Radisys PM4264S GPON GPON Home Gateway User Guide
- June 9, 2024
- Radisys
Table of Contents
Radisys PM4264S GPON GPON Home Gateway
Product Overview
The GPON Home Gateway Unit (HGU) is an ITU-T G.984 ONT designed for delivery of telephone services, IP-base data services, and IPTV video services to single-family homes and small office/home office (SOHO) users. It is designed for indoor installaon and can be desktop or wall-mounted. A single opcal fiber carries upstream and downstream traffic over GPON between the OLT and the ONT and it is fully provisioned and managed from the OLT using PLOAM/OMCI and TR069.
Package contents
- PM4264S
- Fiber Cable
- Power Adapter
- QIG (Quick Guide)
Specification
Device Parameters
SPI FLASH| 128MB| Power Supply| Supply: 110V AC to 240V AC
Adapter: DC 12V/1.5A
---|---|---|---
DDRIII| 256MB (2Gbit)| Power Consumption| < 18 Was (Max)
WiFi| 2.4GHz 2×2 802.11ax
5GHz 2×2 802.11ax| Dimensions ( W D H)| 190mm 154mm 40mm
Port| 1 SC/APC, Class B+ GPON Port
4 10/100/1000Mbps (RJ45) LAN
2 * (RJ11) FXS port| Weight| 516g
Bandwidth| Downstream up to 2.488Gbps Upstream up to 1.244Gbps Max| Opera g
requirement| Temperature :0ºC to +40ºC
Humidity: 5% to 85% Non-condensing
Rear View
Item | Descrip |
---|---|
LAN1~4 | Use Ethernet cables (with RJ45 connectors) to connect home network |
devices
RESET| Press 1~4 seconds The device will reboot (restart).
Press >4 seconds Factory reset is performed by long press
ON/OFF| Click to turn the device on or
WPS/Wi-Fi button| Press 0~5 seconds, execute WPS for both WiFi.
Press >5 seconds, turn on/o Main and Guest WiFi
Front View (LED definition )
LED name | Color | Behavior |
---|---|---|
POWER | Green |
- On – Power on
- Off – No power
GPON| Green|
- Blinking (1 Hz) – GPON physical link available, under GPON ranging (O2 ~ O4, or O7), OLT deactivate ONT
- On – GPON Link State is O5
- Off – No GPON physical link or ONT is in O1 state
AUTH
|
Green
|
- On: Only when the ONT is already configured by the OLT (ready for GPON transmission- More than 2 GEM
- Off: When the ONT is not configured by the OLT.
VOIP| Green|
- Blinking (5Hz) – off-hook / ringing / calling / disconnecting, conversation
- Flashing (1 Hz) – Registering in SIP server
- On: registered correctly on the SIP server
- Off: the SIP agent is disabled or not registered
2G WIFI| Green|
- On – 2G WiFi available
- Off – No 2G WiFi available
5G WIFI| Green|
- On – 5G WiFi available
- No 5G WiFi available
WPS| Green|
- Flashing (1 Hz) – WPS in pairing mode
- Flashing (5 Hz) – When real pairing with WiFi Client
- Off – WPS LED will shut down artier WIFI client connected, WPS not activated
LAN| Green|
- On – Ethernet Link is on
- Off – No Ethernet Link
INTERNET| Green|
- On – Received IP address, HSI connection establishe
- Off – No HSI connection
LOS| Red|
- Red On – Fiber is disconnected or transceiver is disable
- Red Off – Fiber is connected and transceiver is enabled
Web Access
When you turn on the router for the first time (or after resetting it to factory settings), it will start the automatic setting mode. You can connect devices vra wired connection or via the wireless connection.
Wired connection
Step 1. Connect one side of the Ethernet Cable to LAN port and the other
to your computer.
Step 2. Open the browser and enter http:l/192.168.1.254 in URL bar.
Step 3. Enter the username and password specified on the sticker at the
bottom of device.
Wireless connection
Enter SSID and password on product label to connect to WiFi network.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example – use only shielded interface cables when connecting to computer or peripheral devices).
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20
centimeters between the radiator and your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operation. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Complies with FDA performance standards for laser products except for conformance with IEC 60825-1 Ed. 3., as described In Laser Notice No. 56, dated May 8. 2019.
Caution – Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Attention
Manufacturer: Sercomm Headquarters
Address: 8F, No. 3-1, YuanQu St. (Nankang Software Park)
Taipei 115, Taiwan
Documents / Resources
|
Radisys PM4264S GPON GPON Home
Gateway
[pdf] User Guide
GPONHGU, P27GPONHGU, PM4264S GPON GPON Home Gateway, PM4264S, GPON Home
Gateway, Home Gateway, Gateway
---|---