Introduction

The Radisys PM6264S XGS-PON Home Gateway Unit (HGU) is an advanced Wi-Fi6 dual-band XGS-PON ONT complying with the ITU-T G.9807.1 standard via SFP+ pluggable interface. The gateway is best suited for FTTH residential and small office use that requires optimal wireless coverage.

Contents

  • PM6264S ONT
  • Quick Installation Guide
  • Power Adaptor
Product Specifications
Interfaces Specification
WAN Uplink PON port (SC/APC)
Ethernet 1 100/1000/10G Base-T port (RJ45) 4 10/100/1000 Base-T ports (RJ45)
Wi-Fi 4×4/4×4 Wi-Fi 6 (internal antennas)
VoIP 2 FXS ports (RJ11)
USB USB 3.0 Type A
Power Adaptor Input 110-240VAC, 50/60Hz
Power Adaptor Output +12VDC nominal, 2A
Operating Temperature 5 to 40°C (41 to 104°F)
Operating Humidity 5 to 85% (non-condensing)
Dimensions 226 x 191 x 46 mm (W x D x H)
Interfaces
Item Description
1 LEDs Status LEDs
2 POWER Power port for external Power Adaptor
3 ON/OFF Button Turn power ON or OFF
4 RESET Reboot ONT (quick push)
Reset to factory (press and hold for 10 seconds)
5 WPS Press to initiate WPS connection
6 Wi-Fi Press to initiate the WPS connection
6 USB USB port for ancillary equipment
7 10GE 10GE Ethernet ports for PC or LAN (RJ45)
8 GE 1-4 1GE Ethernet ports for PC or LAN (RJ45)
9 TEL 1 Phone port for telephony (RJ11)

LED Status Indicators

Label Color Status Definition
POWER White ON Normal operation
Slow blink (1000ms on, 666ms off) Reset to factory defaults, not config-

ured for service
Slow blink (1000ms on, 666ms off)| Initializing, start of boot process
INTERNET| RED| ON| Loss of Signal (LOS) alarm
---|---|---|---
White| ON| Internet service available, IP address
| Slow blink (1000ms on, 666ms off)| Reset to factory defaults, not configured for service
Wi-Fi| White| ON| 2.4GHz/5GHz Wi-Fi radio is enabled with security
| Slow blink (1000ms on, 666ms off)| WPS push-button activated
| Slow blink (1000ms on, 666ms off)| Reset to factory defaults, not configured for service
| OFF| 2.4GHz/5GHz Wi-Fi radio is disabled, WPS is not active
PHONE| White| ON| Telephone port registered for service
| Fast Blink (1000ms off, 280ms on, 280ms off, 280ms on)| Telephone line is off hook
Slow blink (1000ms on, 666ms off)| Reset to factory defaults, not configured for service
OFF| Telephone port is disabled or unregistered

Label Color Status Definition
MOBILE White Fast Blink (1000ms off, 280ms on, 280ms off, 280ms on) Voice

ports in use (VoCS), Incoming Call, Outgoing Call, Call established.
| Slow blink (1000ms on, 666ms off)| Network detected. BACKUP MODE
ON| Data connection established. BACKUP MODE
Red| Slow blink (1000ms on, 666ms off)| Attempting to set up mobile connection. Stick pending PIN or PUK. BACKUP MODE
OFF| 2.4GHz Wi-Fi radio is disabled
5GHZ| Green| ON| 5GHz Wi-Fi radio is enabled
| Slow Blink (1/s)| 5GHz Wi-Fi radio transmitting data

traffic

OFF| 5GHz Wi-Fi radio is disabled
WPS| Green| Slow Blink (1/s)| WPS push-button activated
---|---|---|---
| OFF| WPS is not active
PHONE| Green| ON| Telephone port registered for service
| Slow Blink (1/s)| Telephone line is off hook
OFF| Telephone port is disabled or unregistered
USB| Green| ON| Device is connected to USB port
| OFF| No device connected

Installation

  1. Remove ONT from packaging.
  2. Lay ONT flat on surface or attach ONT to wall.
  3. Remove protection plug (black) from WAN port.
  4. Connect fiber optic cable with SC/APC termination to WAN port.
  5. Connect telephone cable (5) with RJ11 termination to PHONE.
  6. Connect Ethernet cable (6) with RJ45 termination to 10G LAN and LAN 1-4. Recommend CAT6 or better Ethernet cable for 10GE port.
  7. Connect Power Adaptor cable (7) with 2-pin barrel to POWER port.
  8. Plug in Power Adaptor into electrical outlet.
  9. Push ON/OFF button. Check LED power up sequence.

User note: ONT may be upgraded to newer software image prior to provisioning of services. ONT may reset after initial boot up sequence is complete or software image is upgraded.

Mounting ONT on a wall

ONT has two mounting holes that can be used for wall mount placement. Please see diagram for screw separation and location.

ONT should be mounted with LEDs facing up and service interfaces facing down to avoid dust and contamination.

Web Graphical User Interface

You can access the ONT through a web browser using the following steps:

  • Connect an Ethernet cable from your computer to any of the 10G or LAN 1 – 4 ports.
  • Launch a web browser or telnet session and connect to address 192.168.1.1.
  • After response, enter the following:
  1. Username : user
  2. Password: user

After initial login, it is recommended that password be changed.

Caution

Please follow the instructions below to avoid physical injury:

  • This unit is for indoor use only.
  • All Ethernet, telephone and power wiring are limited to inside of the building.
  • You should not install ONG during lighting storms to avoid electrical shock.
  • Never look directly at the fiber port and fiber cable ends when they are powered on.
  • DO NOT plug in, turn on or attempt to operate an obviously damaged unit.
  • DO NOT use near water.
  • DO NOT operate ONT in a location where maximum ambient temp. exceeds 40°C.
  • DO NOT place near high temperature source.
  • Set up the unit away from direct sunlight or other electrical equipment.
  • Open optical connections must use a protective cap under all circumstances to protect against physical damage and dirt.
  • Avoid impact stresses when handling connectors.
  • Physical damage to optical connections impairs transmission quality.
  • Avoid a bend radius in excess of 30 mm for fiber optic links.
  • Check the available voltage supply.
  • Only connect approved accessories.
  • This equipment is not suitable for use in locations where children are to be present.
  • DO NOT disassemble the unit.

Limited Warranty

The product warranty does not cover damage resulting from hardware being installed in areas subject to rain, high humidity, water ingress and dust or debris. Disassembling product or removing enclosure cover from the assembly is a safety hazard and will void warranty. PM6264S may only be repaired by authorized service personnel.

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement

This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF

Rules. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and consider removing the no-collocation statement.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Caution

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Canada Statement

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 25 centimetres between the radiator and your body.

The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals