GENMAX 5250 Running Watts Portable Inverter Generator Instruction Manual

June 9, 2024
GENMAX

5250 Running Watts Portable Inverter Generator
Instruction ManualGENMAX 5250 Running Watts Portable Inverter
Generator

GM6000XiE
Portable Inverter Generator
5250 Running Watts | 6000 Peak Watts

5250 Running Watts Portable Inverter Generator

WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety. Operation, maintenance and storage of this product. Before use, read carefully and understand all cautions,  warnings, instructions and product labels. Failure to do so could result in serious personal injury and/or property damage.

California Proposition 65 Warning
The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects or other reproductive harm.
DISCLAIMERS:
All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are  intended as representative reference views only.
Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product,  service or maintenance improvement. We reserve the right to make any change at any time without notice. Some images may vary depending upon which model is shown.
ALL RIGHTS RESERVED:
No part of this publication may be reproduced or used in any form by any means – graphic, electronic or mechanical, including photocopying, recording, taping or  information storage and retrieval systems – without the written permission of CHONGQING DINKING POWER MACHINERY CO., LTD

DANGER
This manual contains important instructions for operating this inverter generator. For your safety and the safety of others, be sure to read this manual thoroughly before  operating the generator. Failure to properly follow all instructions and precautions can cause you and others to be seriously hurt or killed.

UNPACKING

CAUTION
****Always have assistance when lifting the generator. The generator is heavy; lifting it could cause bodily harm.
Avoid cutting on or near staples to prevent personal injury.

Tools required – box cutter or similar device.

  1. Carefully cut the packing tape on top of the carton.
  2. Remove socket wrench, oil and funnel and save for later.
  3. Carefully cut two sides of the carton to remove the generator.

WHAT COMES IN THE BOX
Spark Plug Socket Wrench (1)
Dual-Purpose Screwdriver (1)
User Manual (1)
Warranty Information (1)
Funnel (1)
Duplex plug (1)
Four-prong plug (1)

LIMITED WARRANTY

  1. DURATION : One (1) year from the date of purchase by the original purchaser ( retail customer ) on products used solely for consumer applications; if a product is used for business, commercial, or industrial applications, the warranty per iod will be limited to ninety (90) days from the date of purchase.

  2. WHO GIVES THIS WARRANTY (WARRANTOR): CHONGQING DINKING POWER MACHINERY CO., LTD

  3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than for purposes of resale) of the Genmax’s inverter.4. WHAT PRODUCTS  ARE COVERED BY THIS WARRANTY: Any portable generator supplied or manufactured by Warrantor.5. WHAT IS COVERED UNDER THIS WARRANTY:  Substantial defects on material and workmanship which occur within the durat ion of the warranty period.

  4. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Transportation changes for s ending the product to Warrantor or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer.
    B. Damages caused by abuse, accident, shipping, misuse, overloading, modification, and the effects of corrosion, erosion and normal wear and tear.
    C. Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations set forth in the owner’s  manual(s), or if the product is used as rental equipment.
    D. Pre-delivery service, i.e. assembly, oil or lubricants, and adjustment.
    E. Items or service that are normally required to maintain the product, i.e. lubricants and filters.
    F. Warrantor will not pay for repairs or adjustments to the product, or for any costs or labour, performed without Warrantor’s prior authorization.
    EXCLUSIONS AND LIMITATIONS : Warrantor makes no other warranty of any kind, express or implied. Implied warranties, including warranties of merchantability  and of fitness for a particular purpose, are hereby disclaimed. This warranty service described above is the exclusive remedy under this warranty; liability for incidental  and consequential damages is excluded to the extent permitted by law.

  5. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
    A. The purchaser must provide dated proof of purchase and must notify Warrantor within the warranty period.
    B. Deliver or ship the serviced generator or component to the nearest Warrantor’s authorized service representative.
    Freight costs, if any, must be norne by the purchaser.

  6. HAVE QUESTIONS?

Email: warrantiessmallengines@gmail.com
Phone: 866-960-2920

WARRANTY CARD

Name: ___
Street Address: _

City, State, ZIP:
Country: ____
Phone Number:

E-Mail: ___
Model Number: _

Serial Number: ____
Date Purchased:
Purchased From:

SAFETY WARNING

****Personal and property safeties of you and others are very vital. Please read the Safety Warning in the User’s Manual and the decals of the generator set carefully. The Safety Warning can alert you to those potential hazards that could harm you and others. In front of each Safety Warning, there is one of four words “DANGER” “WARNING”, “ATTENTION”, and “CAREFUL”. Details are as follows:

DANGER
Failure to follow the instruction will result in being in peril of your life or extremely serious injury.
WARNING
Failure to follow the instruction will result in being in peril of your life or very serious injury.
CAREFUL
Failure to follow the instruction will result in minor injury.
ATTENTION
Failure to follow the instruction will result in the damage to your generator set and other properties.

CO TECHNICAL WARNING
CO DETECT technology monitors the accumulation of carbon monoxide (CO), a poisonous gas produced by engine exhaust when the generator is running. If CO Sensor  detects unsafe elevated levels of CO gas, it automatically shuts off the engine. CO Sensor is not a substitute for an indoor carbon monoxide alarm or for safe operation. DO  NOT allow engine exhaust fumes to enter a confined area through windows, doors, vents or other openings. Generators must ALWAYS be used outdoors, far away from  occupied buildings with engine exhaust pointed away from people and buildings. Meets the requirements of ANSI/PGMA G300-2018.
NEUTRAL FLOATING
For portable generators where the neutral is floating, the operator’s manual shall include the following wording or equivalent:
The portable generator stator winding is isolated from the frame and from the AC receptacle ground pin; and Electrical devices that require a connection between one  conductor pin and the grounded receptacle pin may not function properly.

SAFETY INSTRUCTIONS

Before operating the generator, it will help you avoid accidents to read and understand the Manual and familiarize yourself with the safe operation procedures of the generator. GENMAX 5250 Running Watts Portable Inverter
Generator - Figrue 1

SAFETY LABELS AND DECALS

GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
2GENMAX 5250 Running Watts Portable
Inverter Generator - Figrue 3

NAMES OF COMPONENTS

GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
4

INSTALLATION OF WHEELS AND HANDRAILS

Install Support Foot

  1. Align the two holes on the support seat with the two holes on the bottom of the frame. Place two bolts through the support seat hole and the frame hole;
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
5

  2. Fasten the nut to the bolt, tighten with a wrench.
    Install the other side in the same way.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
6

Install the Wheel

  1. Pass the axle through the wheel, connect to the rack;
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
7

  2. Insert the R pin into the hole in the wheel shaft. Install the other side in the same way.

Install Handrails

  1. Bolt the handle to the frame;

  2. Fasten the nut to the bolt, tighten with a wrench. Install the other side in the same way.

CONTROL FUNCTIONS

GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
12

CONTROL PANEL FEATURES GM6000XiE

  1. 120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): The outlet is capable of carrying a maximum of 20 amps.
  2. USB Duplex: 5V DC that come in 1 amps and2.1 amps.
  3. Reset: If the inverter is overloaded, the reset breaker will trip. The engine will continue to run, but there will be no output from the inverter. Unplug the devices and  reduce the load. Push in the reset breaker to reset it.
  4. Low Idle: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel.
  5. Ground Terminal: The ground terminal is used to externally ground the inverter.
  6. Low Oil Alarm: Indicates low oil level.
  7. Overload Alarm: Indicates that the inverter is overloaded.
  8. Power Indicator: Indicates the inverter is ready to be used.
  9. 120/240-Volt, 30-Amp Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps.
  10. Circuit Protector: If the inverter is overloaded, the reset breaker will trip to block current.
  11. Hours: Total time of generator use.
  12. CO Alarm: Flashing red light: dangerous levels of carbon monoxide gas have built up leave immediately until area has aired out. Move generator to wellventilated area  before operation. Flashing yellow light: carbon monoxide sensor malfunction. Sensor needs service.
  13. Engine Switch: Manage battery power and shutdown.
  14. Choke Switch: when cold start, properly close part of the air inlet to improve the engine start performance, after normal operation, the choke should be fully open, otherwise the engine can not run properly because of too thick mixture and cause too much oil consumption.

PREPARATIONS

DANGER

  • Fuel is flammable and toxic, please read the Safety Instruction carefully before refueling;
  • Do not fuel too full, otherwise fuel will spill after fuel tank is warmed;
  • After refueling, confirm that the fuel tank cap has been tightened.

ATTENTION

  • After refueling, dry gasoline residue with a clean and soft cloth in time to avoid damaging plastic enclosure;
  • Unleaded gasoline must be used, as leaded gasoline can seriously damage internal parts of the generator;

Remove the tank cap and add gasoline.
Fuel tank capacity: 3.8gal

Oil
No oil is filled into this generator when being delivered. Do not start up the generator without filling sufficient oil.

  1. Please place the generator onto a horizontal plane surface;

  2. Unscrew oil dipstick, Fill in 0.21gal oil (SAE 10W/30 oil is recommended, of which the grade is API standard Type SE or higher);
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
14

  3. Tighten the oil dipstick.

Pre-use Inspection
WARNING
Even if the generator is not in service, its important component may suddenly fails. Before the generator is started up, if any of following components is unable to work  properly, please inspect and repair carefully.

Tip: The condition of the generator shall be inspected before using every time.
Pre-operation inspection
Fuel

  • Check fuel level in fuel tank of the generator, and fuel it if necessary.

Oil

  • Check oil level of the generator, and fill oil if necessary;
  • Check whether there is oil leaking.

Abnormal conditions during operation

  • Check operating condition of the generator;
  • If there is any need, please do not hesitate to consult your dealer.

STARTING UP THE GENERATOR

  1. Remove the load from all output ends;

  2. Connect battery line before first use:
    1. Unscrew the bolt on the negative electrode of the battery;
    2. Install the negative wire through the bolt to the battery;
    3. The positive wire is installed in the same way.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
15

  3. Turn fuel switch to “ON” position;

  4. Press LOW IDLE to “OFF”;

  5. Pull the choke out;
    Tip: There is no need to pull out the damper when the engine is started in warm state.

  6. Select Boot Mode:
    a. Hand Starting:
    1. Press the engine switch to move up the middle position “ON”;
    2. Pull the starting handle to start the generator.
    b. Electric Start: Press the engine switch upward to the Start position “Start” for 2-3 s.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
19

  7. After starting push the choke in;

  8. Plug in after started.

SHUTTING DOWN THE GENERATOR

  1. Unplug the power cord;

  2. Press main switch to “OFF” position;

  3. Turn fuel switch to “OFF” position.

USING THE GENERATOR

Service environment of the generator

  • Applicable temperature: -5°C~ 40°C;

  • Applicable humidity: below 95%;

  • Applicable altitude: regions below 1,500 m (It shall be used by reducing power in regions above 1,000 m).

  • Standard atmospheric condition

  • Ambient temperature Tr: 298k (25°C)

  • Relative air humidity Фr: 30%

  • Absolute atmospheric pressure Pr: 100kPa
    When actual environmental condition is inconsistent with the condition of output power of the generator set:

  • Every 5°C of increase in ambient temperature will reduce the power of generator by about 2%.

  • Every 30% of increase in relative humidity of air will reduce the power of generator by about 1.5%.

  • Every 300 m rising of ASL will reduce the power the generator by about 4.5%.

Generator wiring

  • When the generator is connected to household power source as a backup power supply, the connection shall be carried out by a professional electrician or a person  familiar with electricity.

  • After connecting the load to the generator, check carefully whether electrical connection is safe and reliable.
    Improper electrical connection may cause generator damage, burning or fire.

  • Avoid connecting this generator to commercial power outlet.

  • When extending the cable, be sure not to exceed its length.
    ① 60m cross-section area is 1.5mm²
    ② 100m cross-section area is 2.5mm²

  • The appearance of extension cable shall be protected by a layer of tough and elastic rubber cover (IEC25) or other substitutes.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
24

Connection of AC power
WARNING
All electrical equipment shall be disconnected before inserting the plug.

ATTENTION

  • Make sure that all electrical equipment, including wires and plugs, are in good condition before connecting to the generator;
  • Make sure that all loads driven by the generator are within rated load range;
  • Make sure that load current is within rated current range of rated socket.
    Tip: Make sure that the generator set is grounded, and if electrical equipment requires grounding, the generator set must be grounded.
    ① Start up the engine;
    ② Turn energy-saving switch to “ON”;
    ③ Insert the plug into AC outlet;
    ④ Make sure that AC indicator is lit up;
    ⑤ Switch on electrical equipment.
    Tip: Before increasing engine speed, energysaving switch must be switched to “OFF”. If the generator set supplies power to multi loads or electrical equipment, start  from large to small according to the size of each electrical equipment.

Generator grounding
In order to prevent any damage to the generator caused by electric shock or improper electrical application, it is recommended that the generator is grounded with good conductor with insulating sheath.

  1. Please use grounding wire with sufficient electrical energy capacity;
  2. Connect one end of grounding wire reliable to grounding bolt on control panel of the generator set;
  3. Insert grounding body (iron rod with a diameter of 5 ~ 10mm) 200mm below into the earth and lead it out with conductor;
  4. Connect the other end of the grounding wire reliable to the led wire of grounding body.

SERVICE AND MAINTENANCE

Good maintenance and service is the best guarantee for safe, economical and zero-failure operation. It also contributes to environmental protection.
In order to keep the generator in good condition, you must inspect and maintain it regularly. The maintenance schedule is as follows:

Maintenance cycle
Item| Each| First in 1 month
20 hours ours| Then every three
months or every
50 hours| 100 hours per year or use
---|---|---|---|---
Engine oil| Check-fill| | | |
Replace| | | |
Gearbox gear Oil (if any)| Check oil| | | |
Replace| | | |
Air cleaner| Inspection| | | |
V| Clean lean| | |
Replace| | | |
Settling cup (if any)| Clean| | | |
Spark plug| Clean-adjust| | | |
Spark eliminator| Clean| | | |
Idle speed (if any)”| Check-adjust| | | |
Valve clearance*| Check-adjust| | | |
Fuel tank and fuel filter”| Clean| | | |
Fuel line| Inspection| Every two yeara (Please replace if ecessary)
Cylinder head, piston| Remove carbon deposit**| Displacement < 225cc, every 125 hours; displacement capacity a. 225cc, every 250 hours.

  • These items shal be replaced if necessary;
    ** These items shall be maintained by the dealer authorized by the Company, unless the user has proper tools and maintenance ability.

ATTENTION

  • If it often works under high temperature or high load, oil shall be changed every 25 hours;
  • If it often works in dusty or harsh environment, air cleaner element shall be cleaned every 10 hours. If necessary, the air cleaner element shall be replaced every 25 hours;
  • It shall be maintained on spot-inspection cycle and time, whichever is earlier;
  • If maintenance cycle time has elapsed, perform the maintenance as soon as possible as per the table above.

WARNING
Please shut down the engine first before performing any maintenance. The engine shall be placed in a horizontal position. In order to prevent the engine from starting up,  separate spark plug cap shall be separated from spark plug.
Do not use it indoors or use it in a tunnel, cave or other places ventilated poorly. Make sure that work area is well ventilated. Exhaust gas from the engine contains toxic gases, carbon oxides, and the inhalation can cause shock, loss of consciousness, and even death.

Spark plug inspection
Spark plug is an important part of the generator, which must be inspected regularly.

  1. Remove the high voltage assembly;

  2. Insert the screwdriver into the sleeve, to screw it counterclockwise, and then remove the spark plug;

  3. Check whether there is discoloration, and remove carbon deposits.Check whether there is little pale to moderate brown on ceramic cores around center electrode of the  spark plug;

  4. Check the model of spark plug and clearance.
    Standard spark: BPR6ES
    Spark plug gap: 0.7-0.8mm
    Tip: The spark plug clearance is required to be measured by line thickness gauge, which shall be adjusted if necessary.

  5. Install the spark plugs in reverse order of removalSpark cold torque: 22.5±2.5 N.m

Tip: If there is no torque wrench when installing the spark plug, a better estimation method is to screw it 1/4-1/2 turns by force after screwing it in place, but the spark plug  shall be screwed to specified torque as soon as possible.

Adjustment of the carburetor
The carburetor is an important components of the engine. The adjustment shall be carried out by a dealer with professional knowledge, professional data and equipment, to ensure that the adjustment is proper.

Replacement of oil
WARNING
Do not drain the oil immediately after turning off the generator. Oil temperature is very high, when operating, take care to avoid scalding.

  1. Put the generator on a horizontal surface, start the generator, run it for a few minutes to increase its temperature, and then turn off the engine;

  2. Unscrew oil dipstick;

  3. Place the container and tilt the machine to drain the oil;

  4. Refill oil to a proper level, tighten oil dipstick, cover external cover plate and tighten the knob. Recommended oil: SAE S10W/30 Oil grade: API standard Model SJ or  higher Volume: 0.21gal
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
34

Air filter
Dirty air cleaner may prevent air from flowing into the carburetor. In order to prevent failure of the carburetor, please maintain air cleaner regularly. If being used in a dusty  environment, it shall be maintained frequently.

  1. Remove screws, to remove cover plate of air cleaner ;
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
35

  2. Clean foam cleaner element with cleaning solvent and blow it dry, Put a few drops of oil on the filter element;
    ATTENTION
    Be sure not to twist the foam cleaner element forcibly to avoid damage.

  3. Put foam cleaner element into air cleaner;
    Tip: Make sure that the surface of foam cleaner element is in close contact with air cleaner, and there shall be no gap leaking air. Be sure not to start the engine before air  cleaner is assembled, because it will generate excessive toxic gas and wear the cylinder;

  4. Reassemble empty air cleaner cap back to original position, and tighten screws.

  5. Fuel filter screen

WARNING
Be sure not to open fuel tank of the generator in a place where smoking or with flame.

  1. Remove fuel tank cap and fuel tank filter screen.
  2. Clean fuel tank filter screen with gasoline.
  3. Wipe filter screen dry, and put it back into fuel tank.
  4. Reassemble fuel tank cap.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
39

ATTENTION
Be sure to screw fuel tank cap tight.

STORAGE AND TRANSPORT

Generator storage
If it is stored long-term, in order to prevent aging, you shall take some storage measures.

  1. Follow the shutdown steps to shut down the generator.

  2. Open fuel tank cap, to take out fuel filter screen.
    Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel tank cap back.
    GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
40

  3. Start up the engine to burn off fuel in the carburetor, and then shut it down.
    Tip: Do not connect any electrical equipment. Running time of the engine depends on remaining fuel in the fuel tank.

  4. Locate the carburetor to drain the remaining gasoline and place a suitable container to capture the emitted fuel.

  5. Loosen the carburetor drain screws until you see fuel draining from the carburetor.

  6. Allow fuel to drain into the container and tighten the drain screws on the carburetor.

  7. Unscrew oil dipstick, and drain oil in the crankcase off. Fill new oil to upper oil limit, and then assemble oil dipstick.

  8. Gently pull startup handle until you feel resistance, allowing both inlet valve and exhaust valve to be closed.

  9. Disconnect the battery cable.

  10. Place the generator set in a clean and dry area.

Generator transport

  • When the generator set is transported, it shall be ensured that there is no fuel spilling;
  • Do not fill excessive fuel into fuel tank;
  • Do not run the generator, and avoid direct sunlight;
  • Do not transport the generator set on rough road for long time.

TROUBLESHOOTING

Problem Possible Causes Probable Solutions
Engine will not start FUEL RELATED:

1.No fuel in tank or fuel valve closed.
2.Choke not in START position, cold engine.
3.Gascene with more than 10% ethanol used. (E15. E20. E85. etc.)
4.Low quality or deteriorated. old gasoline.
5.Carburetor not primed.
6.Dilly fuel passageways.
7.Carburetor needle stuck. Fuel can be smelled in the air.
8.Too much fuel In chamber. This can be caused by the carburetor needle sticking.
9.Clogged Fuel Filter.| FUEL RELATED:
1.Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline and open fuel valve.
Do not use gasoline with more than
10% ethanol (E15, E20, ESL etc.).
2.Move Choke to START position.
3.Clean out ethanol rich gasoline from fuel system. Replace components damaged by ethanol. Use fresh 87+ octane stabilizer-treated unleaded gasoline only. Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).
4.Use fresh 87+ octane stabilizer-treated unleaded gasoline.
Do not use gasoline with more than 10% ethanol (E15, E20, ESS, etc.).
5.Pull on Starter Handle to prime.
6.Clean out passageways using fuel additive. Heavy deposits may require further cleaning
7.Gently tap side of carburetor float chamber with screwdriver handle.
8.Turn Choke to RUN position. Remove spark plug one pull the start handle several times to air out the chamber. Reinstall spark plug and set Choke to START position.
9.Replace Fuel Filter.
IGNITION (SPARK) RELATED:
1.Power Switch at OFF position.
2.Spark plug cap not connected securely.
3.Spark plug electrode wet or dirty.
4.Incorrect spark plug gap.
5.Spark plug cap broken.
6.Circuit breaker tripped (electric start models only).
7.Incorrect spark timing or faulty ignition system.| IGNITION (SPARK) RELATED:
1.Turn Power Switch to ON.
2.Connect spark plug cap properly.
3.Clean spark plug.
4.Correct spark plug gap.
5.Replace spark plug cap.
6.Reset circuit breaker. Check winng and starter motor if breaker continues to flip.
7.Have qualified technician diagnose/ repair ignition system.
COMPRESSION RELATED:
1.Cylinder not lubricated. Problem after long storage periods.
2.Loose or broken spark plug. (Hissing noise will occur when trying to start.)
3.Loose cylinder head or damaged head gasket. (Hissing noise will occur when trying to start.)
4.Engine valves or tappets mks-adjusted or stuck.| COMPRESSION RELATED:
1.Pour tablespoon of oil Into spark plug hole. Crank engine a few times and try to start again.
2.lighten spark plug.
If that does not work, replace spark plug. II problem persists. may have head gasket problem. see #3.
3.lighten head. If that does not remedy problem, replace head gasket.
4.Have qualified technician adjust/ repair valves and lappets.
ENGINE OIL RELATED:
1.Low engine oil.
2.Engine mounted on slope. triggering low oil shutdown.| ENGINE OIL RELATED:
1.Fill engine al to proper level. Check engine oil before EVERY use.
2.Operate engine on level surface. Check engine oil level.
SPARK ARRESTOR RELATED:
1. Spark Arrestor clogged with soot.| SPARK ARRESTOR RELATED:
1. Clean and replace Spark Arrestor.
Problem| Possible Causes| Probable Solutions
---|---|---
Engine misfires| 1.Spark pug cap loose.
2.Incorrect spark plug gap or damaged spark plug.
3.Defective Spark plug cap.
4.Old or low quality gasoline.
5.Incorrect compression.| 1.Check Cap and wire connections.
2.Re-gap or replace spark plug.
3.Replace Spark plug cap.
4.Use only fresh 87+ octane stabilizer-treated unleaded gasoline. Do not use gasoline with more than 10% ethanol (E15, E20, E85, etc.).
5.Diagnose and repair compression. (Use Engine will not start: COMPRESSION RELATED section.)
Engine Stops suddenly| 1.Carbon Monoxide level high. Red light on Carbon Monoxide Sensor illuminates.
2.CO Sensor Alarm flashes yellow continually shortly alter starting.
3.CO Sensor Alarm flashes yellow continually after longer period of operation,
4.Low oil shutdown.
5.Fuel tank empty or full of impure or low Quality gasoline.
6.Defective fuel tank cap creating vacuum, preventing proper fuel flow.
7.Faulty magneto.
8.Disconnected or improperly
connected spark plug Cap.| 1.Leave area immediately and allow area to ventilate thoroughly. Only operate generator outside.
2.Carbon monoxide Senile( malfunction. Sens”‘ needs service.
Do not use the Generator
until the sensor is working properly.
3.Make sure to operate generator within rated ambient temperature: maintain minimise 5 ft. clearance from all sides.
4.Fill engine 041 to proper level. Check engine oil before EVERY use.
5.Fill fuel tank with fresh 87• octane stabilizer treated unleaded gasoline.
Do not use gasoline with more than 10%
ethanol (E15. E20, E85. etc.).
6.Test/replace fuel tank cap.
7.Have qualified technician service magneto.
8.Secure spark plug cap.
Engine StepS when under heavy load| 1.Dirty air filler
2.Engine running cold.| 1.Clean element.
2.Mom engine to warm up prior to operating equipment.
Engine knoCks| 1.Old or low quality gasoline.
2.Engine overloaded.
3.Incorrect spark liming. deposit buildup. worn engine. or other b
mechanical problems.| I Fill fuel tank with fresh 87+ octane stabilizer- treated
unleaded gasoline.
th
Do not use gasoline with more an
10% ethanol (E15, E20, E85, etc.).
2.Do not exceed equipment’s load rating.
3.Have qualified technician diagnose and service engine.
Engine backfires| 1.Impure or low quality gasoline.
2.Engine too cold.
3.Intake valve stuck or overheated engine.
4.Incorrect timing.| 1.Fill fuel tank with fresh 87+ octane stabilizer-treated unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85. etc.).
2.Use cold weather fuel and oil additives
to prevent backfiring.
3.Have qualified technician diagnose and service engine.
4.Check engine timing.
Attached device doesn’t have power| 1.Device not plugged in properly.
2.Circuit Breaker tripped.
3.Product needs service.| 1.Turn off and unplug the device. then plug it back in again and tum on.
2.Turn off and unplug device reset Circuit Breaker, plug in Cievira, and tum on.
3.Have product repaired.
Attached device begins to operate abnormally| 1.Problem with device.
2.Rated load capacity exceeded.| 1.Immediately unplug device.
Have device repaired by a qualified
technician, or replace device.
2.Lower the number of items plugged into the generator to stay within the rated capacity. Or use a more powerful generator.

TECHNICAL PARAMETERS

Item GM6000XIE
Rated Power (kW) 5.
Max. Power (kW) 6.0
Engine Model 180F/P-2
Stroke x Bore (mm) 80×62
Engine Type 4-stroke
Displacement (cc) 312
Gas Distribution Mode OHV
Cooling Mode Forced cooling wind
Rated Speed (RPM) 3600
Starting Method Recoil start
Fuel Tank Volume (gal) 4.
Fuel Type and Grade Vehicle-use unleaded gasoline
Lubricating Oil Capacity (gal) 0.21
Lubncating Oil Model SAE 10W/30
Noise dB (at 7m)(25% load) 70
Rated Voltage (V) 120/240
Rated Frequency (Hz) 60
Rated Power Factor 1
Phase Number Single phase
Run Time @ 25% (h) 13
Overall Dimension (in.) 22.2×18.1×17.7
Net Weight (lb.) 107.

CIRCUIT DIAGRAM

GM6000XiE SCHEMATICSGENMAX 5250 Running Watts Portable Inverter Generator -
Figrue 46

CHOOSING A GENERATOR

GENMAX 5250 Running Watts Portable Inverter Generator - Figrue
47GENMAX 5250 Running Watts Portable
Inverter Generator - Figrue 48

In production management, based on orderly, efficient, scientific principles. trying to do as better as possible in product design, development, production, inspection,etc. to  make our production can keep orderly . And will continue to make improvement to make sure that keep the competitiveness.
Welcome friends at home and abroad to visit and guide, work together to create brilliant.

Caojie Industrial Park,Hechuan District,Chongqing
Phone 866-960-2920
warrantiessmallengines@gmail.com
E-mail
http://www.genmaxpower.com/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals