6.2 VOLTAGE ARC (ARC)
Limit from 40 to 400VDC, True Voltage measured at the terminals or the voltage
divider. 6.3 HYSTERESIS (HYS)
Is the tolerance or (+/-) voltage range used to generate an adjustment. The
torch height is not commanded to adjust if the true voltage is inside the
specified range. It can be between 2 to 32VDC. 6.4 DELAY TIME (DT)
Torch motion starts the number of seconds you set as DT after the ARC signal
is determined. This can be a value between 0.1 to 9.9 seconds. 6.4 TEST MODE
(TEST)
Press the knob three times to enter test mode.
Turn the knob up or down to make the spindle move.
To exit test mode, press the knob once.
WIRING SAMPLE
Note This wiring is just to illustrate a sample product application. Specific wiring may vary from system to system. It is the users responsibility to implement it correctly.
http://www.cnc4pc.com
Designed : HVM i Date : APRIL-20-2022
Revised : KPG| Date :
Item : WS_260| Ver. : 2
Description : Wiring sample for THC1 with C82
Disclaimer:
Use caution. CNC machines can be dangerous machines. Neither DUNCAN USA, LLC
nor Arturo Duncan is liable for any accidents resulting from the improper use
of these devices. This product is not a fail-safe device and it should not be
used in life support systems or in other devices where its failure or possible
erratic operation could cause property damage, bodily injury or loss of life.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>