inELS RFDEL-71B-SL Universal Dimmer Instruction Manual

June 4, 2024
inELS

inELS RFDEL-71B-SL Universal Dimmer

inELS RFDEL-71B-SL Universal Dimmer-fig1

WARNING

  • Newly produced drivers work in the RFIO2 data protocol mode.

  • These drivers are loaded in the actuators in a different way than be-fore. Among other things, it eliminates the risk of inadvertently loading another randomly occurring controller within range. Drivers can still be switched to so-called compatibility mode, and loaded in a simpler (older way).

  • The mode in which the controllers are working is changed and indicated after 8-second pressing of the ‘Prog’ button. The LED diode under the pushbutton is on when the button is kept pressed; after 8 seconds it indicates the chosen mode by different flashing intervals. The mode changes to the inverse mode after each pressing of the button.

  • RFIO2 mode
    = Double flash (flash, flash, gap, flash, flash)

  • Compatibility mode
    = Flash fast (flash, flash, flash, flash, flash)

  • Update the controller actuators in RFIO2 mode

  • If the controller is used in RFIO2 mode, then to update the controller actuators, it is necessary to switch not only the actuator to the update mode (according to the instructions for the actuator), but also the controller in the following way:

    • Press the programming button on the controller, converter for more than 1 second and release it.
    • The LED diode starts fl ashing in second intervals. Leave the LED fl ashing
    • activate the programming mode on the actuator by pressing the programming button for more than 1 second. The actuator is also put into the programming mode.
    • The desired function can be selected by the respective number of pressing of the control pushbuttons or inputs (of the converter).
    • The programming modes on the controller and actuator can be closed by pressing the programming button for less than 1 second. The LEDs stop fl ashing.

inELS RFDEL-71B-SL Universal Dimmer-fig2

Characteristics

  • The universal built-in dimmer is used to regulate light sources:
    • R – classic lamps.
    • L – halogen lamps with wound transformer.
    • C – halogen lamps with electronic transformer.
    • ESL – dimmable energy-efficient fluorescent lamps.
    • LED – LED light sources (230V).
  • They can be combined with detectors, controllers, iNELS RF Control or system components.
  • The BOX design lets you mount it right in an installation box, a ceiling or light cover. 7 light functions – smooth starting up or running out with time setting 2 sec to 30 min + additional function SWITCH OFF
  • Setting of minimum brightness eliminates blinking of LED and ESL light sources
  • Universal dimmer may be controlled by up to 25 channels
  • Control input “S” for connection of the existing wired pushbutton
  • Programming pushbutton on the element can also be used as manual control of the output
  • For the elements marked as iNELS RF Control2 (RFIO2), it is possible to set the function• For com-ponents labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
  • Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
  • Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).

Assembly

  • mounting in an installation box (even under the existing button / switch)

  • mounting into a light cover

  • ceiling mounted

Connection

Screwless terminals

inELS RFDEL-71B-SL Universal Dimmer-fig7

Radio frequency signal penetration through various construction

materials

inELS RFDEL-71B-SL Universal Dimmer-fig8

For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures

Indication, manual control

inELS RFDEL-71B-SL Universal Dimmer-fig9

  • LED STATUS – indication of the device status.
  • Manual control is performed by pressing the PROG button for less than 1s.
  • Programming is performed by pressing the PROG but-ton for more than 1s.
    In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.

Compatibility

  • The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2.
  • The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.

Programming with RF control units

The address listed on the front of the actuator is used for programming and controlling actua-tors by RF control units.

SETUP mode (load type selection and minimum brightness setting)

Load type setting and minimum brightness setting

  • Switching over to the SETUP mode can be carried out by quick fourfold click on the programming push button.
  • (4x PROG < 1s)
  • The choice of the load type is the fi rst function of the SETUP mode. In this mode the output brightness changes automatically between 0% and 100% and the LED on the instrument indicates the actually chosen load type:
    • R, C mode – fourfold fl ash
    • L mode – double fl ash
  • The mode can be changed to the inverse mode by pressing the push button on any controller that is already learned.
  • Setting of minimum brightness is the other function of the SETUP mode. This function can be chosen by short pressing the PROG push button. This mode is indicated by the same blinking mode as the learning mode (LED blinking 1x per second). Minimum brightness can be set using any already learned controlled. Another short pressing the PROG push button closes the SETUP mode and the preset type of the load and minimum brightness are saved into memory.

Functions and programming with RF transmitters

Light scene function 1
  • Description of   light scene **1

**

  * By pressing the programmed button for less than 0.5s, the light illuminates; it goes out by pressing again.
  *  By pressing the programmed button for more than 0.5s, fl uid brightness regu-lation will occur. After releasing the button, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on /off to this intensity.
  * It is possible to readjust the change in intensity at any time by a long press of the programmed button.
  • **Programming

**inELS RFDEL-71B-SL Universal Dimmer-fig13

Light scene function 2
  • **Description of light scene 2

**

  * By pressing the programmed button for less than 3s, the light illuminates; it goes out by pressing again.
  * In order to limit undesirable control of brightness, fluid brightness control occurs only by pressing a programmed button for over 3s. After releasing the but-ton, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on / off to this intensity.
  * It is possible to readjust the change in intensity at any time by pressing the programmed button for over 3s.
  • Programming

inELS RFDEL-71B-SL Universal Dimmer-fig15

Light scene function 3
  • **Description of light scene 3

**

  * By pressing the programmed button for less than 0.5s, the light fluidly illuminates for a period of 3s (at 100% brightness). By pressing the button shortly again, the light will continuously switch off for 3 seconds.
  * By pressing the programmed button for more than 0.5s, fluid brightness regulation will occur. After releasing the button, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on /off to this intensity.
  * It is possible to readjust the change in intensity at any time by a long press of the programmed button.  

The actuator remembers the adjusted value even after disconnecting from the power supply.

inELS RFDEL-71B-SL Universal Dimmer-fig16

  • **Programming

**inELS RFDEL-71B-SL Universal Dimmer-fig17

Light scene function 4
  • **Description of light scene 4

**

  * By pressing the programmed button for less than 0.5s, the light illuminates. By pressing the button shortly again, the light will continuously switch off for 3 seconds (at 100% brightness).
  * By pressing the programmed button for more than 0.5s, fluid brightness regulation will occur. After releasing the button, the brightness level is saved in the memory, and pressing the button shortly later will switch the light on/off to this intensity.
  * It is possible to readjust the change in intensity at any time by a long press of the programmed button.  

The actuator remembers the adjusted value even after disconnecting from the power supply.

inELS RFDEL-71B-SL Universal Dimmer-fig18

  • **Programming

**inELS RFDEL-71B-SL Universal Dimmer-fig19

Function sunrise
  • **Description of sunrise function

**
After pressing the programmed button, the light begins to illuminate in the pro-grammed time interval in a range of 2 seconds to 30 minutes.

  • **Programming

inELS RFDEL-71B-SL Universal Dimmer-fig21

**
inELS RFDEL-71B-SL Universal Dimmer-fig22

Function sunset
  • **Description of sunset function

**
After pressing the programmed button, the light begins to dim in the pro- grammed time interval in a range of 2 seconds to 30 minutes.

  • Programming

inELS RFDEL-71B-SL Universal Dimmer-fig21
inELS RFDEL-71B-SL Universal Dimmer-fig22

Function ON/OFF
  • **Description of ON/OFF

**
If the light is switched off , pressing the programmed button will switch it on. If the light is switched on, pressing the programmed button will switch it off .

  • **Programming

**inELS RFDEL-71B-SL Universal Dimmer-fig24

Function switch off
  • Description of switch off

The dimmer output switches off by pressing the button.

  • Programming

RFDEL

Delete actuator

Deleting one position of the transmitter


  • By pressing the programming button on the actuator for 5 sec-onds, deletion of one transmitter activates. LED fl ashs 4x in each 1s interval.
  • Pressing the required button on the transmitter deletes it from the actuator’s memory.
  • To confi rm deletion, the LED will confi rm with a fl ash long and the component returns to the operating mode.

Deleting the entire memory

  • By pressing the programming button on the actuator for 8 sec-onds, deletion occurs of the actuator’s entire memory. LED fl ashs 4x in each 1s interval.
  • The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.).
  • You can return to the operating mode by pressing the Prog but-ton for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode.

Control with external button

The function for the external “wired” pushbutton can be assigned in the same way as for the wireless pushbutton, i.e. by pressing the programming pushbutton on the actor and respective number of control pushbutton pressings.

Additional information

  • Do not mix more types of light sources!
  • Do not try to use energy saving bulbs that are not labeled as dimmable!
  • Incorrect setting of the type of light source aff ects the extent and dimming (but no damage to the dimmer or load).
  • Incorrect setting of the type of load can cause overheating of dimmer.
  • Maximum number of light sources depends on their internal structure.

Warning

  • Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifi cation upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control

  • ELKO EP declares that the RFSG type of equipment complies with Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU
    Declaration of Conformity is at: https://www.elkoep.com/wireless-contact- converter-230v—rfsg-1m

  • ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
    Tel.: +420 573 514 211, e-mail: [email protected], www.elkoep.com

Technical parameters

Supply voltage:| 230 V AC|
---|---|---
Supply voltage frequency:| 50-60 Hz|
Apparent power:| 5 VA / cos φ = 0.1|
Dissipated power:| 0.5 W|
Supply voltage tolerance:| +10/ -15 %|
Connection:| 4 – wire, with NEUTRAL / 4-vodičové, s “NULOU“|
Output|  |
Dimmed load:| R, L, C, LED, ESL|
Contactless:| 2 x MOSFET|
Load capacity:| max. 300 W|
Control|  |
Wireless:| up to / až 25 kanály|
Communicationprotocol:| RFIO2|
Frequency:| 866-922 MHz|
Repeaterfunction:| yes / ano|
Range:| až 200 m|
Manualcontrol:| tlačítko PROG (ON/OFF)|
External button / switch:| yes / ano|
Other data|  |
Operating temperature:| -15 až + 45 °C|
Working position:| any / libovolná|
Mounting:| free at lead-in wires / volné na přívodních vodičích|
Protection:| IP40|
Overvoltage category:| III.|
Contamination degree:| 2|
Connection:| screwless terminals / bezšroubové svorky|
Connecting conductor:| 0.2-1.5 mm2 solid/flexible|
Dimensions:| 43 x 44 x 22 mm|
Weight:| 30 g|
Related standards:| Související normy:| EN 60730, EN 63044, EN 300 220, EN 301 489

  • loadability of power factor cos φ=1
  • Power factor of dimmable LED and ESL bulbs moves in following range: cos φ = 0.95 to 0.4.
  • Aproximate value of maximal load is achieved by multiplication of loadability of dimmer and power factor connected to a light source.
  • Attention:
    • When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
    • Between the individual commands must be an interval of at least 1s.

ABOUT COMPANY

  • ELKO EP, s.r.o.
  • Palackého 493
  • 769 01 Holešov, Všetuly
  • Česká republika
  • e-mail: [email protected]
  • EN Support: +420 778 427 366
  • CZ Technická podpora: +420 775 444 609
  • www.elkoep.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

inELS User Manuals

Related Manuals