Specification

Dimension 78.041.013.0mm
Weight 38g
Voltage Range 7.5-90V
Backup Battery 270mAh/3.7V
Operation Temperature -20°C to +70 °C
Humidity 20% to 80%
Standby Time 50 hours
GSM Frequencies 850/900/1800/1900 MHz
GPRS Class 12, TCP/IP
GPS Channel 66
GPS Sensitivity -165dBm
Acquisition Sensitivity -148dBm
Position Accuracy <10m
TTFF (Open sky) Cold start <45s, Hot start <2s
GSM/GPS Antenna Built-in design
LED Indicator GSM-green, GPS-blue, Power-red
Data Transmit TCP, SMS
Geo-fence Alarm activated when the vehicle enters or leaves the specified

area
Speeding Alarm| Alarm activated when speed goes higher than the pre-set value
Low Power Alarm| Alarm activated when backup battery is running out.
Non-movement Detection| Movement alarm activated by built-in 3D motion sensor
Mileage Report| Track by time/distance interval
Remote engine mobilization/immobitization| Mobilize/immobilize engine

LED Indications

GPS LED Indicator – RED

Flashing| Low battery
Slow flashing| Fully charged/ functioning normally
Solid red| Charging
Off| Power off or low battery
GPS LED Indicator – BLUE|
---|---
Flashing (interval 0.1s)| Searching for BD/GPS signal
Solid blue| BD/GPS positioned
Off| GPS asleep or off
GPS LED Indicator – GREEN

Quick Flashing| GSM initializing
Slow flashing| Receiving GSM signal normally
Solid green| Connected to GPRS network
Off| No GSM signal or no SIM card

Getting Started

Please follow the instructions below to ensure safe and correct use of your device.

Note : Please ensure that there is enough credit on your SIM card. If you will be using the GPRS function, pay attention to the current SIM card GPRS charge.

  1. Switch on
    Begin by assembling and setting up your device before its first use.

  2. Open the SIM card cover.

  3. Insert the SIM card.

  4. Turn the battery switch to ON.

  5. Close the SIM card cover and connect the device to the external power line, which will be used to charge the terminal and built-in battery.

  6. Switch off

  7. Toggle the battery switch to OFF.

  8. Charge the device
    Plug in the device to connect or plug in the charging cable. The charging cable with 2A FUSE for short-circuit over current protection.amber Connect
ACC300 GPS Vehicle Tracker fig \(1\)

  9. Installing the device Find a location inside the vehicle where the device will not be found. Your device has a built-in GSM antenna and a GPS antenna. During installation, please ensure that the device is facing up:amber Connect ACC300 GPS Vehicle Tracker fig \(2\)

  10. Under the dashboard below the front windshield.

  11. In the parcel shelf the rear.

  12. In the front bumper (non-material face), ensure the device does not get wet.

  13. Under the wiper version (non-metal), ensure the device does not get wet.

  14. Non covert installation: affix the device to the dashboard below the windshield.

  15. Device wiring

  16. The standard voltage is 9V-90V; the red wire is the positive and the black wire is the negative

  17. Connect the black wire ground.

  18. Device wiring diagram Subject to permissible laws in your country. Play close attention to the diagram description; the battery is 9-90V and the relay remains12V/ 24/.

  19. Power/ACC/Tele-cut-off (petrol/electricity) control line (4 pin)

  20. Your device comes with a power cord and is designed to use only manufacturer- specified wiring accessories. The re line is positive while the black is negative (this side should not be connected to the ground wire).

  21. The ACC line (orange) connects to the ACC switch of the vehicle. Please be sure to connect to the ACC line, otherwise the device will not detect ignition status.

  22. Engine immobilization (petrol/electricity) control line (yellow) is connected to pin 86 Tele-cutoff (petrol/electricity) relay (equal to the yellow line of the relay socket)

Troubleshooting

Problem Causes Solutions
Red LED does not work when power is connected   Replace the fuse
Blown fuse
  Wrong installation of SIM card Check SIM card installation (install SIM

card)
Fail to connect to network| Debris on the Sim card’s iron surface| Clean SIM card surface
Nonfunctioning SIM| Contact internet service provides
 | Beyond GSM service area| Re-locate to GSM service area
 | Bad signal| Re-try in an area with better signal


Fail to charge

| The voltage is unsuitable| Connect to power with suitable voltage
 | Improper connection| Check connection with charger

Need help?
Contact 24/7 live support!
In App Chat
support@amberconnect.com
Chat via website www.amberconnect.com
Works with Android phones and tablets, IPhone, IPad. Compatible with Chrome, Mac and PC web browsers.
Scan this OR code to download your App
2022 Amber Connect Limited. All rights reserved

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

amber connect User Manuals

Related Manuals