Product Overview
The QSFPTEK S7600 Series Routing Switches (whose abbreviation is “S7600”) are highperformance1GE/10GE/40GE/100GE switches designed based on ethernet switching chip CTC7132. S7600’sproductposition is to meet the requirements of next generation Enterprise, Data Center, MetroandHCI(Hyper Converged Infrastructure) networks.
S7600’s QSFPTEKOS system software supports mainstream protocols and applications which can be conveniently deployed and managed
S7600 currently provide the following configurations:
S7600-24X2C: Standard 1U 19’’ rack mountable; 24×10/100/1000 Base-T
ports; 8x10GESFP+ports; Dualmodular AC power supply
S7600-24X2Q: Standard 1U 19’’ rack mountable; 48×10/100/1000 Base-T ports; 4x10GESFP+ports; Dualmodular AC power supply.
S7600-32C: Standard 1U 19’’ rack mountable; 24×10/100/1000 Base-T ports; 8x10GESFP+ports; Dualmodular AC power supply
S7600-48X8C: Standard 1U 19’’ rack mountable; 48×10/100/1000 Base-T ports; 4x10GESFP+ports; Dualmodular AC power supply
S7600-48Y8C: Standard 1U 19’’ rack mountable; 48x1GE SFP ports; 4x10GE
SFP+ ports; Dual modularACpower supply.
Product Characteristic
Based on Carrier Grade High Performance Chip
S7600 series routing switches, which are designed based on Ethernet switching
chip CTC7132. TheCTC7132 is Carrier Grade high-performance chip which help the
S7600 to meet the requirement ofMetro/Enterprise/Data
Varied Port Types
Support 1G / 10G / 25G / 40G / 100G ports to meet different network
requirements
System Design for Green and Energy Saving
Intelligent FAN adjustment and real-time power consumption monitoring
technology are providedfor thecostof maintenance redundancy and help to build
a green and energy saving data center.
Customized Profile for Different Deployment Scenarios
The Flexible Table Management (FTM) technology offers multiple table size
configurationprofilesasoptimized choices for different network scenarios.
Support up to 96K MAC address tables. Support upto56KIP routing tables.
IP routing tables. Intelligent Ethernet OAM: completed network fault managementand
performance guaranty
With the IEEE802.1ag and ITU-T Y.1731 end-to-end OAM, Ethernet service
providers canmonitortheservices, survey the end-to end performance and ensure
the service quality match the agreement. The fault management technique
includes CCM, LTM and LBM. Performance targets includemeasureforlatency and
jitter. S7600 Support remote management,network monitoring,network fault
indication,remote loopbackandMIBparameter retrieval according to the standard
802.3ah EFM
Data Center Features
S7600 support leading edge Data Center features: Priority Flow Control (PFC), explicit CongestionNotification (ECN) and Data Center TCP, etc. Support MLAG (Multi-Chassis Link Aggregation) to aggregate links across different devices. MLAGcanbuildan Active-Active system to improve the reliability of the network links from single board grade todevicegrade.MLAG use a peer link between to devices to aggregate two devices and make themas one devicelogically.Ports of two different devices join the aggregate ports together and all port can transmit the datatraffic. MLAGneed to management the device respectively, but the configurations are easier than stacking, reboot isNOTrequired after MLAG is configured. Forwarding and configuring are processing on local device, innormalcondition the traffic do NOT transmit trough the peer link, the bandwidth of peer link is not the bottleneckof thenetwork and the latency is low.
network and the latency is low. Support overlay technology (include NVGRE/VXLAN/GENEVE etc.). Overlay can make layer2 packetsacross the layer3 networks by using NVGRE/VXLAN/GENEVE header to encapsulate the entire Ethernet packets.Overlay resolves the problem of MAC table size limitation in traditional layer2 networks, resolves theproblemof VLAN id count limitation, and resolves the problem network dynamic adjustment which cannot achievebyVLAN/VPN. Use VXLAN for example, 24 bits VNI identifier can support at most 16777215 logicnetworks,layer2 networks built by VXLAN can keep the same IP/MAC etc. when move the virtue machine. MLAG and overlay features are also good candidates for switches in data center network. S7600 supports RPC- API for SDN(Software Defined Network). SDN is a new architecture of networkwhichcan substantially simplify the management and maintenance by separating the control plane anddataplaneofthe network.
High Reliability
S7600 are powered by Hot-swappable power modules which supports AC/DC 1+1 redundancy;Fanssupport2+1 redundancy;Support Real-time environment monitoring technology to detect the chipset temperature,status of fan and power, etc. Support LACP / ECMP / VRRP / VARP / STP/RSTP/MSTP / Smart Link / BFD / ERPS / G.8031/ G.8032/Load-Balancing, etc. to protect the network traffic all-around effectively. Patented technology “Sysmon” for CPU status monitoring can take action
Outstanding QoS Control
S7600 provides 10hardware queues per-port (8 unicast queues, 1 multicast queues, and1monitorqueue).Support multi-stage scheduling technology such as WDRR (Weighted Deficit Round Robin) / SP(StrictPriority) and TD (Tail Drop) / WRED (Weighted Random Early Detection) to prevent congestion. Supportflexible queue schedulingmechanism to do the shaping for queue or port traffic. Ingress and egress policer provide intelligent bandwidth monitoring, which support to adjust thegranularityaccording to the port speed. Both srTCM (Single Rate Three Color Marker) and trTCM(Two RateThreeColorMarker) can be supported
Triple-play Service Support with Bandwidth Guaranty for HighQuality
Application
S7600 offers high bandwidth for Triple-Play services such as IPTV, video monitoring. Thebuilt-inQoScapabilities and flexible queuing technologies guarantee high quality of services. Rich multicast protocol set (IGMP Snooping, IGMP v1/v2, PIM-SM) support up to 2K multicast groupsand4Klogical replications per group. With QSFPTEKOS software, IPTV service and multicast latency control arefullysupported.
Comprehensive Network Security Policy
S7600 supports subscriber-class / switch-class / network-class security control. IPv4 / IPv6 / MAC ACL can filter IPv4 / IPv6 / Non-IP packet respectively. Besides that, extendedIPv4/IPv6ACL which can match Layer2 / layer3 / layer4 information in one rule is available. The ACLs canapplytophysical ports / vlan / port group / vlan group. The members of port group or vlan group shareaset of ACLsand save the TCAM resource. ARP Inspection and IP Source Guard features prevent network from malicious ARP attack. Support CPUTraffic Protection, Storm Control and CPU load optimization features. Support centralized802.1x authentication feature to forbidden illegal user accessing network..
Convenient Management Features
Support varied management interfaces, include console port / in-band network ports / out-of-bandnetworkport / USB port. Support SNMP v1/v2/v3, Support CLI (Command Line Interface), web management, Telnetand FTP connection. Support OAM to make management more convenient, and support SSH2.0, SSL, etc.toensure security of management
Product Specifications
Items | S7600-48T4X | S7600-48S4X | S7600-24T8X |
---|---|---|---|
Size (H×W×D) | 4.36 x 44.0 x 37.0cm (1.73 x 17.5 x 14.6 in.) | ||
Weight | 5.1KG | 6.25KG | 6KG |
RS-232Ports | Serial | 1 RJ-45 port located at the left side of front panel | |
Management Ports | 1 RJ-45 out-of-band management port located at the left side |
of front panel
USB Ports| 1 Type-A USB port located at the left side of front panel
10/100/1000MbBase-T Ports| 48| –| 24
1Gb SFP Ports| –| 48| –
10GbEPorts| SFP+| 4| 4| 8
25GbEPorts| SFP28| –| –| –
40GbEPorts| QSFP+| –| –| –
100GbEPorts| QSFP28| –| –| –
10/100/1000MbBase-T POE Ports| –| –| –
Latency| Min: 660ns
CPU| SOC(Dual core/ARM A53)
Memory| 2 GB
Flash| 8 GB (eMMC)
Packet Memory| Buffer| 9 MB
Power supply| AC| Operating Voltage: 100 ~ 240V; 50/60HzMaximum Voltage : 90 ~
264V; 47~63Hz
Items| S7600-48T4X| S7600-48S4X| S7600-24T8X
---|---|---|---
| DC| Operating Voltage : -48 ~ -60V| NOT support
Airflow Option| Front-Rear
Hot-swappable Fans| 2 (1+1 redundant)| 1 Fixed AC power supply
Typical Power Draw| 42W| 58W| 41W
Max Power Draw| 55W| 70W| 55W
MTBF(Hour)| 204935| 189901| 204935
MTBF(Year)| 23.39| 21.68| 23.39
S7600 Series System Specifications
Table 3-1 Series System Specifications
Description | Specification |
---|---|
Operating Temperature | 0 to 45 ºC |
Storage Temperature | -40 to 70 ºC |
Relative Humidity | 0 to 95% (non-condensing) |
Table 3-2 Environment Specifications
Description | Specification |
---|---|
Safety Certifications | Ready to CE Marking |
Electromagnetic Emissions Certifications | Ready to FCC Part 15 Class A |
Ready to CE
Warranty| Limited warranty
Table 3-3 Safety and Compliance
Description | Specification |
---|---|
Safety Certifications | Ready to CE Marking |
Electromagnetic Emissions Certifications | Ready to FCC Part 15 Class A |
Ready to CE
Warranty| Limited warranty
S7600 Series Service Specifications
Table 3-4 Service specifications
Features | S7600-48T4X | S7600-48S4X | S7600-24T8X |
---|---|---|---|
Line speed forwarding | Switch capabi lity | 176 Gbps | 176 Gbps |
Throu ghput | 132 Mpps | 132 Mpps | 155 Mpps |
Forward mode | Support store-forward mode and cut-through mode | ||
Ethernet features | Support full duplex, half duplex, and auto-negotiation |
duplex Support auto-negotiation port speedSupport Jumbo Frame Support Flow
Control Support Storm Control Support Port-block Support Port-isolateSupport
L2 Protocol Tunneling
VLAN features| Support 4094 VLANsSupport VLAN access mode: Access /Trunk
Support Default VLANSupport VLAN ClassificationSupport basic QinQ, selective
QinQ and VLAN Mapping Support VLAN statisticsSupport Private VLAN Support
Guest VLANSupport Voice VLAN
MAC Address Table| Support static MAC addressSupport dynamic MAC address
learning and aging Support hardware learningSupport black hole MAC
addressSupport MAC Flapping detect
Link aggregation| Support Static Link aggregation Support LACPSupport Static
load balancingSupport dynamic load balancing (DLB) Support Self-healingSupport
port priority and active-standby mode
Reliability features| Support STP/RSTP/MSTP protocolSupport STP Protocol
Protection (BPDU Filter/Guard, Root Guard, Loop Guard, Anti TC-BPDU
attack)Support Single ERPS ring / tangent ERPS rings / intersecting ERPS rings
Support ERPS compatible with RRPPSupport G.8031 Support G.8032Support port
Loopback Detect Support BFDSupport VRRP Support MLAGSupport Ethernet OAM:
EFM/CFM/Y.1731Support Software class process monitoring(Sysmon) Support
Hardware Watch Dog
ARP features| Support static ARPSupport dynamic ARP leaning and aging Support
Gratuitous ARPSupport basic ARP-Proxy and local ARP-Proxy
IPv6 forwarding| Support ICMPv6 Support NDP Support PMTUSupport IPv6 static
routes Support RIPngSupport OSPFv3Support IPv6 over IPv4 Tunnel Support 6to4
TunnelSupport ISTAP Tunnel Support DHCPv6 Support IPv6 prefix listSupport VRRP
v3
Multicast features| Support IGMP v1/v2/v3 Support IGMP agent Support IGMP SSM
MappingSupport PIM-SM,PIM-SSM,PIM-DMSupport MLD v1/v2, MLD v1/v2 snooping
Support MVR and MVR6Support PIM-SM v6
Metro features| Support LDP
| Support MPLS Forwarding Support VPWSSupport VPLS Support MPLS OAM Support
MPLS StatsSupport L2VPN/L3VPN Support MPLS ACLSupport MPLS QoS
Data center features| Support VARP Support VXLAN Support GRE TunnelSupport
NVGRE Tunnel Support GENEVE Tunnel Support DCBXSupport priority-based flow
control (PFC) Support PFC Deadlock detectionSupport EVPN
QOS features| Support traffic classification based on COS/DSCP (simple
classification) Support traffic classification based on ACL ( complex
classification) Support queue scheduling based on traffic
classificationSupport Remark the priority fields(COS/DSCP) of the packet
Support flow redirectionSupport flow mirror Support traffic policing Support
traffic shaping Support traffic statisticsSupport SP(Strict Priority)
schedulingSupport WDRR (Weighted Deficit Round Robin) scheduling Support SP +
WDRR mixed schedulingSupport TD(Tail Drop)Support WRED (Weighted Random Early
Detection) Support ECN tags based on TD and WRED
Security features| Support SSH Support Radius Support TACAS+ Support
AAASupport port based dot1x and MAC based dot1x authentication/access
accounting/keep aliveSupport configure dot1x Guest via command or Radius
server
| Support access control list(ACL)Support traffic classification based on
source and destination IP / source and destination MAC / source and
destination layer for protocol number / VLAN IDSupport ACL matching User
defined fields (UDF) Support ACL active based on Time-Range Support ARP
inspectionSupport IP source guardSupport port security to limit the MAC
address learning on interface Support VLAN security to limit the MAC address
learning on interfaceSupport CoPP (Control Plane Protect) black & white list
and rate limit featuresSupport CPU Traffic Limit Support Prevent DDOS
attackSupport ACL filtering Telnet/SSH loginSupport Link-Flapping detection
Configuration and maintenance| Support DHCP Server Support DHCP Relay Support
DHCP Snooping Support DHCP Client Support DHCP Option82 Support RMONSupport
sFlow Support IP SLASupport IPFIX and MFP Support SGTSupport Latency/Buffer
Monitor Support EFD (Elephant Flow Detection) Support NTPSupport port
Errdisable state detection and recovery Support configure static DNS
clientSupport LLDP Support port loopbackSupport hardware loopback
(internal/external) Support to configure system timeSupport to configure time
zone
Debugging features| Support to Debug based on modulesSupport CPU/memory usage
display and alarmSupport Device temperature/PSU/FAN/status display and alarm
| Support user operation logsSupport Management of logs, alarms, and debugging
information Support VCT (Virtual Cable Test)Support detailed diagnostic-
information collection Support reboot information loggingSupport network
diagnostics (ping/traceroute)Support mirror: support use port/VLAN/CPU as
mirror source Support use port/port group/ VLAN / CPU as mirror destination
Support ERSPANSupport to CPU/From CPU packets statistics Support L2
pingSupport UDLD(Unidirectional Link Detection)
Management features| Support in-band and out-of-band management ports Support
privileged user priority and privileged commands Support User block
featureSupport Network management based on SNMPv1/v2c/v3 Support Public and
private MIBSupport Public and private TrapSupport Configuration and management
based on WEB UI Support Configuration and management based on RPC-APISupport
SmartConfig(Automatically configuration when system start) Support
OVSDBSupport change the system specifications by choose different STM
ProfilesSupport feature configuration based on License Support restore factory
default configuration Support manual/schedule rebootSupport upgrade with the
local image file/remote TFTP serverSupport online upgrade Uboot
File system| Support file system to manage the files and directories Support
upload/download files via FTP/TFTPSupport transmit files via Xmodem
S7600 Series
Manufacturer Part Number| Manufact urer Name| Safety| EMC|
Certifications
---|---|---|---|---
| Wuhan| EN 62368-1:| EN 55032: 2015| CCC
S7600-48S4X| QSFPTEK| 2020+A11:202| EN 55024: 2010| CE-LVD
| Communic| 0| EN 61000-3-2:2014| CE-EMC
| ations Co.,Ltd.| EN62479:2010| EN 61000-3-3:2013| FCCFCC ICES
| Wuhan| EN 62368-1: 2020+A11:2020EN62479:2011| EN 55032: 2015| ETL
| QSFPTEK| | EN 55024: 2010|
S7600-48T4X| Communic| | EN 61000-3-2:2014|
| ations Co.,| | EN 61000-3-3:|
| Ltd.| | 2014|
| Wuhan| EN 62368-1: 2020+A11:2020EN62479:2011| EN 55032: 2015| CCC
| QSFPTEK| EN 62368-1:
2020+A11:202
0| EN 55024: 2010| CE-LVD
S7600-24T8X| Communic| EN62479:2010| EN 61000-3-2:2014| CE-EMC
S7600-48T4X| ations Co.,| EN 62368-1:
2020+A11:202
0
EN62479:2011| EN 61000-3-3:| FCC
S7600-24T8X| Ltd.| EN 62368-1:
2020+A11:202
0
EN62479:2011| 2014| FCC ICES
Applications
HCI(Hyper-Converged Infrastructure)
S7600 with 1GE + 10GE/40GE/100GE ports are suitable for HCI (Hyper-Converged
Infrastructure networks. Using 1GE ports for management network and using
10G/40GE/100G ports for data traffic network. The following features of S7600
are available for this case: VLAN, LACP, STP/RSTP/MSTP, MLAG, etc.
Enterprise Data Center
S7600 series provide 1GE/10GE/40GE/100GE ports for Access or Aggregation
switches. The following figure shows a deployment example using the S7600
Series for Data Center Accessnetworktopology as TOR access devices The
following features of S7600 are available for this case: VLAN, LACP,RSTP&MSTP,
MLAG, DCB Features (PFC/QCN/ETS, Data Center TCP), OSPF,
QoS,Overlay(NVGRE/VXLAN/GENEVE), etc.
Figure 5-2 Data Center Servers Access Network with S7600 Series
Metro L2 Ring Network
Ring network topology allows service provider to establish robust network and
operate multiple services. The following figure shows the deployment example
using the S7600 Series for Metro L2 ring networktopologyas Aggregation or
Access devices. The following features of S7600 are available for this case:
QinQ/ ERPS/G.8032 / EFM / CFM / LACP / Smart-link, etc.
Figure 5-3 Metro L2 Ring Network topology with S7600 Series
Ordering Information
Table6-1 S7600 Series product
Product Number | Description |
---|---|
S7600-48T4X | Standard 1U 19’’ rack mountable |
48×10/100/1000 Base-T ports 4x10GE SFP+ portsDual modular AC power |
supplyFront-Rear Airflow, fixed FAN
S7600-48S4X| Standard 1U 19’’ rack mountable 48x1GE SFP ports4x10GE SFP+
portsDual modular AC power supply Front-Rear Airflow, fixed FAN
S7600-24T8X| Standard 1U 19’’ rack mountable 24×10/100/1000 Base-T ports
8x10GE SFP+ portsDual modular AC power supplyFront-Rear Airflow, fixed FAN
Extended Optics and Cables
Table6-2 Supported Optics and cables
Port type | Optics and cables | Note |
---|---|---|
Ethernet management port | RJ-45 connectors | |
Cat-5 UTP cabling | – | |
Console port | RJ-45-to-DB9 cable | for PC connections |
10/100/1000BASE-T Ports | RJ-45 connectors | |
Cat-5 UTP cabling | – | |
1GE SFP | LC fiber connectorsSingle-mode or Multimode fiber | – |
25GE SFP28 | LC fiber connectorsSingle-mode or Multimode fiber | – |
10GE SFP+ | LC fiber connectors | |
Single-mode or Multimode | – | |
Port type | Optics and cables | Note |
fiber | ||
40GE QSFP+ | LC fiber connectorsSingle-mode or Multimode fiber | – |
100GE QSFP28 | LC fiber connectorsSingle-mode or Multimode fiber | – |