QSFPTEK S5300-16S8TS4X 16-Port Gigabit Ethernet L2 Plus Switch User Guide

May 15, 2024
QSFPTEK

QSFPTEK S5300-16S8TS4X 16-Port Gigabit Ethernet L2 Plus Switch

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-product-
image

Specifications

  • Model : S5300-16S8TS4X
  • Type : 16-Port Gigabit Ethernet L2+ Switch
  • Ports : 16x 1G SFP, 8x 1G RJ45/SFP Combo, 4x 10G SFP+ Uplinks
  • Features : Support Stacking

Hardware Overview

Front Panel Ports
The front panel includes different types of ports

  • Combo Port : RJ45/SFP Combo port for versatile connections
  • SFP Port : SFP ports for 1G connections
  • SFP+ Port : SFP+ ports for high-speed 10G connections
  • CON Port : RJ45 port for console access

Front Panel LEDs
LED Indicators provide status information

  • SFP Status LED
  • SFP+ Status LED
  • SYS LED
  • PWR LED

Installation Instructions

Back Panel
The back panel includes essential components

  • POWER : Power switch for ON/OFF functionality
  • Grounding column : Ensures proper grounding for safety
  • AC power supply : Input voltage range from AC100-240V

Installation Requirements
Ensure safety and proper installation with these tips

  • Use necessary tools like a screwdriver and static-proof wristband.
  • Follow safety principles to prevent damage to humans or devices.
  • Keep the environment clean and well-ventilated.

Mounting the Switch
Securely mount the switch in a well-ventilated area with proper heat dissipation.

Connecting the Power
Plug the AC power cord into the switch power port and connect to an AC power source.

Connecting Ports

  • RJ45 Ports: Connect Ethernet cable between networking devices and switch RJ45 port.
  • SFP Ports: Insert SFP module into port and connect fiber patch cable for data communication.
  • SFP+ Ports: Insert SFP+ module into port and connect fiber patch cable for high-speed data communication.
  • Management Ports: Connect appropriate cables for management purposes.

FAQ

  • Q: How do I know if the switch is powered on?
    A: Check the PWR LED on the front panel; if it’s on, the device is powered.

  • Q: What should I do if the link on a port fails?
    A: If a link fails, check the corresponding LED status on the front panel for troubleshooting.

S5300-16S8TS4X Quick Start Guide

16-Port Gigabit Ethernet L2+ Switch
16x 1G SFP, with 8x 1G RJ45/SFP Combo, 4x 10G SFP+ Uplinks, Support Stacking

Introduction

The S5300-16S8TS4X is a managed gigabit access layer switch with 16x 1G SFP, 8x 1G RJ45/SFP combo, 4x 10G SFP+ uplink ports, supports stacking of up to 2 switches. It has built-in two intelligent fans, which can automatically adjust the fan speed to save on usage costs. The switch can be easily controlled and managed through both CLI and WEB interfaces, allowing for real-time monitoring and improved management efficiency. This makes the S5300-16S8TS4X an ideal choice for SMBs, enterprise networks, and campus networks.
We appreciate your decision to select S5300-16S8TS4X. This manual is intended to help you become acquainted with the switch design and provide instructions for implementing the switches into your network.

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(2\)

Accessories

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(3\)

Hardware Overview

Front Panel Ports

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(4\)

Ports Description
Combo Port RJ45/SFP Combo port
SFP Port SFP ports for 1G connection
SFP+ Port SFP+ ports for 10G connection
CON Port A baud rate of 9600bps, RJ45 port

Front Panel LEDs

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(5\)

LEDS Status Description
**** SFP **** / On
Off The link on the port is failed.
**** SFP+ **** / On
Off The link on the port is failed.
SYS LED / /
PWR LED / /

Back Panel

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(6\)

Abbrev Name Description
/ Grounding column The grounding must be fine
/ Power switch ON means the power is switched on, while OFF means the power

is cut off
POWER| AC power supply| Input voltage AC100-240V

Installation Requirements

Tools Preparation

  • Screwdriver
  • Static-proof wristband
  • Bolt
  • Ethernet cable
  • Other Ethernet terminal devices
  • Control terminal

Safety Principles
Keep dustless and clean during or after the installation.

  • Put the cover in a safe place.
  • Put tools in the right place where they are not easily falling down.
  • Put on relatively tight clothes, fasten the tie or scarf well and roll up the sleeve, avoiding stumbling the machine box.
  • Put on protective glasses if the environment may cause damage to your eyes.
  • Avoid incorrect operations that may cause damage to humans or devices.

Site Environment

  • Make sure that the workshop is well-ventilated, the heat of electrical devices is well-discharged
  • Avoid damaging devices by following the electrostatic discharge prevention procedure.
  • S5300-16S8TS4X Hardware Installation Manual
  • Put the machine box in a place where cool air can blow off the heat inside the machine box.
  • Make sure the machine box is sealed.

Mounting the Switch

Connecting the Power

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(7\)

  • Plug the AC power cord to the switch power port on the back rear.
  • Connect the other end of the power cord to an AC power source equipment.

Connecting the RJ45 Ports

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(8\)

  • Connect one end of the Ethernet cable to the RJ45 port on networking equipment, such as PC, printer, server, storage, etc.
  • Connect the other end of the Ethernet cable to the switch RJ45 port.

Connecting the SFP Port

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(9\)

  • Insert the SFP module into the SFP port.
  • Plug a fiber patch cable into the SFP transceiver.
  • Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the SFP+ Port

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(10\)

  • Insert the SFP+ module into the SFP+ port.
  • Plug a fiber patch cable into the SFP+ transceiver.
  • Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the Management Ports

Connecting the Console Port

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(11\)

  • Prepare a console cable.
  • Insert the RJ45 connector of the console cable into the console port on the switch.
  • Connect the DB9 female connector on the other end of the console cable to the serial port on the computer host.

Configuring the Switch

Configuring the Switch Using the Web-based Interface

  • Step 1 : Connect your computer to the switch using an Ethernet cable and open a web browser.
  • Step 2 : Set the IP address of the computer to 192.168.0.x (where “x” is any number from 2 to 254) and the subnet mask to 255.255.255.0.
  • Step 3 : Open a web browser and type http://192.168.0.2 in the address bar. Enter the default username and password (admin/admin).
  • Step 4 : Click sign-in to access the web-based configuration page.

Configuring the Switch Using the Console Port

  • Step 1 : Use the console cable to directly connect the switch console port to your computer.
  • Step 2 : Launch the terminal simulation software such as Hyper Terminal on the computer.
  • Step 3 : Configure the parameters of the terminal emulation software as follows: 9600 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.

QSFPTEK-S5300-16S8TS4X-16-Port-Gigabit-Ethernet-L2-Plus-Switch-image
\(13\)

  • Step 4 : Enter the default username and password (admin/admin).

Troubleshooting

Hardware Fault Analysis

  1. Power and cooling systems —power and fan
  2. Port, cable and connection —ports on the front panel of the switch and the cables connecting these ports

Faults Relative to Power and Cooling System
Do the following checkups to help remove the fault

  1. When the power on-off is at the “ON” location, check whether the fan works normally. If the fan does not work well, check the fan.
  2. If the switch is too hot, check whether the air outlet and air inlet are clean and then do relative operations in section 2.3 “Requirements for Common Locations”.
  3. If the switch cannot be started and the PWR indicator is off, check the power.

Faults Relative to Port, Cable and Connection
Do the following checkups to help remove the fault

  1. If the port of the switch cannot be linked, check whether the cable is correctly connected and whether the peer connection is normal.
  2. If the power on-off is at the “ON” location, check the power source and the power cable.
  3. If the CLI port does not work after the system is started up, check whether the CLI port is set to a baud rate of 9600 bps, eight data bits, no sum check bit, one stop bit and no traffic control.

Support and Other Resources

Product Warranty

S5300 series switches are backed by a 5-year limited warranty supported by QSFPTEK. You are eligible to apply for a return within 14 days and exchange within 90 days of receiving them.
For more details about applying qualifications, please live chat or email sales@qsfptek.com for support

5 Year Warranty

14-day Return Window

Documents / Resources

| QSFPTEK S5300-16S8TS4X 16-Port Gigabit Ethernet L2 Plus Switch [pdf] User Guide
S5300-16S8TS4X, S5300-16S8TS4X 16-Port Gigabit Ethernet L2 Plus Switch, 16-Port Gigabit Ethernet L2 Plus Switch, Gigabit Ethernet L2 Plus Switch, Ethernet L2 Plus Switch, L2 Plus Switch, Switch
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

QSFPTEK User Manuals

Related Manuals