Radisys PM4264S GPON Home Gateway User Guide
- June 1, 2024
- Radisys
Table of Contents
Radisys PM4264S GPON Home Gateway
Specifications
- SPI FLASH: 128MB
- Power Supply: 110V AC to 240V AC
- Adapter: DC 12V/1.5A
- DDRIII: 256MB (2Gbit)
- Power Consumption: < 18 Watts (Max)
- Wireless Specifications:
- 2.4GHz 2×2 802.11ax WiFi
- 5GHz 2×2 802.11ax WiFi
- Dimensions: 190mm154mm40mm (WDH)
- Ports:
- 1 * SC/APC, Class B+ GPON Port
- 4 * 10/100/1000Mbps (RJ45) LAN Port
- 2 * (RJ11) FXS port
- Weight: 516g
- Upstream Speed: up to 1.244Gbps
- Operating Humidity: 5% to 85% Non-condensing
Product Overview
The GPON Home Gateway Unit (HGU) is designed for the delivery of telephone
services, IP-based data services, and IPTV video services to single-family
homes and small office/home office (SOHO) users.
It can be installed indoors and is suitable for desktop or wall-mounted setup.
The device utilizes optical fiber for upstream and downstream traffic over
GPON between the OLT and the ONT and is provisioned and managed from the OLT
using PLOAM/OMCI and TR069 protocols.
Package Contents
(Package contents details are not provided in the extracted text.)
Product Usage Instructions:
Web Access
When setting up the router for the first time or after resetting it to
factory settings, follow these steps:
Wired Connection
- Connect one end of an Ethernet Cable to a LAN port on the device and the other end to your computer.
- Open a web browser and enter “http://192.168.1.254” in the URL bar.
- Enter the username and password specified on the sticker at the bottom of the device.
Wireless Connection
To connect via Wi-Fi, enter the SSID and password found on the product
label.
FAQ
-
Q: What is the default IP address for accessing the device?
A: The default IP address is 192.168.1.254. -
Q: How do I perform a factory reset on the GPON Home Gateway Unit?
A: Pressing the RESET button for more than 4 seconds will initiate a factory reset.
GPON Home Gateway
PM426 4S
Product Overview
The GPON Home Gateway Unit (HGU) is an ITU-T G.984 ONT designed for delivery of telephone services, IP-base data services, and IPTV video services to single-family homes and small office/home office (SOHO) users. It is designed for indoor installation and can be desktop or wall-mounted. A single optical fiber carries upstream and downstream traffic over GPON between the OLT and the ONT and it is fully provisioned and managed from the OLT using PLOAM/OMCI and TR069.
Package contents
- PM4264S
- Power Adapter
- QIG (Quick Guide)
Specification
Device Parameters
Rear View
Front View (LED definition)
Web Access
When you turn on the router for the first time (or after resetting it to factory settings), it will start the automatic setting mode. You can connect devices via wired connection or via the wireless connection.
Wired connection
- Step 1. Connect one side of the Ethernet Cable to LAN port and the other to your computer.
- Step 2. Open the browser and enter http://192.168.1.254 in URL bar.
- Step 3. Enter the username and password specified on the sticker at the bottom of device.
Wireless connection
Enter SSID and password on product label to connect to WiFi network.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example – use only shielded interface cables when connecting to computer or peripheral devices). FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Complies with FDA performance standards for laser products except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.
Caution – Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation exposure
Attention – L’utilisation des commandes ou reglages ou l’execution des
procedures autres que celles specifiees dans les presents exigences peuvent
etre la cause d’une exposition a un rayonnement dangereux
Manufacturer: Sercomm Corporation
Address: 8F, No. 3-1, YuanQu St. (Nankang Software Park) Taipei 115,
Taiwan
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>