DIGITUS DN-651132 8-Port 10-100Base-TX to 100Base-FX Industrial Ethernet PoE Switch Installation Guide

June 9, 2024
DIGITUS

 DN-651132 8-Port 10-100Base-TX to 100Base-FX Industrial Ethernet PoE Switch
Installation Guide
DIGITUS DN-651136 Industrial Ethernet PoE Switch 8-port 10/100/1000Base-TX
+ 1000Base-FX Industrial
Ethernet (PoE) Switch
Quick Installation Guide
DN-651132 & DN-651133

Overview

Industrial Ethernet switch with 8-Port 10/100/1000Mbps RJ45 +1 Port 1000Mbps SFP (DN-651137 support PoE), the Product meet CE, FCC, RoHS standards. Network switch has the operating temperature of -40°C ~ 80°C, has the super firmness can adapt to all kinds of harsh environment, can also be conveniently placed in the compact space of the control box. The installation characteristics of the guide rail, wide temperature operation, IP40 protection class housing and LED indicator light make the switch a plug and play industrial grade device, providing a reliable and convenient solution for users to network their Ethernet devices.

Switch Panel

DIGITUS DN-651136 Industrial Ethernet PoE Switch - Fig
1 Side panel : P1 and P2 are the number of connecting terminals, P+1 and P-1 are respectively to the positive and negative poles to be connected; Earthing screw, used for earthing equipment.
DIGITUS DN-651132 8-Port 10-100Base-TX to 100Base-FX Industrial Ethernet
PoE Switch fig 1Front panel: The yellow light on the port is the LINK light, which is on when the connection is established and the data transmission is flashing.
The green light is PoE light, which is only on when the switch port is supplying power to the PD devices. Power indicator light is on when connecting with Power.
Switch size (mm)     DIGITUS DN-651136 Industrial Ethernet PoE Switch -
Fig 3

Features

  • The use of high quality photoelectric integration module to provide good optical and electrical characteristics

  • Ensure reliable data transmission and long working life

  • Support full duplex or half duplex mode, with automatic negotiation capability

  • Network port support automatic cross identification

  • Internal storage and forwarding mechanism, support a variety of protocols

  • In line with industrial operating standards, the average trouble-free work in more than 300,000 hours

  • Working power supply:
    DN-651132: …………………..DC 12-52V
    DN-651133 (PoE):……………… DC 48-57V

  • Lightning Surge Protection (Power): 5000A (8/20μs)

Specification

4.1 Standard:
IEEE802.3 10Base-T;
IEEE802.3i 10Base-T;
IEEE802.3u; 100Base-TX/FX
4.2 Interface:
8-Port 10/100Mbps RJ45+1
Port 100Mbps Base-FX Industrial Switch
4.3 Work environment:
Working: -40 ~ 80 °C
Storage: -40 ~ 80 °C
4. 4 Switch:
Bandwidth: 1.8Gbps
Packet Buffer Memory: 1.25Mbit
Packet Forwarding Rate: 1.4Mpps
MAC Address Table: 4K
4.5 Power supply:
Input voltage: DC12-52V (two-way power redundancy backup);
Access terminal: terminal block;
Support dual power redundancy;
Support built-in over current 4.0A protection;
Support reverse connection protection
Max Power consumption: 3W
4.6 Mechanical characteristic:
4.6 Mechanical characteristic:
IP40 aluminum housing
DIN rail install
Natural cooling, no fan
Weight: 0.76Kgs
Measurement: 143.7 x 103 x 44.2 mm
4.7 Industrial standard:
FCC Part 15 Subpart B, EN55032, Class A
IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air)
IEC61000-4-3 (RS): 10V/m (80~1000MHz)
IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port: ±2kV
IEC61000-4-5 (Surge): Power Port: ±2kV/DM, ±4kV/CM;
Data Port: ±2kV
IEC61000-4-6 (CS): 3V (10 kHz-150 kHz); 10V (150 kHz-80 MHz)
IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s)
Frequency range: 150kHz-80MHz
Impact: IEC60068-2-27
Free Fall: IEC60068-2-32
Vibration: IEC60068-2-6

Interface Definition

5.1 10/100/1000Base-TX Ethernet interface:
This series of switches provides MDI/MDI-X self-identification with cable support on all 10/100/1000Base-TX ports. In use, the Ethernet port of the switch can be connected with other Ethernet terminal devices through network cables (direct or cross). Please use Class 5 shielded twisted pair. The Ethernet port pin definition is shown in the following figure:DIGITUS
DN-651136 Industrial Ethernet PoE Switch - Fig 4

RJ45 port supports automatic MDI/MDI-X operation, you can use a straight line to connect to the PC or server, connect to other switches or hubs. In the through line (MDI), pins 1, 2, 3, 4, 5, 6, 7, 8 correspond to the connection;
For the MDI-X port of a switch or hub, cross lines are used: 1-3, 2-6, 3-1, 6-2, 4-7, 5-8, 7-4, 8-5.1000Base-T (X) pins are defined as follows:

Pin No. MDI signal MDI-X signal
1 TX+ RX+
2 TX- RX-
3 RX+ TX+
6 RX- TX-
4,5,7,8

Note: “Tx ±” refers to send data, “Rx ±” refers to received data,  and “-“refers to unused data.
5.2 1000base-FX Ehernet interface
This device provides 100Base-FX SFP slot.
5.2.1 Patch cord classification
According to the transmission mode of light in the fiber, it can be divided into multi-mode fiber and single-mode fiber. Multimode fiber has a thick glass core (50 or 62.5μm), which can transmit light in various modes. However, the high inter-mode dispersion limits the frequency at which digital signals can be transmitted, so multimode fibers can be transmitted over relatively close distances (typically only a few kilometers).
The single-mode fiber has a very thin glass core (core diameter, usually 9 or 10μm) and can transmit only one mode of light. Therefore, it’s inter – module dispersion is very small, and it is suitable for remote communication. Under normal circumstances, the skin is orange for multi-mode, yellow for single mode.
5.2.2 Patch cord overview
LC to LC patch cord
DIGITUS DN-651132 8-Port 10-100Base-TX to 100Base-FX Industrial Ethernet PoE
Switch fig 2

LED Indicator

LED indicator Status Definition
Power Red LED on Power supplying in normal
Red LED off Power supply abnormal or no powering
RJ45 indicator Yellow LED on Network connection in normal
Yellow LED flashing Link communication in normal
Green LED on PoE feeding in normal
Yellow/Green LED off No connection at port
LINK/ACT Green flashing Optical work in normal

Installation caution

7.1 Installation precautions
In order to avoid damage to equipment and personal injury caused by improper use, please follow the following precautions:

  • In order to avoid damage caused by falling of the equipment, please put the equipment in a stable environment.
  • When supplying power to the equipment, pay attention to confirm the range of power supply voltage, as well as the positive and negative poles of the power supply, so as not to damage the equipment by wrong operation.
  • In order to reduce the risk of electric shock, ensure that the equipment is well grounded in the working environment.
  • No matter when, please do not arbitrarily remove the equipment shell.
  • When placing the switch, please avoid the area with dust and strong electromagnetic interference

7.2 Din rail installation:
The first step is to check the grounding and stability of the guide rail: the guide rail slot of the switch is clamped into the guide rail.
The second step: from the center to both sides of the guide rail positioning screws in order. Step 3: Use screws to fix the mounting rail card slot on the fixed guide groove at both ends of the guide rail to ensure that the guide rail and the switch are fixed on the guide rail vertically and stably.
7.3 grounding
Fix the grounding wire to the grounding screw above the switch, and ensure good reliable connection of the grounding system.
7.4 Power Connection
Insert the power cord into the specified position of the 6-core terminal and insert the terminal into the standard power supply inlet (P+1 and P-1 input corresponding to the first power supply P1, and P+2 and P-2 input corresponding to the second power supply P2). The available voltage standard of the power supply is supported from 12VDC to 52VDC

DIGITUS DN-651136 Industrial Ethernet PoE Switch - Fig
9

Packages

Content QTY
Industrial switch 1 PCS
User manual 1 PCS

This is a Class A product. In home environment, this product may cause radio interference. In this case, the user may be required to take appropriate measures.
Hereby Assmann Electronic GmbH, declares that the Declaration of  Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address.

www.assmann.com
Assmann Electronic GmbH
Auf dem Schüffel 3
58513 Lüdenscheid,
Germahy

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals