amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal User Guide

June 9, 2024
amber connect

amber connect logo AGT400-m
Amber Govern T400-m
Professional LTE CAT Ml/GNSS Terminal
Quick Start Guideamber connect AGT-400-M Professional LTE CAT M1 GNSS
Terminal -

AGT-400-M Professional LTE CAT M1 GNSS Terminal

  1. Install Your device
  2. Download Amber Connect App
  3. Activate the device

Know your device

amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal - Know your
device

Pinout

amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal -
Pinout

Pin number Pin name Description
1 GND (-) Ground
2 CAN 1L SAE J1939 CAN interface Low channel 1
3 1WIRE POWER Power supply pin for Dallas 1-Wire® devices
4 DIN4 Digital input, channel 4
5 DIN2 Digital input, channel 2
6 CAN 2L SAE J1939 CAN interface Low channel 2
7 AIN2 Analog input, channel 2. Input range: 0-30V/0-10V DC
8 DOUT3 Digital output. Open collector output
9 DOUT2 Digital output. Open collector output
10 AIN3 Analog input, channel 3. Input range: 0-30V/0-10V DC
11 VCC (+) Power supply (+10-30 V DC)
12 CAN 1H SAE J1939 CAN interface High channel 1
13 1WIRE DATA Data channel for Dallas 1-Wire® devices
14 DIN3 Digital input, channel 3
15 IGN (DIN1) Digital input, channel 1. DEDICATED FOR IGNITION INPUT
16 CAN 2H SAE J1939 CAN interface High channel 2
17 AIN1 Analog input, channel 1. Input range: 0-30V/0-10V DC
18 DOUT4/AIN4 Digital output. Open collector output OR Analog input, channel
  1. Input range: 0-30V/0-10V DC
    19| DOUT1| Digital output channel 1. Open collector output
    20| K-Line| K-LINE interface for online Tachograph Vehicle Data transfer

Wiring scheme

amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal - Wiring
scheme

Set up your device

How to insert Micro-SIM card and connect the battery

  1. Unscrew 4 screws counter clockwise that are located on the bottom of the device.
  2. Remove the cover.
  3. Insert SIM card as shown with PIN request disabled or read Security info how to enter it later in Amber Configurator. Make sure that SIM card cut-off corner is pointing forward to slot. SIM slot 1 is closer to PCB, SIM slot 2 is the upper one.
  4. Connect battery as shown to device.
  5. After configuration, see “PC Connection (Windows)”, attach device cover back
  6. Screw in all screws. Device is ready to be mounted.

amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal - Unscrew
screws

Mounting recommendations

  • Connecting wires
  1. Wires should be connected while the module is not plugged in.
  2. Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires.
  3. The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again.
  4. If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied.
  5. Wires cannot be connected to the board computers or control units.
  • Connecting power source
  1. Be sure that after the car computer falls asleep, power is still available on chosen wire. Dependingon car, this may happen in 5 to 30 minutes period.
  2. When the module is connected, measure the voltage again to make sure it did not decrease.
  3. It is recommended to connect to the main power cable in the fuse box.

4. 3 A, 125 V external fuse

  • Connecting ignition wire
  1. Be sure to check if it is a real ignition wire power does not disappear while starting the engine.
  2. Check if this is not an ACC wire (when key is in the first position, most electronics of the vehicle are available).
  3. Check if power is still available when you turn off any of vehicles devices.
  4. Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen.
  • Connecting ground wire
  1. Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
  2. If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
  3. For better contact scrub paint from the spot where loop is going to be connected.

PAY ATTENTION! Connecting the power supply must be carried out in a very low impedance point of on-board vehicle network.
Connecting the GND at an arbitrary point to the mass of the car is unacceptable, as static and dynamic potentials on the line GND will be unpredictable, which can lead to unstable AGT400-M operation and even its failure.

LED indications

Navigation LED indications

Behaviour Meaning
Permanently switched on GNSS signal is not received
Blinking every second Normal mode, GNSS is working
Off GNSS is turned off because: Device is not working or Device is in sleep

mode
Blinking fast constantly| Device firmware is being flashed

Status LED indications

Behaviour Meaning
Blinking every second Normal mode
Blinking every two seconds Sleep mode
Blinking fast for a short time Modem activity
Off Device is not working or Device is in boot mode

Characteristics

Basic characteristics

Module

Name| AGT 400-M
Technology| LTE CAT M1/NB-IoT/GSM/GPRS/GNSS
GNSS
GNSS| GPS, GLONASS, GALILEO, BEIDOU, QZSS
Receiver| Tracking: 33/99 acquisition channels
Tracking sensitivity| -165 dBM
Accuracy| < 3 m
Hot start| < 1 s
Warm start| < 25 s
Cold start| < 35 s
Cellular
Technology| LTE Cat M1, UMTS, GSM
2G bands| B2/B3/B5/B8
4G bands| LTE FDD: B1/B2/B3/B4/B5/B8/B12/B13/B18/ B19/B20/B26/B28
LTE TDD: B39 (For Cat M1 Only)
Data transfer| LTE: Max. 375Kbps (DL)/Max.375Kbps (UL)
GPRS: Max. 85.6Kbps (DL)/Max. 85.6Kbps
(UL) GSM: GPRS: Max 107Kbps (DL)/Max 85.6Kbps (UL)
Data support| SMS (text/data)
Power
Input voltage range| 10-30 V DC with overvoltage protection
Back-up battery| 550 mAh 8,4V Ni-MH battery
Internal fuse| 3 A, 125 V
2 W max. Current consumption at 12 V| GPRS: average 60 mA
Nominal: average 45 mA
GNSS sleep: average 31 mA
Deep Sleep: average 4 mA
Online Deep Sleep: average 13 mA
2 W max. Current consumption at 24 V| GPRS: average 32 mA
Nominal: average 22 mA
GNSS sleep: average 12 mA
Deep Sleep: average 2,6 mA
Online Deep Sleep: average 6.7 mA
Bluetooth
Specification| 5.0 + LE
Supported peripherals| Temperature and Humidity sensor, Universal BLE sensors support
Interface
Digital Inputs| 4
Digital Outputs| 4
Analog Inputs| 4
1-Wire temperature sensors| 6
1-Wire iButton| 1
RS232| 2
RS485| 1
CAN J1939| 2
J1708| 1
K-Line| 1
LVCAN/ALLCAN| 1
GNSS antenna| External High Gain
GSM antenna| External High Gain
USB| 2.0 Mini-USB
LED indication| 2 status LED lights
SIM| Micro-SIM
SIM| 2x SIM Card (Dual-SIM)
Memory| 2MB internal flash memory and external SD card up to 32 GB.
Features
Sensors| Accelerometer
Scenarios| Green Driving, Over Speeding detection, Jamming detection, Excessive Idling detection, Crash detection, Immobilizer, iButton Read Notification, Towing detection,
Functionalities| Crash detection, Auto Geofence, Manual Geofence, Trip Detection, Odometer, DDD download and Tacho Online Data
Sleep modes| GPS Sleep, Online Deep Sleep, Deep Sleep
Configuration and firmware update| FOTA Web, FOTA, Amber Configurator (USB)
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control,
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring| LLS (Analog), LV-CAN, ALL-CAN, CAN FMS, RS232/RS485 Fuel Sensor, Ultrasonic level sensor
Ignition detection| Digital Input , Accelerometer, External Power Voltage
Physical specification
Dimensions| 104,1 x 76,8 x 31,5 mm (L x W x H)
Weight| 197 g
Operating environment
Operating temperature (without battery)| -40 °C to +85 °C
Storage temperature (without battery)| -40 °C to +85 °C
Battery charge temperature| Ta = 20 ± 5 ℃ (Ambient Temp.)
Battery discharge temperature| Ta = 20 ± 5 ℃ (Ambient Temp.)
Battery storage temperature| -20 °C to +45° C
Ignition detection| Digital Input 1, Accelerometer, External Power Voltage, Engine
Operating humidity| 5% to 95% non-condensing
Ingress Protection Rating| IP41

Electrical characteristics

Characteristic description Value
Min. Typ.

Supply Voltage
Supply Voltage (Recommended Operating Conditions)| +10|  | +30| V
Digital Output (Open Drain grade)
Drain current (Digital Output OFF)|  |  | 120| μA
Drain current (Digital Output ON, Recommended Operating Conditions)|  |  | 0.5| A
Static Drain-Source resistance (Digital Output ON)|  | 400| 300| mΩ
Digital Input
Input resistance (DIN1)| 15|  |  | kΩ
Input resistance (DIN2)| 15|  |  | kΩ
Input resistance (DIN3)| 15|  |  | kΩ
Input resistance (DIN4)| 15|  |  |
Input voltage (Recommended Operating Conditions)| 0|  | Supply voltage| V
Input Voltage threshold (DIN1, DIN2, DIN3,DIN4)|  | 7.5|  | V
Analog Input

Input voltage (Recommended Operating Conditions), Range 1| 0|  | +10| V
Input resistance|  | 120|  | kΩ
Input Voltage (Recommended Operating

Conditions), Range 2

| 0|  | +30| V
Input resistance|  | 147|  | kΩ
1-Wire
Supply voltage| +3.3|  | +3.9| V
Output inner resistance|  | 7|  | Ω
Output current (Uout > 3.0 V)|  | 30|  | mA
Short circuit current (Uout = 0)|  | 75|  | mA
CAN Interface

Internal terminal resistors CAN bus|  | 120|  | Ω
Differential input resistance| 19| 30| 52| kΩ
Recessive output voltage| 2| 2.5| 3| V
Differential output voltage| 0.5| 0.7| 0.9| V
Common mode input voltage| -30|  | 30| V

Safety information

This message contains information on how to operate AGT400-M safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

  • The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10…+30 V DC.
  • To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are  visible. They show the status of device operation.
  • When connecting the 2×10 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
  • Before dismounting the device from the vehicle, the 2×10 connector must be disconnected.
  • The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard.
  • The device AGT400-M is not designed as a navigational device for boats.

| Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
---|---
| All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
| The device must be connected only by qualified personnel.
| The device must be firmly fastened in a predefined location.
| The programming must be performed using a PC with autonomic power supply.
| Installation and/or handling during a lightning storm is prohibited.
| The device is susceptible to water and humidity.

Certification and Approvals

  • AGT400-M CE / RED
  • AGT400-M CE E-Mark
  • AGT400-M CE REACH
  • AGT400-M CE Declaration of IMEI assignment
  • AGT400-M CE Declaration of device operation temperature

| This sign on the package means that it is necessary to read the User‘s Manual before your start using the device. Full User‘s Manual version can be found in our Wiki.
---|---
| This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste.
| Hereby, Amber declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization: European Directive 2014/53/EU (RED).

Warranty

Amber connect guarantees its products to be free of any manufacturing defects for a period of 24 months. With additional agreement we can agree on a different warranty period, for more detailed information please contact our sales manager.
All batteries carry a reduced 6 month warranty period.
If a product should fail within this specific warranty time, the product can be:

  • Repaired
  • Replaced with a new product
  • Replaced with an equivalent repaired product fulfilling the same functionality
  • Amber can also repair products that are out of warranty at an agreed cost.

Warranty Disclaimer

Amber products are intended to be used by persons with training and experience. Any other use renders the limited warranties expressed herein and all implied warranties null and void and same are hereby excluded. also excluded from this limited warranty are any and all incidental or consequential damages including but not limited to, loss of use or revenue, loss of time, inconvenience or any other economic loss.

Need help? Contact 24/7 live support!
In App Chat
support@amberconnect.com
Chat via website www.amberconnect.com
Works with Android phones and tablets, iPhone, iPad. Compatible with Chrome, Mac and PC web browsers.
Scan this PR code to download your App
amber connect AGT-400-M Professional LTE CAT M1 GNSS Terminal -
qrhttp://onelink.to/ng48h2

Amber Connect
©2022 Amber Connect Limited. All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

amber connect User Manuals

Related Manuals