QSFPTEK S7300-48X2Q4C 48 Port 10G Ethernet L3 Plus Switch User Guide

June 9, 2024
QSFPTEK

QSFPTEK S7300-48X2Q4C 48 Port 10G Ethernet L3 Plus Switch

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
PRO

Introduction

The S7300-48X2Q4C is a high-performance full-10GE ToR switches. The product position is to meet the requirements of next-generation Enterprise, Data Center, Metro, and HCI (Hyper-Converged Infrastructure) networks. The S7300 series switches provide a range of services, such as IPv6, VPN, network security, flow analysis, and virtualization, to offer high-performance L2/L3/L4 wire-speed switching capacity. To ensure maximum uptime, the series employs reliable techniques like continuous forwarding, graceful restarting, and loop network protection, all of which work seamlessly within the S7300 series fabric.

Accessories

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
\(1\)

Hardware Overview

Front Panel Ports

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
\(2\)

No. Ports Description
1, 4 SFP+ Hot-swappable SFP+ ports for 1/10G connection
3 QSFP+ Hot-swappable QSFP+ ports for 40G connection
2 QSFP28 Hot-swappable SFP+ ports for 40/100G connection

Back Panel Ports

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
\(3\)

No. Ports Description
7 CLI An RJ45 console port for serial management
6 MNG An RJ-45 Ethernet management port
5 USB A USB management port for software and configuration backup

and offline software upgrade

Appearance Description for Standard Configuration

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
\(4\)

No. LEDs Name Description
7 PWRA Power indicator A If the power supply A of the switch is

powered on, the indicator is on.
8| PWRB| Power indicator B| If the power supply B of the switch is powered on, the indicator is on.
6| SYS| System indicator| If the system indicator fickers, the system works well. If the indicator is off or always on, the system is abnormally started
9| MNG| Management port indicator| If the indicator is always on, the port is normally linked. If the indicator is not on, the port is not linked. If the indicator is off, the port is not linked. If the indicator flickers, there is data transmisson.
5| LED| Indicator| System/power supply indicators

1, 4

| 1~48(LINK/A CT)| SFP+ port indicators| If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked. If the indicator flickers, there is data transmisson.
3| 40G 1~2| QSFP+ port indicators| 1.   working in the mode of 40GE

If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked.

If the indicator flickers, there is data transmission.

2.   The 40GE port breaks out into 4 10GE ports

The 4 indicators turns on every 5 seconds by turns, which shows the 10GE port state of the BREAKOUT indicator.

2| 40G/100G 1~4| QSFP28 port indicators| 1.   working in the mode of 100GE

If the indicator is always on, the port is normally linked. If the indicator is off, the port is not linked.

If the indicator flickers, there is data transmission.

2.   working in the mode of 40GE

If the indicator is always on, the port is normally lined. If the indicator is off, the port is not linked.

| | | If the indicator flickers, there is data transmission.

3. The 40GE port breaks out into 4 10GEports

The 4 indicators turns on every 5 seconds by turns, which shows the 10GE port state of the BREAKOUT indicator.

---|---|---|---
2| 40GE BREAKOUT (1~4)| The 40GE port breaks out into 4 10GE port indicators.| 1.   Working in the mode of 40GE, the indicator of BREAKOUT is off

2.   The 40GE port breaks out into 4 10GE ports, which combines with QSFP+ port indicators.

If the indicator of QSFP+ is on, the four indicators of 40GE BREAKOUT correspond to LINK/ACT state of the

4 10GE ports of the QSFP+ port

Back Panel

QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch-
\(5\)

Installation Requirements

Tool Preparation:

  • Screwdriver
  • Static armguard
  • Bolt
  • Ethernet cable
  • Other Ethernet terminal devices
  • Control terminal

Tool Preparation:

  • Put off ornaments, such as ring, necklace, watch and bracelet, before you operate under live working. When metal articles connect the power to the ground, short circuit happens and components may be damaged.
  • Pull out the AC power socket and close the direct-current power before operating on the machine box or working beside the power source.
  • When the power is on, do not touch the power.
  • Correctly connect the device and the power socket.
  • Only professionals are allowed to operate and maintain the device.
  • Read the installation guide carefully before the system is powered on.

Site Environment:

  • The switch can be installed on the desk or the cabinet.
  • The location of the machine box, cabinet planning and indoor cabling are very important for normal system’s function.
  • Short distance between devices, bad ventilation and untouchable control plate will cause maintenance problems, systematic faulty and breakdown.

Temperature/Humidity Requirements:

Temperature Humidity
0~45°C 10%~95%

Mounting the switch

Connecting the PowerQSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-
Switch- \(6\)

  1. Plug the AC power cord into the power port on the back of the switch.
  2. Connect the other end of the power cord to an AC power source.

Connecting the SFP+/QSFP+/QSFP28 PortsQSFPTEK-S7300-48X2Q4C-48-Port-10G-
Ethernet-L3-Plus-Switch- \(7\)

  1. Plug a compatible SFP+/QSFP+/QSFP28 transceiver into the SFP+/QSFP+/QSFP28 port.
  2. Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.

Connecting the Management Ports

Connecting the CLI PortQSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3
-Plus-Switch- \(8\)

  1. Insert the RJ45 connector of the console cable into the RJ45 console port on the front of the switch.
  2. Connect the other end of the CLI cable to the RS-232 serial port on the computer.

Connecting the MNG PortQSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3
-Plus-Switch- \(9\)

  1. Connect one end of a standard RJ45 Ethernet cable to a computer.
  2. Connect the other end of the cable to the MNG port on the front of the switch.

Connecting the USB PortQSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3
-Plus-Switch- \(10\)
Insert the Universal Serial Bus (USB) flash disk to the USB port for software and configuration backup and offline software upgrade.

Configuring the Switch

Configuring the Switch Using the Web-based Interface

  1. Step 1: Connect the computer to the Management port of the switch using the network cable.
  2. Step 2: Set the IP address of the computer to 192.168.0.2. Set thesubnet mask of the computer to 255.255.255.0.
  3. Step 3: Open a browser, type http://192.168.0.2, and enter the default username and password, admin/admin.
  4. Step 4: Click sign in to display the web-based configuration page.

Configuring the Switch Using the CLI Port

  1. Step 1: Connect a computer to the switch’s CLI port using the supplied CLI cable.
  2. Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
  3. Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop bit and no flow control.QSFPTEK-S7300-48X2Q4C-48-Port-10G-Ethernet-L3-Plus-Switch- \(12\)
  4. Step 4: Enter the default username and password, admin/admin.

Troubleshooting

Loading Failure Troubleshooting
If the loading process fails, the system will continue to operate in its original state. In such a situation, users should first verify the physical port connections to ensure they are properly connected. If some ports are disconnected, reconnect them before attempting to reload the system. If the physical connections are secure, the next step is to examine the loading process information shown on the super terminal. If any input errors are detected, they should be corrected before reloading the system.

User Password Lost Troubleshooting
If system password is lost or forgotten, the password can be reset using the following method:

  1. Connect the console port of the switch to a computer using a console cable.
  2. Press “ctrl + b” to access the Uboot mode.Start the system with an empty configuration file with no password.
    Bootrom#boot_flash_nopass
    Bootrom#Do you want to revert to the default config file?[Y|N|E]:

Configuration System Troubleshooting

  1. Verify that the power supply is functioning correctly and that the console cable is appropriately connected.
  2. Confirm that the console cable is the appropriate type for the device being connected.
  3. Ensure that the control cable driver is appropriately installed on the computer.
  4. Verify that the settings of the HyperTerminal, such as baud rate, data bits, stop bits, and parity, are correctly configured.

Support and Other Resources

Product Warranty

S7300 series switches are backed by a 5-year limited warranty supported by QSFPTEK. And you are eligible to apply for a return or exchange of your items within 14 days of receiving them. For more details about applying qualifications, please live chat or email [email protected] for support.

www.qsfptek.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

QSFPTEK User Manuals

Related Manuals