QSFPTEK S5600-24T8X 24-Port Gigabit Ethernet L3+ Switch User Guide
- June 9, 2024
- QSFPTEK
Table of Contents
- QSFPTEK S5600-24T8X 24-Port Gigabit Ethernet L3+ Switch
- Introduction
- Accessories
- Hardware Overview
- Installation Requirements
- Mounting the switch
- Connecting the Management Ports
- Configuring the Switch
- Troubleshooting
- Support and Other Resources
- Product Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QSFPTEK S5600-24T8X 24-Port Gigabit Ethernet L3+ Switch
Introduction
The S5600-24T8X is a high-performance 1GE/10GE switch. The product position is to meet the requirements of next-generation Enterprise, Data Center, Metro, and HCI (Hyper-Converged Infrastructure) networks. We appreciate your decision to select S5600-24T8X. This manual is intended to help you become acquainted with the switch design and provide instructions for implementing the switches into your network.
Accessories
Hardware Overview
Front Panel Ports
Ports | Description |
---|---|
RJ45 | 10/100/1000BASE-T ports for Ethernet connection |
SFP+ | Hot-swappable SFP+ ports for 1/10G connection |
CON | An RJ45 console port for serial management |
ETH | An RJ-45 Ethernet management port |
USB
| A USB management port for software and configuration backup and offline software upgrade
Front Panel LEDs
LEDs | Status | Description |
---|
ID
| ****
Blue
| On| ID indication function enable
Off| ID indication function disable
SYS
| Green| On| The system is normal running
Amber| On| The system occur alarm or error.
–| Off| No power or System is not run or abnormality
ETH
| ****
Green
| On| Port link.
Blinking| Port is receiving or transmitting packets.
Off| Port not link.
RJ45 (Port 1-24)
| ****
Green
| On| 1G port link.
Blinking| 1G packets receiving or transmitting.
Amber
| On| 10/100M port link.
Blinking| 10/100M packets receiving or transmitting.
–| Off| Port not link
SFP+ (Port 25-32)
| ****
Green
| On| 10G port link.
Blinking| 10G packets receiving or transmitting.
Amber
| On| 1G port link.
Blinking| 1G packets receiving or transmitting.
–| Off| Port not link
Back Panel
Installation Requirements
Tools Preparation
- Flathead screwdrivers
- Phillips screwdrivers
- ESD-preventive wrist strap
Temperature/Humidity Requirements
Temperature | Humidity |
---|---|
0~45°C | 10%~95% |
Cleanliness Requirements
Substance | Unit | Concentration limit |
---|---|---|
DUST | Particle/m3 | ≤ 3 X 104 (No visible dust on the tabletop for three days) |
SO2 | mg/m3 | 0.2 |
H2S | mg/m3 | 0.006 |
NH3 | mg/m3 | 0.05 |
Cl2 | mg/m3 | 0.01 |
Note: The dust particle size is ≥ 5 μm
Mounting the switch
Connecting the Power
- Plug the AC power cord to the switch power port on the back rear.
- Connect the other end of the power cord to a AC power source equipment.
Connecting the RJ45 Ports
- Connect one end of the Ethernet cable to the RJ45 port on networking equipment, such as PC, printer, server, storage, etc.
- Connect the other end of the Ethernet cable to the switch RJ45 port.
Connecting the SFP+ Ports
- Insert the SFP+ module into the SFP+ port.
- Plug a fiber patch cable to the SFP+ transceiver.
- Connect the other end of the fiber to the device that you want to realize data communication.
Connecting the Management Ports
Connecting the Console Port
- Prepare an console cable.
- Insert the RJ45 connector of the console cable into the console port on the switch.
- Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.
Connecting the ETH Port
- Prepare an standard RJ45 Ethernet patch cable.
- Insert one end of the RJ45 Ethernet patch cable to the computer RJ45 port.
- Connect the RJ45 connector on the other end of the patch cable to the ETH port on the switch
Connecting the USB Port
- Prepare an Universal Serial Bus (USB) flash disk.
- Insert the USB to the switch USB port.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
-
Step 1: Connect your computer to the switch using an Ethernet cable and open a web browser.
Step 2: Set the IP address of the computer to 192.168.1.x (where “x” is any number from 2 to 254) and the subnet mask to 255.255.255.0. -
Step 3: Open a web browser and type http://192.168.1.1 in the address bar. Enter the default username and password (admin/admin).
-
Step 4: Click sign-in to access the web-based configuration page.
Configuring the Switch Using the Console Port
- Step 1: Use the console cable to direct connect the switch console port to your computer.
- Step 2: Launch the terminal simulation software such as HyperTerminal on the computer.
- Step 3: Configure the parameters of the terminal emulation software as follows: 115200 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.
- Step 4: Enter the default username and password (admin/admin).
Troubleshooting
Loading Failure Processing
After loading fails, the system will keep running in the original version. At this time, users should refer to the following steps to re-check:
- if physical port connections are good first. If some ports are not connected, then re-connect them to ensure that physical connections are correct, and begin re-loading.
- If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, we enter incorrect IP addresses of the Server and Switch, name of loading software, do not specify the correct working path of the correct TFTP server, and so on.
- if physical connections are good, and there are no input errors in the loading process but the loading fails finally, please contact agents for help.
User Password Lost
If the system password is lost or forgotten, the following method can be used to reset the password:
- Enter uBoot operation mode; see Chapter 5 for how to enter;
- Input boot_flash_nopass command to start the system in uBoot mode;
_ Note: _After using the boot_flash_nopass command, the system will clear up the startup-config files; before starting this operation, the startup- config files will be stored in flash:/startup-config.conf.old file.
Power System Troubleshooting
The switch can judge if its power system is faulty according to the PWR indicator on the front panel: when the power system works normally, the PWR indicator shall always keep lighting; when the PWR indicator is off, please check if:
- The power line of the switch is connected correctly.
- The EPS of the switch matches the power required by the switch.
Configuration System Troubleshooting
After the switch is powered on, if the system is normal, the startup information will be displayed on the configuration terminal; If no display information on the configuration terminal appears, maybe the configuration system is faulty, please check if:
- The power is normal.
- The cable of the configuration port (Console) is properly connected. If no problems have been found after the above checks, it is possible that the configuration cable is faulty or the parameter setting of the terminal (such as a super terminal) is incorrect, please check accordingly.
- Troubleshooting for the terminal displaying hashes: If the configuration terminal displays hashes, it is probable that the parameter setting of the terminal (such as a super terminal) is incorrect Please confirm the parameter setting of the terminal (such as HyperTerminal): baud rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA, selecting terminal emulation: VT100.
Support and Other Resources
- Contact us: https://www.qsfptek.com/company/contact-us.html
- Email: sales@qsfptek.com
- Customer Success: https://www.qsfptek.com/resources/customer-success-stories
Product Warranty
S5600 series switches are backed by a 5-year limited warranty supported by QSFPTEK. And you are eligible to apply for a return or exchange of your items within 14 days of receiving them. For more details about applying qualifications, please live chat or email sales@qsfptek.com for support.
- 5 Year Warranty
- 14-day Return Window
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>