GENMAX GM9000iE Portable Inverter Generator User Manual
- June 9, 2024
- GENMAX
Table of Contents
GM9000iE Portable Inverter Generator
R
GENMAX GENERATOR
INVERTER GENERATOR USER’S MANUAL
GM9000iE
Portable Inverter Generator
7600 Running Watts | 9000 Peak Watts
GM9000iED/GM9000iEDC
Portable Inverter Generator
7600(GAS.)/7200(LPG) Running Watts | 9000(GAS.)/8550(LPG) Peak Watts
WARNING: SAVE THIS MANUAL FOR FUTURE REFERENCE
This manual contains important information regarding safety. Operation,
maintenance and storage of this product. Before use, read carefully and
understand all cautions, warnings, instructions and product labels. Failure to
do so could result in serious personal injury and/or property damage.
DISCLAIMERS: All information, illustrations and specifications in this manual
are based on the latest information available at the time of publishing. The
illustrations used in this manual are intended as representative reference
views only. Moreover, because of our continuous product improvement policy, we
may modify information, illustrations and/or specifications to explain and/or
exemplify a product, service or maintenance improvement. We reserve the right
to make any change at any time without notice. Some images may vary depending
upon which model is shown.
ALL RIGHTS RESERVED: No part of this publication may be reproduced or used in
any form by any means – graphic, electronic or mechanical, including
photocopying, recording, taping or information storage and retrieval systems –
without the written permission of CHONGQING DINKING POWER MACHINERY CO., LTD
This manual contains important instructions for operating this inverter
generator. For your safety and the safety of others, be sure to read this
manual thoroughly before operating the generator. Failure to properly follow
all instructions and precautions can cause you and others to be seriously hurt
or killed.
UNPACKING
Always have assistance when lifting the generator. The generator is heavy;
lifting it could cause bodily harm.
Avoid cutting on or near staples to prevent personal injury.
WHAT COMES IN THE BOX
Spark Plug Socket Wrench (1) Owner Manual (1) Warranty Information (1) Funnel
(1) Duplex plug (1) Four-prong plug (1) Industrial plug (1) Remote Control Key
(1) LPG Hose (GM9000iED/GM9000iEDC only)(1)
Tools required – box cutter or similar device.
1. Carefully cut the packing tape on top of the carton.
2. Remove socket wrench, oil and funnel and save for later.
3. Carefully cut two sides of the carton to remove the generator.
1
LIMITED WARRANTY
1. DURATION : One (1) year from the date of purchase by the original
purchaser ( retail customer ) on products used solely for consumer
applications; if a product is used for business, commercial, or industrial
applications, the warranty per iod will be limited to ninety (90) days from
the date of purchase.
2. WHO GIVES THIS WARRANTY (WARRANTOR): CHONGQING DINKING POWER MACHINERY
CO., LTD
3. WHO RECEIVES THIS WARRANTY(PURCHASER):The original purchaser (other than
for purposes of resale) of the Genmax’s inverter.4. WHAT PRODUCTS ARE COVERED
BY THIS WARRANTY: Any portable generator supplied or manufactured by
Warrantor.5. WHAT IS COVERED UNDER THIS WARRANTY: Substantial defects on
material and workmanship which occur within the durat ion of the warranty
period.
6. WHAT IS NOT COVERED UNDER THIS WARRANTY: A. Transportation changes for s
ending the product to Warrantor or its authorized service representative for
warranty service, or for shipping repaired or replacement products back to the
customer; these charges must be borne by the customer. B. Damages caused by
abuse, accident, shipping, misuse, overloading, modification, and the effects
of corrosion, erosion and normal wear and tear. C. Warranty is voided if the
customer fails to install, maintain and operate the product in accordance with
the instructions and recommendations set forth in the owner’s manual(s), or if
the product is used as rental equipment. D. Pre-delivery service, i.e.
assembly, oil or lubricants, and adjustment. E. Items or service that are
normally required to maintain the product, i.e. lubricants and filters. F.
Warrantor will not pay for repairs or adjustments to the product, or for any
costs or labour, performed without Warrantor’s prior authorization.
EXCLUSIONS AND LIMITATIONS : Warrantor makes no other warranty of any kind,
express or implied. Implied warranties, including warranties of
merchantability and of fitness for a particular purpose, are hereby
disclaimed. This warranty service described above is the exclusive remedy
under this warranty; liability for incidental and consequential damages is
excluded to the extent permitted by law. 7. RESPONSIBILITIES OF PURCHASER
UNDER THIS WARRANTY:
A. The purchaser must provide dated proof of purchase and must notify
Warrantor within the warranty period. B. Deliver or ship the serviced
generator or component to the nearest Warrantor’s authorized service
representative. Freight costs, if any, must be norne by the purchaser. 8. HAVE
QUESTIONS? Email: warrantiessmallengines@gmail.com Phone:
866-960-2920
WARRANTY CARD
Name: ___ Model Number:
Street Address: ___ Serial Number:__
City, State, ZIP:____ Date Purchased:
Country: __ Purchased From:____
Phone Number: ___
R
E-Mail: ___
2
TABLE OF CONTENTS
LIMITED WARRANTY
2
SAFETY WARNING
4
SAFETY INSTRUCTIONS
5
NAMES OF COMPONENTS
7
CONTROL FUNCTIONS
8
PREPARATIONS
11
1.Fuel…………………………………………………………………………………………………………………………..11 2.Oil……………………………………………………………………………………………………………………………..11 3.Pre-operation inspection………………………………………………………………………………………………12
STARTING UP THE GENERATOR
13
SHUTTING DOWN THE GENERATOR
16
USING THE GENERATOR
17
1.Service environment of the generator……………………………………………………………………………17 2.Generator wiring…………………………………………………………………………………………………………17 3.Generator grounding…………………………………………………………………………………………………..18
SERVICE AND MAINTENANCE
19
1.Spark plug inspection…………………………………………………………………………………………………20 2.Adjustment of the carburetor………………………………………………………………………………………..21 3.Replacement of oil……………………………………………………………………………………………………..21 4.Air filter……………………………………………………………………………………………………………………..22 5.Fuel filter screen…………………………………………………………………………………………………………23
STORAGE AND TRANSPORT
24
1.Generator storage………………………………………………………………………………………………………24
2.Generator transport…………………………………………………………………………………………………….25
TROUBLESHOOTING
26
TECHNICAL PARAMETERS
27
CIRCUIT DIAGRAM
28
CHOOSING A GENERATOR
31
3
SAFETY WARNING
Personal and property safeties of you and others are very vital. Please read
the Safety Warning in the User’s Manual and the decals of the generator set
carefully.The Safety Warning can alert you to those potential hazards that
could harm you and others. In front of each Safety Warning, there is one of
four words “DANGER” “WARNING”, “ATTENTION”, and “CAREFUL”. Details are as
follows:
Failure to follow the instruction will result in being in peril of your life or extremely serious injury.
Failure to follow the instruction will result in being in peril of your life or very serious injury.
Failure to follow the instruction will result in minor injury.
Failure to follow the instruction will result in the damage to your generator set and other properties.
CO TECHNICAL WARNING
CO DETECT technology monitors the accumulation of carbon monoxide (CO), a
poisonous gas produced by engine exhaust when the generator is running. If CO
Sensor detects unsafe elevated levels of CO gas, it automatically shuts off
the engine. CO Sensor is not a substitute for an indoor carbon monoxide alarm
or for safe operation. DO NOT allow engine exhaust fumes to enter a confined
area through windows, doors, vents or other openings. Generators must ALWAYS
be used outdoors, far away from occupied buildings with engine exhaust pointed
away from people and buildings. Meets the requirements of ANSI/PGMA G300-2018.
NEUTRAL FLOATING
For portable generators where the neutral is floating, the operator’s manual
shall include the following wording or equivalent:
The portable generator stator winding is isolated from the frame and from the
AC receptacle ground pin; and Electrical devices that require a connection
between one conductor pin and the grounded receptacle pin may not function
properly.
4
SAFETY INSTRUCTIONS
Before operating the generator, it will help you avoid accidents to read and
understand the Manual and familiarize yourself with the safe operation
procedures of the generator.
Please do not use indoors
Please do not use in humid environment
Please do not connect it to household appliances directly
Please do not smoke when refueling
Please do not spill when refueling
Please shut down the generator before refueling
5
SAFETY INSTRUCTIONS
SAFETY LABELS AND DECALS
6
NAMES OF COMPONENTS
LPG Port(GM9000iED only)
Fuel tank
Control panel
Drag rod Left enclosure Start handle Muffler
Wheel Right enclosure
7
CONTROL FUNCTIONS
12
14
10
11
CONTROL PANEL FEATURES GM9000iE
120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R): The outlet is capable of carrying
a maximum of 20 amps. USB Duplex: 5V DC that come in 1 amps and 2.1 amps.
Reset: If the inverter is overloaded, the reset breaker will trip. The engine
will continue to run, but there will be no output from the inverter. Unplug
the devices and reduce the load. Push in the reset breaker to reset it. Low
Idle: When turned to the ON position, the engine will sense the load needed
and run at a slower RPM to save fuel. Ground Terminal: The ground terminal is
used to externally ground the inverter. Fuel Switch: Open the fuel. AC
Breaker: If the inverter is overloaded, the reset breaker will trip to block
current. Main Switch: Manage battery power and shutdown. 120/240-Volt, 30-Amp
Outlet (L5-30): The outlet is capable of carrying a maximum of 30 amps. CO
Alarm: Shuts down the engine in the event of CO buildup.
13
One Push Start: Press this button, the engine can start and stop. Voltage
Selector: Switch between 120V and 240V voltage as required. 120/240 Volt AC,
50 Amp NEMA 14-50R Receptacle: Receptacle can supply a maximum of 50 Amps.
Parallel Connectors: To increase AC power output, the connector sockets are
used to connect the two same type generator with special paralleling cords.
The connector sockets is only used to the communication between the inverters,
they can not used for AC power output. The special paralleling cords shall be
purchase separately, and they shall be approved by certification body.
8
CONTROL FUNCTIONS
13
15
10
12
11
14
CONTROL PANEL FEATURES GM9000iED/GM9000iEDC
120-Volt, 20-Amp Duplex Outlet (NEMA 5-20R):
One Push Start: Press this button, the engine can
The outlet is capable of carrying a maximum of 20
start and stop.
amps. USB Duplex: 5V DC that come in 1 amps and 2.1 amps. Reset: If the inverter is overloaded, the reset breaker will trip. The engine will continue to run, but there will be no output from the inverter. Unplug the devices and reduce the load. Push in the reset breaker to reset it. Low Idle: When turned to the ON position, the engine will sense the load needed and run at a slower RPM to save fuel.
Voltage Selector: Switch between 120V and 240V voltage as required. 120/240 Volt AC, 50 Amp NEMA 14-50R Receptacle: Receptacle can supply a maximum of 50 Amps. Parallel Connectors: To increase AC power output, the connector sockets are used to connect the two same type generator with special paralleling cords. The connector sockets is only used to the communication between the inverters, they can not used for AC power output. The special paralleling
Ground Terminal: The ground terminal is used to externally ground the inverter.
cords shall be purchase separately, and they shall be approved by certification body.
Fuel Switch: Open the fuel.
AC Breaker: If the inverter is overloaded, the reset
breaker will trip to block current.
Main Switch: Manage battery power and
shutdown.
120/240-Volt, 30-Amp Outlet (L5-30): The outlet
is capable of carrying a maximum of 30 amps.
CO Alarm: Shuts down the engine in the event of
CO buildup.
LPG Inlet: Connects the LPG inlet to the LPG
hose/regulator.
9
CONTROL FUNCTIONS
DIGITAL DISPLAY CENTER
HOURS: Represents single run time, goes from 0 at each startup. HOURS: Represents total operation time of the generator. The two factors and are displayed alternately every 8 seconds. GASOLINE FUEL METER: Gasoline fuel level display. VOLTAGE: Voltage display: 120V and 240V switch every 16 seconds.
FREQUENCY: Frequency display. LOAD: Load power display. POWER: Green light means normal operation. OVERLOAD: Red light means the machine overload. LOW OIL: Red light means the amount of oil is too low.
10
PREPARATIONS
1 Fuel
DANGER
· Fuel is flammable and toxic, please read the Safety Instruction carefully
before refueling; · Do not fuel too full, otherwise fuel will spill after fuel
tank is warmed; · After refueling, confirm that the fuel tank cap has been
tightened.
ATTENTION
· After refueling, dry gasoline residue with a clean and soft cloth in time to
avoid damaging plastic enclosure; · Unleaded gasoline must be used, as leaded
gasoline can seriously damage internal parts of the generator;
Remove fuel tank cap, and add gasoline to red horizontal indicating line oil
level. Fuel tank capacity: 6.9gal
2 Oil
No oil is filled into this generator when being delivered. Do not start up the
generator without filling sufficient oil.
1. Please place the generator onto a horizontal plane surface;
2. Open the right exterior cover, unscrew oil
dipstick;
3. Fill in 0.3gal oil (SAE 10W/30 oil is
recommended, of which the grade is API standard Type SE or higher);
Don’t go over the scale
4. Cover the right panel.
11
PREPARATIONS
3 Pre-use Inspection
WARNING
Even if the generator is not in service, its important component may suddenly
fails. Before the generator is started up, if any of following components is
unable to work properly, please inspect and repair carefully. Tip: The
condition of the generator shall be inspected before using every time. Pre-
operation inspection Fuel · Check fuel level in fuel tank of the generator,
and fuel it if necessary. Oil · Check oil level of the generator, and fill oil
if necessary; · Check whether there is oil leaking. Abnormal conditions during
operation · Check operating condition of the generator; · If there is any
need, please do not hesitate to consult your dealer.
12
STARTING UP THE GENERATOR
GM9000iE Startup Procedure
1. Remove the load from all output ends;
2. Connect battery line before first use:
1. Remove the left panel cover; 2. Connect the positive and negative
electrodes of the battery.
3. Turn the fuel switch clockwise to “ON”;
4. Press the LOW IDLE switch to “OFF”;
5. Press the main switch to “ON”;
6. Select Boot Mode:
a. Hand Starting: Pull the starting handle to start the generator. b. One
Button to Start: Press the one-click start button to start the generator. c.
Remote Start: Press the “START” button on the remote control to start the
generator.
a.
b.
c.
7. Plug in after started.
13
STARTING UP THE GENERATOR
GM9000iED/GM9000iEDC Startup Procedure
1. Remove the load from all output ends;
2. Connect battery line before first use:
1. Remove the left panel cover; 2. Connect the positive and negative
electrodes of the battery.
3. Select the Fuel:
a. Gasoline: Turn the fuel source switch to gasoline.
b. LPG: 1. Connect the LPG hose to the LPG tank; 2. Tighten the other end of the LPG hose to the generator intake; 3. Turn the fuel source switch to LPG.
4. Press the LOW IDLE switch to “OFF”; 5. Press the main switch to “ON”;
14
STARTING UP THE GENERATOR
6. Select Boot Mode:
a. Hand Starting: Pull the starting handle to start the generator. b. One
Button to Start: Press the one-click start button to start the generator. c.
Remote Start: Press the “START” button on the remote control to start the
generator.
a.
b.
c.
7. Plug in after started.
Remote Control Pairing 1. Long press the start button for more than 5 seconds until the button red indicator is on; 2. Press any key on the remote control; 3. The red indicator of the start button will blink two or three times and then turns off, Remote start pairing is successful. Tip: The remote control delivered with the generator has been paired successfully.
3.1
3.2
15
SHUTTING DOWN THE GENERATOR
1. Unplug the power cord;
2. Select Stop Mode:
a.
b.
a. One Button to Start: Press the one-click start
button to turn off the generator.
b. Remote Start: Press the “STOP” button on
the remote control to turn off the generator.
3. Press the main switch to “OFF”;
4. Turn off gasoline or LPG.
16
USING THE GENERATOR
1 Service environment of the generator
· Applicable temperature: -5°C ~ 40°C; · Applicable humidity: below 95%; ·
Applicable altitude: regions below 1,500 m (It shall be used by reducing power
in regions above 1,000 m). Standard atmospheric condition · Ambient
temperature Tr: 298k (25°C) · Relative air humidity r: 30% · Absolute
atmospheric pressure Pr: 100kPa When actual environmental condition is
inconsistent with the condition of output power of the generator set: · Every
5°C of increase in ambient temperature will reduce the power of generator by
about 2%. · Every 30% of increase in relative humidity of air will reduce the
power of generator by about 1.5%. · Every 300 m rising of ASL will reduce the
power the generator by about 4.5%.
2 Generator wiring
· When the generator is connected to household power source as a backup power
supply, the connection shall be carried out by a professional electrician or a
person familiar with electricity. · After connecting the load to the
generator, check carefully whether electrical connection is safe and reliable.
Improper electrical connection may cause generator damage, burning or fire. ·
Avoid connecting this generator to commercial power outlet. · When extending
the cable, be sure not to exceed its length. 60m cross-section area is 1.5mm²
100m cross-section area is 2.5mm² · The appearance of extension cable shall be
protected by a layer of tough and elastic rubber cover (IEC25) or other
substitutes.
OK
OK
17
USING THE GENERATOR
Connection of AC power
WARNING
All electrical equipment shall be disconnected before inserting the plug.
ATTENTION
· Make sure that all electrical equipment, including wires and plugs, are in
good condition before connecting to the generator; · Make sure that all loads
driven by the generator are within rated load range; · Make sure that load
current is within rated current range of rated socket. Tip: Make sure that the
generator set is grounded, and if electrical equipment requires grounding, the
generator set must be grounded. Start up the engine; Turn energy-saving switch
to “ON”; Insert the plug into AC outlet; Make sure that AC indicator is lit
up; Switch on electrical equipment. Tip: Before increasing engine speed,
energysaving switch must be switched to “OFF”. If the generator set supplies
power to multi loads or electrical equipment, start from large to small
according to the size of each electrical equipment.
3 Generator grounding
In order to prevent any damage to the generator caused by electric shock or
improper electrical application, it is recommended that the generator is
grounded with good conductor with insulating sheath.
Please use grounding wire with sufficient electrical energy capacity; Connect
one end of grounding wire reliable to grounding bolt on control panel of the
generator set; Insert grounding body (iron rod with a diameter of 5 ~ 10mm)
200mm below into the earth and lead it out with conductor; Connect the other
end of the grounding wire reliable to the led wire of grounding body.
18
SERVICE AND MAINTENANCE
Good maintenance and service is the best guarantee for safe, economical and
zero-failure operation. It also contributes to environmental protection.
In order to keep the generator in good condition, you must inspect and
maintain it regularly. The maintenance schedule is as follows:
Maintenance cycle Each
Item
Engine oil
Check-fill
Replace
Gearbox gear
Check oil
Oil (if any)
Replace
Air cleaner element
Inspection
Clean
Replace
Settling cup (if any) Clean
Spark plug
Clean-adjust
Spark eliminator Clean
Idle speed (if any)**
Check-adjust
First in 1 month or 20 hours
Then every three months or every
50 hours
100 hours per year or use
Valve clearance** Check-adjust
Fuel tank and
fuel filter***
Clean
Fuel line
Cylinder head, piston
Inspection
Remove carbon deposit**
Every two yeara (Please replace if ecessary)
Displacement < 225cc, every 125 hours; displacement capacity 225cc, every 250
hours.
- These items shall be replaced if necessary; ** These items shall be maintained by the dealer authorized by the Company, unless the user has proper tools and maintenance ability.
ATTENTION
· If it often works under high temperature or high load, oil shall be changed
every 25 hours; · If it often works in dusty or harsh environment, air cleaner
element shall be cleaned every 10 hours. If necessary, the air cleaner element
shall be replaced every 25 hours; · It shall be maintained on spot-inspection
cycle and time, whichever is earlier; · If maintenance cycle time has elapsed,
perform the maintenance as soon as possible as per the table above.
19
SERVICE AND MAINTENANCE
WARNING
Please shut down the engine first before performing any maintenance. The
engine shall be placed in a horizontal position. In order to prevent the
engine from starting up, separate spark plug cap shall be separated from spark
plug.
Do not use it indoors or use it in a tunnel, cave or other places ventilated
poorly. Make sure that work area is well ventilated. Exhaust gas from the
engine contains toxic gases, carbon oxides, and the inhalation can cause
shock, loss of consciousness, and even death.
1 Spark plug inspection
Spark plug is an important part of the generator, which must be inspected
regularly.
1. Remove the left panel cover, and remove the
high voltage pack;
2. Insert the screwdriver into the sleeve, to screw it counterclockwise, and
then
remove the spark plug;
3. Check whether there is discoloration, and remove carbon deposits.Check
whether there is little pale to moderate brown on ceramic cores around center
electrode of the spark plug;
4. Check the model of spark plug and clearance.
Standard spark: BPR6ES Spark plug gap: 0.7-0.8mm
0.7~0.8mm
Tip: The spark plug clearance is required to be measured by line thickness gauge, which shall be adjusted if necessary.
20
SERVICE AND MAINTENANCE
5. Install the spark plugs in reverse order of removal.
Spark cold torque: 22.5±2.5 N.m
Tip: If there is no torque wrench when installing the spark plug, a better
estimation method is to screw it 1/4-1/2 turns by force after screwing it in
place, but the spark plug shall be screwed to specified torque as soon as
possible.
2 Adjustment of the carburetor
The carburetor is an important components of the engine. The adjustment shall
be carried out by a dealer with professional knowledge, professional data and
equipment, to ensure that the adjustment is proper.
3 Replacement of oil
WARNING
Do not drain the oil immediately after turning off the generator. Oil
temperature is very high, when operating, take care to avoid scalding.
1. Put the generator on a horizontal plane, start the generator, run it for a
few minutes to make it warm, then
turn off the engine;
2. Open the right exterior cover, find the bolt that
put the oil in;
3. 1. Remove the rubber plug;
2. Remove drain oil rubber plug; 3. Use containers to catch waste oil,
unscrew the drain oil bolt; 4. Tighten the drain bolt after the waste oil is
discharged clean, cover the rubber plug.
21
SERVICE AND MAINTENANCE
4. Unscrew oil dipstick;
5. Refill oil to a proper level, tighten oil dipstick,
cover external cover plate and tighten the knob. Recommended oil: SAE S10W/30
Oil grade: API standard Model SJ or higher Volume: 0.3gal
4 Air filter
Dirty air cleaner may prevent air from flowing into the carburetor. In order
to prevent failure of the carburetor, please maintain air cleaner regularly.
If being used in a dusty environment, it shall be maintained frequently.
1. Remove screws , to remove cover plate of air
cleaner ;
2. Clean foam cleaner element with cleaning solvent and blow it dry, Put a
few
drops of oil on the filter element.
ATTENTION
Be sure not to twist the foam cleaner element forcibly to avoid damage.
3. Put foam cleaner element into air cleaner;
Tip: Make sure that the surface of foam cleaner element is in close contact
with air cleaner, and there shall be no gap leaking air. Be sure not to start
the engine before air cleaner is assembled, because it will generate excessive
toxic gas and wear the cylinder;
4. 1. Reassemble empty air cleaner cap back to original position, and tighten
screws; 2. Assemble left outer cover and tighten bolts.
22
SERVICE AND MAINTENANCE
5 Fuel filter screen
WARNING
Be sure not to open fuel tank of the generator in a place where smoking or
with flame. 1. Remove fuel tank cap and fuel tank filter screen. 2. Clean fuel
tank filter screen with gasoline. 3. Wipe filter screen dry, and put it back
into fuel tank. 4. Reassemble fuel tank cap.
ATTENTION
Be sure to screw fuel tank cap tight.
23
STORAGE AND TRANSPORT
1 Generator storage
If it is stored long-term, in order to prevent aging, you shall take some
storage measures.
1. Shut down generator. 2. Open fuel tank cap, to take out fuel filter
screen.
Pump all fuel in fuel tank into special fuel tank, and then reassemble fuel
tank cap back.
3. Start up the engine to burn off fuel in the carburetor, and then shut it
down.
Tip: Do not connect any electrical equipment. Running time of the engine
depends on remaining fuel in the fuel tank.
4. Open generator left exterior cover and enter carburetor. Locate the clear
plastic hose from the carburetor and place a suitable container under it to
capture the drained fuel.
5. Loosen the carburetor drain screws until you see fuel draining from the
carburetor.
6. Allow fuel to drain into the container and tighten the drain screws on the
carburetor. Install the engine service panel.
7. Unscrew oil dipstick, and drain oil in the crankcase off. Fill new oil to
upper oil limit, and then assemble
oil dipstick.
24
STORAGE AND TRANSPORT
8. Gently pull startup handle until you feel resistance, allowing both inlet
valve
and exhaust valve to be closed.
9. Disconnect the battery cable.
10. Place the generator set in a clean and dry area. 2 Generator transport
· When the generator set is transported, it shall be ensured that there is no
fuel spilling; · Do not fill excessive fuel into fuel tank; · Do not run the
generator, and avoid direct sunlight; · Do not transport the generator set on
rough road for long time.
25
TROUBLESHOOTING
26
TROUBLESHOOTING
27
TECHNICAL PARAMETERS
Item Rated Power (kW) Max. Power (kW) Engine Model Stroke x Bore (mm) Engine Type Displacement (cc) Gas Distribution Mode Cooling Mode Rated Speed (RPM) Starting Method Fuel Tank Volume (gal) Fuel Type and Grade Lubricating Oil Capacity (gal) Lubricating Oil Model Noise dB (at 7m)(25% load) Rated Voltage (V) Rated Frequency (Hz) Rated Power Factor Phase Number Run Time @ 25% (h) Overall Dimension (in.) Net Weight (lb.)
GM9000iE
GM9000iED/GM9000iEDC
7.6
7.6(GAS.)/7.2(LPG)
9.0
9.0(GAS.)/8.55(LPG)
460i
460i
92×69
92×69
4-stroke 458
4-stroke 458
OHV
OHV
Forced cooling wind
3600
3600
Recoil start/Electrical start/Remote start
6.9
6.9
Vehicle-use unleaded gasoline
0.3
0.3
SAE 10W/30
SAE 10W/30
62
62
120/240
120/240
60
60
1
1
Single phase
Single phase
14
14
30.9×22.6×29.3
30.9×22.6×29.3
233.7
243.6
28
GM9000iE SCHEMATICS
CIRCUIT DIAGRAM
29
CIRCUIT DIAGRAM
GM9000iED/GM9000iEDC SCHEMATICS
30
R
CHOOSING
A GENERATOR
1
31
In production management, based on orderly, efficient, scientific principles.
trying to do as better as possible in product design, development, production,
inspection,etc. to make our production can keep orderly . And will continue to
make improvement to make sure that keep the competitiveness. Welcome friends