General
These installation instructions include instructions for use and safety instructions. Please read the instructions carefully and note the regulations and relevant information before putting the device into operation. Please keep these installation instructions in a safe place for later use.
Intended use
The LED coop lighting illuminates the coop, customized to individual settings. About the SmartCoop control unit (Item 70600) The lighting can be switched on and off manually by pressing a button. In automatic mode, the control unit automatically calculates the required lighting period, according to the defined night duration and the season-specific light conditions.
Misuse of the system for other purposes is not permitted. In the event of incorrect use or modifications to the device, the manufacturer’s liabilities are forfeited.
Safety instructions
Caution
Risk of physical injury and material damage if used incorrectly.
-
Cables must not be crushed or twisted. Fire risk from short circuit.
-
All electrical supply lines must be routed so that they are protected from the risk of being pecked and are not accessible to animals. Use only peck-proof materials.
-
The cable for the product cannot be replaced. If damage occurs to the cables, the product must be scrapped.
-
Up to three lighting modules can be daisy-chained together.
Do not connect more modules than this to the system. -
For connecting, use only the original cables, and do not modify them.
-
Do not shorten cables or connect them, except by using plug-in connections.
-
The module must be operated only with the SmartCoop control unit (item 70600).
Scope of delivery and accessories
Scope of delivery
1. LED coop lighting | 2. Fastening screws (2x) |
---|
1 Casing
2 Connection cable 100 cm
3 Connection plug|
Accessories:
- Item 70600 SmartCoop control unit
- Item 70629 Extension cable 2 m
- Item 70630 Extension cable 4 m
Technical data
Connection cable length 100 cm
Ingress protection rating IP30
Supply voltage 12 V DC
Power consumption 1.5 W
Lumen output 120 lumens
Colour temperature 3000K warm white
Installation
We recommend one LED coop lighting unit per 2 m2 of surface to be illuminated. Depending on the coop size, a maximum of 3 LED coop lighting units can be connected in series.
Positioning:
The LED coop lighting modules can be connected in series. Just one connection
plug is connected to the control unit; further lighting modules are plugged
into the presently final module.
Please comply with the cable length (100 cm) when selecting a location.
Wherever possible, we recommend that those areas of the coop are illuminated
in which the chickens spend time during the day (especially feeding and
drinking locations). However, the perches do not have to be illuminated.
Installation steps:
-
Remove the clipped-on cover of the LED coop lighting unit, and attach the back part to the selected location in the coop, using the attachment set included in the delivery.
a. When laying the surface-mounted connection cables, they can be led in and out through the side of the casing.
b. When laying the connection cables concealed in the wall/ ceiling, the cables can be led in and out towards the inside.
c. Then replace the cover. -
If two LED coop lighting modules are to be deployed:
a. Remove the bridging plug from the first lighting mode, and insert the second module into the plug-in location which has become available.
b. Attach the second lighting mode in its selected coop location, using the attachment set included in the delivery. Ensure that the cable length is sufficient. -
If a third LED coop lighting module is to be deployed → Proceed as described in 2. A bridging plug must always be plugged into the final module, otherwise the lighting will not work.
-
Lead the connection cable for the LED coop lighting from below through the cable slot in the rear part of the control unit, and connect it to the intended plug-in location for the module (03 – COOP LIGHTS). Please comply with the information in the operating instructions for the control unit in section 6.3 Installing and Connecting the Modules.
If the connection cable built into the module is not long enough, it can be lengthened using extension cables (items 70629, 70630). Ensure that the connection location is protected from water and dust. The module cable must have only a single extension.
Calibration and configuration
Configure the LED coop lighting. The exact procedure is describe in the operating instructions for the control unit (item 70600) in section 10 Connecting the Modules.
Maintenance and care
The LED coop lighting is maintenance-free. In the event of heavy contamination, the front can be cleaned using a damp cloth.
Disposal
Electrical waste
It is up to the operator to dispose of the device responsibly after its useful
life in accordance with local regulations. Consult the relevant regulations
for your country. The device must not be disposed of in household waste. Under
the terms of the EU Directive on the disposal of old electrical and electronic
equipment, the unit can be taken to local authority-run refuse sites or
recycling plants free of charge, or returned to dealers who offer a returns
service. Correct disposal protects the environment and prevents any possible
harmful impacts on humans and the environment.
INFO: The operating instructions for the SmartCoop control unit and the installation instructions for the SmartCoop modules are available to download at: www.kerbl-smartcoop.com
References
- Home - www.austria.at
- France.fr : Explore France and its wonders - Explore France
- Everything around animal breeding, husbandry and agricultural supplies - Albert Kerbl GmbH
- Page d'accueil - Kerbl France
- Suche - Albert Kerbl GmbH
- Home - Kerbl UK Ltd
- Everything around animal breeding, husbandry and agricultural supplies - Albert Kerbl GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>