Honeywell RLV4300 5-2 Programmable Thermostat Owner’s Manual

June 9, 2024
Honeywell

Honeywell RLV4300 5-2 Programmable Thermostat

![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-1](https://manuals.plus /wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat- FIG-1.png)

About your new thermostat

This thermostat is designed to control an electric heating system such as a baseboard heater, a radiant ceiling, a convector or a fan-forced heater.

  • The thermostat CANNOT be used with:
    • a resistive load under 1.25 A
    • a resistive load over 12.5 A
    • a system driven by a contactor or a relay (inductive load)
    • a central heating system
  • SUPPLIED PARTS
    • One (1) thermostat
    • Two (2) 6-32 mounting screws
    • Two (2) solderless connectors

Do you need assistance?
We are here to help. Call 1-800-468-1502.

Controls

![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-2](https://manuals.plus /wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat- FIG-2.png)

Display

![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-3](https://manuals.plus /wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat- FIG-3.png)

Installation guidelines

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.

  • All cables and connections must comply with local electrical codes.
  • This thermostat has tinned copper wires for line and load connections. Special CO/ALR solderless connectors must be used if these wires will be connected to aluminium conductors.
  • Install the thermostat onto an electrical box.
  • Install the thermostat about 1.5 m (5 feet) high, on an inside wall facing the heater.
  • Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.
  • Do not install the thermostat on a wall that conceals chimney or stove pipes.
  • The thermostat wires are not polarized; either wire can be connected to the load or to the power supply.

Wiring

Connect the thermostat wires to the heating system (load) and to the power supply using solderless connectors for copper wires.

![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-4](https://manuals.plus /wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat- FIG-4.png)

Mounting the thermostat

  • Loosen the screw underneath the thermostat and separate the faceplate from the wallplate.
    NOTE: The screw remains captive and cannot be completely removed.

  • Mount the wallplate to the electrical box using the provided screws. Insert the screws through the two left or the two right mounting holes of the wallplate.
    Reinstall the faceplate onto the wallplate and tighten the screw underneath the thermostat.
    NOTE: If there is a protective film or sticker on the thermostat’s screen, peel it off.

  • Apply power to the heating system. Verify the installation by checking that the heating system can be turned On by raising the setpoint using the Up button or turned Off by lowering the setpoint using the Down button.
    WARNING: Keep the thermostat’s air vents clean and free from obstructions.

Advanced settings

NOTE: The parameter tables are on the following pages.

  1. Pull the cover down.
  2. Briefly insert a pointed object (e.g., paperclip) through the  advanced setting opening. The first parameter will appear.
  3. To display the next parameter, press the Mode button.
  4. To modify a parameter, press the Up or Down button.
  5. To exit the menu, press the Ret button or do not press any button for 1 minute.![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-8](https://manuals.plus/wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat-FIG-8.png)
    • Early Start is used in Automatic mode only. When Early Start is enabled (On), the thermostat determines when to start heating so the desired temperature be reached at the beginning of periods 1 and 3. When Early Start is disabled (Off), heating does not start in advance, and therefore the desired temperature will not yet be reached at the beginning of these periods.
    • When Automatic Daylight Saving Time is enabled (On), the thermostat automatically switches to daylight saving time on the second Sunday of March and to normal time on the first Sunday of November.![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-9](https://manuals.plus/wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat-FIG-9.png)
    • Available only if Daylight Saving Time is enabled (On).
    • Generally set to 15-second cycle (Std) as it provides better temperature control. However, set to 5-minute cycle (Fan) if you have a fan-forced heater to prevent premature fan motor burnout. Fan appears on the thermostat’s screen when 5-minute cycle is selected.

Clock and day setting

The clock must be set when Time appears on the screen.

  1. Pull the cover down.
  2. Press the Day button to set the day.
  3. Use the Hour and Min buttons to set the clock.
  4. Press the Ret button to exit.

Temperature display and setting

The thermostat normally displays the room (measured) temperature.

  • To display the set temperature (setpoint), press the Up or Down button once. The setpoint temperature will remain on the screen for 5 seconds.
  • To change the setpoint temperature, press the Up or Down button repeatedly until the desired temperature is displayed.
  •  The screen is backlit for 12 seconds when any button is pressed.

Automatic mode (running the schedule)

  • To place the thermostat in Automatic mode, press the Mode button until Auto appears on the screen. The current period number also appears.
  • In this mode, the thermostat follows the programmed schedule.
  • You can program up to 4 periods in a day. You can set 2 different programs: one for the weekdays (Monday to Friday) and another one for the weekend (Saturday and Sunday).
  • By default, the thermostat is programmed with the following schedule:
    Period| Monday to Friday| Saturday & Sunday
    ---|---|---
    | Start Time| Temperature| Start Time| Temperature
    1| Wake| 6:00| 21.0°C (70°F)| 6:00| 21.0°C (70°F)
    2| Leave| 8:00| 16.0°C (61°F)| —| —
    3| Return| 18:00| 21.0°C (70°F)| —| —
    4| Sleep| 22:00| 16.0°C (61°F)| 22:00| 16.0°C (61°F)

Temporary Override
You can temporarily override the current temperature using the Up or Down button. The new setpoint will be used until the end of the current period. During the override, Auto flashes on the screen.

To modify the schedule:

  1. Press the Mode button until Auto appears on the screen.

  2. Press the Pgm button. Period 1 of the weekday (Monday to Friday) program is displayed

  3. To display another period, press the Pgm button.

  4.  To toggle between the weekday (Mon to Fri) program and the weekend (Sat & Sun) program, press the Day button.

  5. Press the Hour and Min buttons to set the start time of the displayed period.
    NOTE: To cancel the period, press the Mode button. The thermostat will display –:–. During operation, the thermostat will skip over that period.

  6. Press the Up or Down button to set the temperature of the displayed period.

  7. Repeat steps 3 through 6 to set another period.

  8.  Press the Ret button to end programming.![Honeywell-RLV4300-5[-2-Programmable-Thermostat-FIG-11](https://manuals.plus/wp-content/uploads/2023/03/Honeywell-RLV4300-5-2-Programmable-Thermostat-FIG-11.png)

Manual mode (permanent override of schedule)

To place the thermostat in Manual mode, press the Mode button until Man appears on the screen. In this mode, any modification to the temperature must be done manually. Press the Up or Down button to set the temperature. The default setting is 21°C (70°F).

Economy mode

To place the thermostat in Economy mode, press the Mode button until Econo appears on the screen. This mode is ideal for weekend residences (cottages) as it can be used to keep the temperature at an economy level during most of your absence and raise the temperature to a comfortable level by your usual arrival time. If you do not show up at your cottage, the temperature will return to the economy level until the following weekend.

The Economy mode has two periods which you can set as follows:

Period Temperature Start Time

1

|

Set to a comfortable level (e.g., 22°C).

| Set the day and time that you want the tem- perature to start rising so that the comfort- able level is reached by the time you arrive (e.g., Friday at 3:00 pm).

2

|

Set to an economy level (e.g., 15°C).

| Set the day and time that you want the temperature to start dropping to the economy level if you do not show up (e.g., Friday at 8:00 pm).

The Economy mode can be used as follows:

  • Place the thermostat in Economy mode during your absence.
  • When you arrive, place the thermostat in Automatic mode or in
  • Manual mode before the temperature drops to the economy level.
  • When you leave, switch the thermostat back to Economy mode.

To program the two periods of the Economy mode:

  1. Press the Mode button until Econo appears on the screen.
  2. Press the Pgm button. Period 1 is displayed.
  3. Press the Day button to set the start day of the displayed period.
  4. Press the Hour and Min buttons to set the start time of the displayed period.
  5. Press the Up or Down button to set the temperature.
  6. Press the Pgm button to select Period 2.
  7.  Repeat steps 3 through 5 to set Period 2.
  8. Press the Ret button to end programming.

Temporary Override
You can temporarily override the current temperature using the Up or Down button. The new setpoint will be used until the end of the current period. Econo flashes during the override.

Power outage

During a power outage, the thermostat display remains lit for the first 2 minutes. During this time, the LP (low power) indicator appears and all buttons are disabled. Then the screen turns blank. The settings are stored in memory. When power returns, the thermostat returns to the mode of operation preceding the power outage. If the power failure exceeded 5 hours, the clock and date must be re-adjusted. Set Automatic Daylight Saving Time back to On if you wish to continue using the feature.

In case of difficulty

PROBLEM SOLUTIONS
Thermostat’s housing is hot. This is normal.

Wrong temperature is dis- played.

| Correct the situation if any of the following exists:

•           The thermostat is exposed to an air draft.

•           The sticker on the thermostat’s screen has not been removed.

•           The thermostat is located near or above a heat source such as a light dimmer.

Wrong time is displayed.| The time is not yet set or the thermostat was with- out power for more than 5 hours.


Temperature does not change according to the programmed schedule.

| •           Ensure the thermostat is in Automatic mode.

•           Check the clock and the schedule. If the thermostat is configured for 12-hour format, ensure that PM appears on the screen when afternoon times are displayed.

LP appears on the screen or the screen is blank despite there is no power outage.| The thermal circuit breaker in the heater is opened. This can happen if the heater is obstructed by furniture or curtain and has over- heated, or if the thermal circuit breaker is defec- tive or too sensitive.

Specifications

  • Su p ply: 120/240 VAC, 60 Hz
  • Minimum load: 1.25 A (resistive only)
    • 150 W @ 120 VAC
    • 300 W @ 240 VAC
  • Maximum load: 12.5 A (resistive only)
    • 1500 W @ 120 VAC
    • 3000 W @ 240 VAC
  • Display range: 0°C to 50.0°C (32°F to 99°F)
  • Setpoint range: 5.0°C to 27.0°C (41°F to 81°F)
  • Resolution: 0.5°C (1°F)
  • Storage temperature: -20.0°C to 50.0°C (-4°F to 120°F)

Warranty

  • Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
  • If the product is defective,
    1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or
    2. call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley, MN 55422, or whether a replacement product can be sent to you.
  • This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
  • Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above.
  • HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
  • THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
  • This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
  • If you have any questions concerning this warranty, please write to Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write to Retail Products ON15-02H, Honeywell Limited/Honeywell limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.

Automation and Control Systems

  • Honeywell International Inc.
  • 1985 Douglas Drive North
  • Golden Valley, MN 55422
  • http://yourhome.honeywell.com
  • Honeywell Limited
  • 35 Dynamic Drive
  • Scarborough, Ontario M1V 4Z9
  • Printed in China

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals