Maxxima MEW-USB30PD USB Power Delivery Type C and QC 3.0 Type A Charger with 15A Tamper Receptacle Instruction Manual
- June 9, 2024
- Maxxima
Table of Contents
MEW-USB30PD USB Power Delivery Type C and QC 3.0 Type A Charger with 15A
Tamper Receptacle
Instruction Manual
MEW-USB30PD USB Power Delivery Type C and QC 3.0 Type A Charger with 15A
Tamper Receptacle
RECEPTACLE RATING | 15 AM P 12 5VAC 6 0Hz |
---|---|
USB RATING | Single USB output: 5V 3A, 9V 3A, 12V 2.5A, 15V 2A, 20V 1.5A |
Two USB output total 5V 3.6A
USB COMPATIBILITY| USB 1.1/2.0/3.0/3.1 Devices
WIRE TERMINALS| #14-#12(15A) AWG Copper
OPERATING TEMP| -4to 14 0 °F(-2 0 to 6 0 °C)
RECEPTACLE DIMENSION| 4.0 7×1.6 8 x1.70 inch
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference,and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and f ound to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,theuserisencouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device is to be installed in an outlet box that measures at least
3inx2inx2.5in and wired in accordance with NEC article 314 box fill
requirements.
CAUTION:
- This device is to be used with Class 2 USB connectors and interconnecting cables.
- The Class 2 usb ports are not intended to physically support products or appliances.
- The Class 2 usb cables must be routed away f rom the 120V receptacles and inserted plugs.
- This device is to be used with copper or copper clad wire only.
CAUTION:
To reduce the risk of fire and overheating, check for compatibility with the
appliance manufacturer’s charging instructions.
PARTS INCLUDED
WARNING: This product may represent a possibleshockorfire hazard if
improperly installedorattachedinanyway.Productshouldbeinstalledinaccordance
with theownersmanual, current electrical codesand/or the current National
ElectricCode(NEC).
RISK OF ELECTRIC SHOCK: TURN OFFTHE MAIN POWERAT THE CIRCUIT BREAKER
BEFORE INSTALLING.
RISKOFFFIRE:
- DO NOT EXCEED ELECTRICAL RATINGS
- USE INDOORS ONLY
TAMPER RESISTANT RECEPTACLES
Built-in shutter keeps children safe.
Installation
WARNING: SHOCK HAZARD. MAY RESULT IN SERIOUSINJURY OR DEATH. TURN
OFFPOWERAT CIRCUIT BREAKER BEFOREINSTALLING.
IF YOU’RE UNFAMILIAR WITH PROPER ELECTRICAL WIRING OBTAIN THE SERVICES OF A
QUALIFIED PERSON.
-
TURN POWER OFF Turn power off at circuit breaker or remove fuse.
-
REMOVE EXISTING OUTLET
Take off wall-plate and outlet by removing mounting screws. Carefully pull out outlet fromwall. Label wires connected to existing outlet box and disconnect wires. -
STRIP WIRES
Strip wires to y, inch if necessary. Use with #14 or #12 AWG copper or copper clad wire. READ AND SAVE THESE INSTRUCTIONS -
WIRE YOUR NEW OUTLET
Wire device as shown below. Use a screwdriver to secure wires to terminals. (Tighten every screws and have no bare conductors exposed, l2inch.pounds (1.4N.m)of torque.)
WIRE WITH ONE HOT AND ONE NEUTRAL.
WIRE WITH TWO HOT AND TWO NEUTRAL.
-
INSERT OUTLET INSIDE THE OUTLET BOX
• Position all wires inside the outlet box with care, leaving enough roomto insert the device.
• Use provided mounting screws to attach the device securely inside the outlet box.
-
INSTALL WALL PLATE
-
TURN POWER ON
Turn power on at circuit breaker or replace the fuse.
Note:This outlet only has 30W PD when the USB-C port is used on its own and QC 3.0 when the USB-A port is used on its own. When both ports are occupied, the ports output 5V, 3.6A total.
1 YEAR WARRANTY
Maxxima extends a 1 year limited warranty to the original purchase that the products listed are free from defects in material and/or workmanship only. Maxxima will replace any warrantied product to the original consumer/purchaser if the product fails because of defects due to workmanship and/or materials within the limited warranty period. Limited warranty is not transferable and applies to the original installation of the Maxxima product. This offer does not constitute in any way a product guarantee and Maxxima does not hereby assume any obligation whatsoever beyond sending a free replacement product.